VYPR
Vendor

Draeger

Products
6
CVEs
8
Across products
22
Status
Private

Products

6

Recent CVEs

8
  • CVE-2021-28112HigMay 20, 2021
    risk 0.57cvss 8.8epss 0.02

    Draeger X-Dock Firmware before 03.00.13 has Active Debug Code on a debug port, leading to remote code execution by an authenticated attacker.

  • CVE-2021-28111HigMay 20, 2021
    risk 0.57cvss 8.8epss 0.03

    Draeger X-Dock Firmware before 03.00.13 has Hard-Coded Credentials, leading to remote code execution by an authenticated attacker.

  • CVE-2019-25718HigJun 1, 2026
    risk 0.55cvss 8.4epss 0.00

    Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the…

  • CVE-2018-19012HigJan 28, 2019
    risk 0.51cvss 7.8epss 0.00

    Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Via a specific dialog it is possible to break out of the kiosk mode and reach the underlying operating system. By breaking out of the kiosk…

  • CVE-2019-25716MedJun 1, 2026
    risk 0.42cvss 6.5epss 0.00

    Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient…

  • CVE-2018-19014MedJan 28, 2019
    risk 0.42cvss 6.5epss 0.01

    Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. Log files are accessible over an unauthenticated network connection. By accessing the log files, an attacker is able to gain insights about…

  • CVE-2018-19010MedJan 28, 2019
    risk 0.42cvss 6.5epss 0.01

    Drager Infinity Delta, Infinity Delta, all versions, Delta XL, all versions, Kappa, all version, and Infinity Explorer C700, all versions. A malformed network packet may cause the monitor to reboot. By repeatedly sending the malformed network packet, an attacker may be able to…

  • CVE-2019-25717MedJun 2, 2026
    risk 0.28cvss 4.3epss 0.00

    Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired…