CWE-798
Use of Hard-coded Credentials
Description
The product contains hard-coded credentials, such as a password or cryptographic key.
Hierarchy (View 1000)
Related attack patterns (CAPEC)
CAPEC-191 · CAPEC-70
CVEs mapped to this weakness (1,842)
page 45 of 93| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2020-1716 | Hig | 0.57 | 8.8 | 0.01 | May 28, 2021 | A flaw was found in the ceph-ansible playbook where it contained hardcoded passwords that were being used as default passwords while deploying Ceph services. Any authenticated attacker can abuse this flaw to brute-force Ceph deployments, and gain administrator access to Ceph… | ||
| CVE-2021-28111 | Hig | 0.57 | 8.8 | 0.03 | May 20, 2021 | Draeger X-Dock Firmware before 03.00.13 has Hard-Coded Credentials, leading to remote code execution by an authenticated attacker. | ||
| CVE-2021-27392 | Hig | 0.57 | 8.8 | 0.01 | Apr 22, 2021 | A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019… | ||
| CVE-2021-27438 | Hig | 0.57 | 8.8 | 0.01 | Mar 25, 2021 | The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1). | ||
| CVE-2021-27254 | Hig | 0.57 | 8.8 | 0.00 | Mar 5, 2021 | This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of NETGEAR R7800. Authentication is not required to exploit this vulnerability. The specific flaw exists within the apply_save.cgi endpoint. This issue results from the use of… | ||
| CVE-2020-9306 | Hig | 0.57 | 8.8 | 0.01 | Feb 18, 2021 | Tesla SolarCity Solar Monitoring Gateway through 5.46.43 has a "Use of Hard-coded Credentials" issue because Digi ConnectPort X2e uses a .pyc file to store the cleartext password for the python user account. | ||
| CVE-2020-29375 | Hig | 0.57 | 8.8 | 0.01 | Nov 29, 2020 | An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. An low-privileged (non-admin) attacker can use a hardcoded password (4ef9cea10b2362f15ba4558b1d5c081f) to create an… | ||
| CVE-2020-26892 | Cri | 0.57 | 9.8 | 0.02 | Nov 6, 2020 | The JWT library in NATS nats-server before 2.1.9 has Incorrect Access Control because of how expired credentials are handled. | ||
| CVE-2020-5374 | Hig | 0.57 | 8.8 | 0.01 | Jul 14, 2020 | Dell EMC OpenManage Integration for Microsoft System Center (OMIMSSC) for SCCM and SCVMM versions prior to 7.2.1 contain a hard-coded cryptographic key vulnerability. A remote unauthenticated attacker may exploit this vulnerability to gain access to the appliance data for… | ||
| CVE-2020-7501 | Hig | 0.57 | 8.8 | 0.01 | Jun 16, 2020 | A CWE-798: Use of Hard-coded Credentials vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior) which could cause unauthorized read and write when downloading and uploading project or firmware into Vijeo Designer Basic and… | ||
| CVE-2020-3234 | Hig | 0.57 | 8.8 | 0.00 | Jun 3, 2020 | A vulnerability in the virtual console authentication of Cisco IOS Software for Cisco 809 and 829 Industrial Integrated Services Routers (Industrial ISRs) and Cisco 1000 Series Connected Grid Routers (CGR1000) could allow an authenticated but low-privileged, local attacker to… | ||
| CVE-2019-20656 | Hig | 0.57 | 8.8 | 0.00 | Apr 15, 2020 | Certain NETGEAR devices are affected by a hardcoded password. This affects D6200 before 1.1.00.36, D7000 before 1.0.1.74, PR2000 before 1.0.0.30, R6020 before 1.0.0.42, R6080 before 1.0.0.42, R6050 before 1.0.1.24, JR6150 before 1.0.1.24, R6120 before 1.0.0.48, R6220 before… | ||
| CVE-2019-10995 | Hig | 0.57 | 8.8 | 0.01 | Jan 14, 2020 | ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. | ||
| CVE-2018-18929 | Hig | 0.57 | 8.8 | 0.01 | Oct 29, 2019 | The Tightrope Media Carousel Seneca HDn Windows-based appliance 7.0.4.104 is shipped with a default local administrator username and password. This can be found by a limited user account in an "unattend.xml" file left over on the C: drive from the Sysprep process. An attacker… | ||
| CVE-2019-15867 | Hig | 0.57 | 8.8 | 0.02 | Sep 3, 2019 | The slick-popup plugin before 1.7.2 for WordPress has a hardcoded OmakPass13# password for the slickpopupteam account, after a Subscriber calls a certain AJAX action. | ||
| CVE-2019-15745 | Hig | 0.57 | 8.8 | 0.01 | Aug 29, 2019 | The Eques elf smart plug and the mobile app use a hardcoded AES 256 bit key to encrypt the commands and responses between the device and the app. The communication happens over UDP port 27431. An attacker on the local network can use the same key to encrypt and send commands to… | ||
| CVE-2019-9229 | Hig | 0.57 | 8.8 | 0.01 | Jul 20, 2019 | An issue was discovered on AudioCodes Mediant 500L-MSBR, 500-MBSR, M800B-MSBR and 800C-MSBR devices with firmware versions F7.20A to F7.20A.251. An internal interface exposed to the link-local address 169.254.254.253 allows attackers in the local network to access multiple… | ||
| CVE-2019-7225 | Hig | 0.57 | 8.8 | 0.03 | Jun 27, 2019 | The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool "Panel Builder 600" to flash a new interface and Tags (MODBUS coils) mapping to the HMI. These… | ||
| CVE-2019-7672 | Hig | 0.57 | 8.8 | 0.02 | Jun 5, 2019 | Prima Systems FlexAir, Versions 2.3.38 and prior. The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to escalate privileges. | ||
| CVE-2019-11947 | Hig | 0.57 | 8.8 | 0.03 | Jun 5, 2019 | A remote code execution vulnerability was identified in HPE Intelligent Management Center (IMC) PLAT earlier than version 7.3 E0506P09. |
- risk 0.57cvss 8.8epss 0.01
A flaw was found in the ceph-ansible playbook where it contained hardcoded passwords that were being used as default passwords while deploying Ceph services. Any authenticated attacker can abuse this flaw to brute-force Ceph deployments, and gain administrator access to Ceph…
- risk 0.57cvss 8.8epss 0.03
Draeger X-Dock Firmware before 03.00.13 has Hard-Coded Credentials, leading to remote code execution by an authenticated attacker.
