Vendor
Products
21
CVEs
12
Across products
35
Status
Private
Products
21- 4 CVEs
- 3 CVEs
- 3 CVEs
- 2 CVEs
- 2 CVEs
- 2 CVEs
- 2 CVEs
- 2 CVEs
- 2 CVEs
- 2 CVEs
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
Recent CVEs
12| CVE | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|
| CVE-2017-7920 | Hig | 0.49 | 7.5 | 0.01 | Aug 7, 2017 | An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating. | |
| CVE-2017-7916 | Med | 0.42 | 6.5 | 0.00 | Aug 7, 2017 | A Permissions, Privileges, and Access Controls issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. The web application does not properly restrict privileges of the Guest account. A malicious user may be able to gain access to configuration information that should be restricted. | |
| CVE-2016-4524 | Med | 0.42 | 6.5 | 0.00 | Jun 10, 2016 | ABB PCM600 before 2.7 improperly stores OPC Server IEC61850 passwords in unspecified temporary circumstances, which allows local users to obtain sensitive information via unknown vectors. | |
| CVE-2016-4527 | Low | 0.21 | 3.3 | 0.00 | Jun 10, 2016 | ABB PCM600 before 2.7 improperly stores PCM600 authentication credentials, which allows local users to obtain sensitive information via unspecified vectors. | |
| CVE-2016-4511 | Low | 0.18 | 2.8 | 0.00 | Jun 10, 2016 | ABB PCM600 before 2.7 uses an improper hash algorithm for the main application password, which makes it easier for local users to obtain sensitive cleartext information by leveraging read access to the ACTConfig configuration file. | |
| CVE-2008-2474 | 0.04 | — | 0.53 | Sep 29, 2008 | Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface. | ||
| CVE-2012-0245 | 0.02 | — | 0.21 | Mar 9, 2012 | Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via a crafted (1) 0xA or (2) 0xE Netscan packet. | ||
| CVE-2024-4009 | 0.00 | — | 0.00 | Jun 5, 2024 | Replay Attack in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to capture/replay KNX telegram to local KNX Bus-System | ||
| CVE-2024-4008 | 0.00 | — | 0.00 | Jun 5, 2024 | FDSK Leak in ABB, Busch-Jaeger, FTS Display (version 1.00) and BCU (version 1.3.0.33) allows attacker to take control via access to local KNX Bus-System | ||
| CVE-2014-5430 | 0.00 | — | 0.00 | Nov 7, 2014 | Untrusted search path vulnerability in ABB RobotStudio 5.6x before 5.61.02 and Test Signal Viewer 1.5 allows local users to gain privileges via a Trojan horse DLL that is accessed as a result of incorrect DLL configuration by an optional installation program. | ||
| CVE-2013-5021 | 0.00 | — | 0.01 | Aug 6, 2013 | Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value. | ||
| CVE-2012-1801 | 0.00 | — | 0.00 | Apr 18, 2012 | Multiple stack-based buffer overflows in (1) COM and (2) ActiveX controls in ABB WebWare Server, WebWare SDK, Interlink Module, S4 OPC Server, QuickTeach, RobotStudio S4, and RobotStudio Lite allow remote attackers to execute arbitrary code via crafted input data. |