Vendor CVEs
Schneider Electric
All CVEs
880 total · sorted by risk| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2020-7482 | Med | 0.40 | 6.1 | 0.01 | Mar 23, 2020 | A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products' web server. | ||
| CVE-2020-7481 | Med | 0.40 | 6.1 | 0.01 | Mar 23, 2020 | A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products' web server. | ||
| CVE-2019-6853 | Med | 0.40 | 6.1 | 0.01 | Nov 20, 2019 | A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server. | ||
| CVE-2018-7834 | Med | 0.40 | 6.1 | 0.01 | May 22, 2019 | A CWE-79 Cross-Site Scripting vulnerability exists in all versions of the TSXETG100 allowing an attacker to send a specially crafted URL with an embedded script to a user that would then be executed within the context of that user. | ||
| CVE-2018-7804 | Med | 0.40 | 6.1 | 0.01 | Dec 17, 2018 | A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker's choosing. | ||
| CVE-2018-7797 | Med | 0.40 | 6.1 | 0.01 | Dec 17, 2018 | A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert 1.3 (formerly Power Manager), EcoStruxure Power SCADA Operation (PSO) 8.2 Advanced… | ||
| CVE-2018-7810 | Med | 0.40 | 6.1 | 0.01 | Nov 30, 2018 | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed… | ||
| CVE-2018-7786 | Med | 0.40 | 6.1 | 0.01 | Jul 3, 2018 | In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts. | ||
| CVE-2018-2641 | Med | 0.40 | 6.1 | 0.05 | Jan 18, 2018 | Vulnerability in the Java SE, Java SE Embedded component of Oracle Java SE (subcomponent: AWT). Supported versions that are affected are Java SE: 6u171, 7u161, 8u152 and 9.0.1; Java SE Embedded: 8u151. Difficult to exploit vulnerability allows unauthenticated attacker with… | ||
| CVE-2017-5157 | Med | 0.40 | 6.1 | 0.01 | Feb 13, 2017 | An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code. | ||
| CVE-2016-4513 | Med | 0.40 | 6.1 | 0.01 | Jun 26, 2016 | Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | ||
| CVE-2012-0930 | Med | 0.40 | 6.1 | 0.02 | Jan 28, 2012 | Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | ||
| CVE-2025-2002 | Med | 0.39 | 6.0 | 0.00 | Mar 12, 2025 | CWE-532: Insertion of Sensitive Information into Log Files vulnerability exists that could cause the disclosure of FTP server credentials when the FTP server is deployed, and the device is placed in debug mode by an administrative user and the debug files are exported from the… | ||
| CVE-2018-2618 | Med | 0.39 | 5.9 | 0.05 | Jan 18, 2018 | Vulnerability in the Java SE, Java SE Embedded, JRockit component of Oracle Java SE (subcomponent: JCE). Supported versions that are affected are Java SE: 6u171, 7u161, 8u152 and 9.0.1; Java SE Embedded: 8u151; JRockit: R28.3.16. Difficult to exploit vulnerability allows… | ||
| CVE-2025-9997 | Med | 0.38 | — | 0.00 | Sep 9, 2025 | CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session. | ||
| CVE-2025-9996 | Med | 0.38 | — | 0.01 | Sep 9, 2025 | CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session. | ||
| CVE-2025-6438 | Med | 0.38 | — | 0.00 | Jul 11, 2025 | A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause manipulation of SOAP API calls and XML external entities injection resulting in unauthorized file access when the server is accessed via the network using an application… | ||
| CVE-2024-8530 | Med | 0.38 | 5.9 | 0.01 | Oct 11, 2024 | CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause exposure of private data when an already generated “logcaptures” archive is accessed directly by HTTPS. | ||
| CVE-2024-37039 | Med | 0.38 | 5.9 | 0.01 | Jun 12, 2024 | CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request. | ||
| CVE-2022-34764 | Med | 0.38 | 5.9 | 0.01 | Jul 13, 2022 | A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service when parsing the URL. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module… | ||
| CVE-2022-34763 | Med | 0.38 | 5.9 | 0.00 | Jul 13, 2022 | A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and… | ||
| CVE-2022-34762 | Med | 0.38 | 5.9 | 0.01 | Jul 13, 2022 | A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized firmware image loading when unsigned images are added to the firmware image path. Affected Products: X80 advanced RTU Communication Module… | ||
| CVE-2022-24320 | Med | 0.38 | 5.9 | 0.01 | Feb 9, 2022 | A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All… | ||
| CVE-2022-24319 | Med | 0.38 | 5.9 | 0.01 | Feb 9, 2022 | A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All… | ||
| CVE-2021-22784 | Med | 0.38 | 5.7 | 0.12 | Jul 21, 2021 | A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system. | ||
| CVE-2021-22739 | Med | 0.38 | 5.9 | 0.01 | May 26, 2021 | Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is first configured. | ||
| CVE-2019-6830 | Med | 0.38 | 5.9 | 0.01 | Sep 17, 2019 | A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the controller. | ||
| CVE-2018-7803 | Med | 0.38 | 5.9 | 0.01 | May 22, 2019 | A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is… | ||
| CVE-2017-9968 | Med | 0.38 | 5.9 | 0.01 | Feb 12, 2018 | A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack. | ||
| CVE-2017-9965 | Med | 0.38 | 5.8 | 0.05 | Jan 2, 2018 | An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory traversal attack, an unauthorized person can view web server files. | ||
| CVE-2014-0759 | Med | 0.38 | 5.9 | 0.00 | Feb 28, 2014 | Unquoted Windows search path vulnerability in Schneider Electric Floating License Manager 1.0.0 through 1.4.0 allows local users to gain privileges via a Trojan horse application with a name composed of an initial substring of a path that contains a space character. | ||