- risk 0.57cvss 8.8epss 0.01
A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019…
- risk 0.57cvss 8.8epss 0.01
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
- risk 0.57cvss 8.8epss 0.00
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of NETGEAR R7800. Authentication is not required to exploit this vulnerability. The specific flaw exists within the apply_save.cgi endpoint. This issue results from the use of…
- risk 0.57cvss 8.8epss 0.01
Tesla SolarCity Solar Monitoring Gateway through 5.46.43 has a "Use of Hard-coded Credentials" issue because Digi ConnectPort X2e uses a .pyc file to store the cleartext password for the python user account.
- risk 0.57cvss 8.8epss 0.01
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. An low-privileged (non-admin) attacker can use a hardcoded password (4ef9cea10b2362f15ba4558b1d5c081f) to create an…
- risk 0.57cvss 9.8epss 0.02
The JWT library in NATS nats-server before 2.1.9 has Incorrect Access Control because of how expired credentials are handled.
- risk 0.57cvss 8.8epss 0.01
Dell EMC OpenManage Integration for Microsoft System Center (OMIMSSC) for SCCM and SCVMM versions prior to 7.2.1 contain a hard-coded cryptographic key vulnerability. A remote unauthenticated attacker may exploit this vulnerability to gain access to the appliance data for…
- risk 0.57cvss 8.8epss 0.01
A CWE-798: Use of Hard-coded Credentials vulnerability exists in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior) which could cause unauthorized read and write when downloading and uploading project or firmware into Vijeo Designer Basic and…
- risk 0.57cvss 8.8epss 0.00
A vulnerability in the virtual console authentication of Cisco IOS Software for Cisco 809 and 829 Industrial Integrated Services Routers (Industrial ISRs) and Cisco 1000 Series Connected Grid Routers (CGR1000) could allow an authenticated but low-privileged, local attacker to…
- risk 0.57cvss 8.8epss 0.00
Certain NETGEAR devices are affected by a hardcoded password. This affects D6200 before 1.1.00.36, D7000 before 1.0.1.74, PR2000 before 1.0.0.30, R6020 before 1.0.0.42, R6080 before 1.0.0.42, R6050 before 1.0.1.24, JR6150 before 1.0.1.24, R6120 before 1.0.0.48, R6220 before…
- risk 0.57cvss 8.8epss 0.01
ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface.
- risk 0.57cvss 8.8epss 0.01
The Tightrope Media Carousel Seneca HDn Windows-based appliance 7.0.4.104 is shipped with a default local administrator username and password. This can be found by a limited user account in an "unattend.xml" file left over on the C: drive from the Sysprep process. An attacker…
- risk 0.57cvss 8.8epss 0.02
The slick-popup plugin before 1.7.2 for WordPress has a hardcoded OmakPass13# password for the slickpopupteam account, after a Subscriber calls a certain AJAX action.
- risk 0.57cvss 8.8epss 0.01
The Eques elf smart plug and the mobile app use a hardcoded AES 256 bit key to encrypt the commands and responses between the device and the app. The communication happens over UDP port 27431. An attacker on the local network can use the same key to encrypt and send commands to…
- risk 0.57cvss 8.8epss 0.01
An issue was discovered on AudioCodes Mediant 500L-MSBR, 500-MBSR, M800B-MSBR and 800C-MSBR devices with firmware versions F7.20A to F7.20A.251. An internal interface exposed to the link-local address 169.254.254.253 allows attackers in the local network to access multiple…
- risk 0.57cvss 8.8epss 0.03
The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool "Panel Builder 600" to flash a new interface and Tags (MODBUS coils) mapping to the HMI. These…
- risk 0.57cvss 8.8epss 0.02
Prima Systems FlexAir, Versions 2.3.38 and prior. The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to escalate privileges.
- risk 0.57cvss 8.8epss 0.03
A remote code execution vulnerability was identified in HPE Intelligent Management Center (IMC) PLAT earlier than version 7.3 E0506P09.