| CVE-2020-7567 | Med | 0.37 | 5.7 | 0.00 | Nov 19, 2020 | A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221… | ||
| CVE-2018-3693 | Med | 0.37 | 5.6 | 0.08 | Jul 10, 2018 | Systems with microprocessors utilizing speculative execution and branch prediction may allow unauthorized disclosure of information to an attacker with local user access via a speculative buffer overflow and side-channel analysis. | ||
| CVE-2025-5743 | Med | 0.36 | 5.5 | 0.01 | Jun 10, 2025 | CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote control over the charging station when an authenticated user modifies configuration parameters on the web server. | ||
| CVE-2023-37200 | Med | 0.36 | 5.5 | 0.00 | Jul 12, 2023 | A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause loss of confidentiality when replacing a project file on the local filesystem and after manual restart of the server. | ||
| CVE-2023-25555 | Med | 0.36 | 5.6 | 0.01 | Apr 18, 2023 | A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. … | ||
| CVE-2023-1548 | Med | 0.36 | 5.5 | 0.00 | Apr 18, 2023 | A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above) | ||
| CVE-2022-37302 | Med | 0.36 | 5.5 | 0.00 | Sep 13, 2022 | A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior). | ||
| CVE-2022-34765 | Med | 0.36 | 5.5 | 0.01 | Jul 13, 2022 | A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA… | ||
| CVE-2022-0221 | Med | 0.36 | 5.5 | 0.01 | Apr 13, 2022 | A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could result in information disclosure when opening a malicious solution file provided by an attacker with SCADAPack Workbench. This could be exploited to pass data from local files to a… | ||
| CVE-2021-22809 | Med | 0.36 | 5.5 | 0.01 | Jan 28, 2022 | A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior | ||
| CVE-2021-22782 | Med | 0.36 | 5.5 | 0.00 | Jul 14, 2021 | Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack… | ||
| CVE-2021-22781 | Med | 0.36 | 5.5 | 0.00 | Jul 14, 2021 | Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack… | ||
| CVE-2020-28214 | Med | 0.36 | 5.5 | 0.01 | Dec 11, 2020 | A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 (all references, all versions), that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection… | ||
| CVE-2020-7529 | Med | 0.36 | 5.5 | 0.01 | Sep 16, 2020 | A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Transversal') vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place content in any unprotected folder on the target system using a crafted .RCZ file. | ||
| CVE-2020-7517 | Med | 0.36 | 5.5 | 0.00 | Jul 23, 2020 | A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to read user credentials. | ||
| CVE-2020-7495 | Med | 0.36 | 5.5 | 0.01 | Jun 16, 2020 | A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability during zip file extraction exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause unauthorized write access… | ||
| CVE-2018-7822 | Med | 0.36 | 5.5 | 0.00 | May 22, 2019 | An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting… | ||
| CVE-2018-7839 | Med | 0.36 | 5.5 | 0.00 | Feb 6, 2019 | A Cryptographic Issue (CWE-310) vulnerability exists in IIoT Monitor 3.1.38 which could allow information disclosure. | ||
| CVE-2017-9959 | Med | 0.36 | 5.5 | 0.00 | Sep 26, 2017 | A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system accepts reboot in session from unauthenticated users, supporting a denial of service condition. |
- risk 0.40cvss 6.1epss 0.01
A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could cause a Reflective Cross-site Scripting (XSS attack) when using the products' web server.
- risk 0.40cvss 6.1epss 0.01
A CWE-79:Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists Andover Continuum (All versions), which could enable a successful Cross-site Scripting (XSS attack) when using the products' web server.
- risk 0.40cvss 6.1epss 0.01
A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server.
- risk 0.40cvss 6.1epss 0.01
A CWE-79 Cross-Site Scripting vulnerability exists in all versions of the TSXETG100 allowing an attacker to send a specially crafted URL with an embedded script to a user that would then be executed within the context of that user.
- risk 0.40cvss 6.1epss 0.01
A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker's choosing.
- risk 0.40cvss 6.1epss 0.01
A URL redirection vulnerability exists in Power Monitoring Expert, Energy Expert (formerly Power Manager) - EcoStruxure Power Monitoring Expert (PME) v8.2 (all editions), EcoStruxure Energy Expert 1.3 (formerly Power Manager), EcoStruxure Power SCADA Operation (PSO) 8.2 Advanced…
- risk 0.40cvss 6.1epss 0.01
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 allowing an attacker to craft a URL containing JavaScript that will be executed…
- risk 0.40cvss 6.1epss 0.01
In Schneider Electric U.motion Builder software versions prior to v1.3.4, a cross site scripting (XSS) vulnerability exists which could allow injection of malicious scripts.
- risk 0.40cvss 6.1epss 0.05
Vulnerability in the Java SE, Java SE Embedded component of Oracle Java SE (subcomponent: AWT). Supported versions that are affected are Java SE: 6u171, 7u161, 8u152 and 9.0.1; Java SE Embedded: 8u151. Difficult to exploit vulnerability allows unauthenticated attacker with…
- risk 0.40cvss 6.1epss 0.01
An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code.
- risk 0.40cvss 6.1epss 0.01
Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
- risk 0.40cvss 6.1epss 0.02
Cross-site scripting (XSS) vulnerability in Schneider Electric Modicon Quantum PLC allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
- risk 0.39cvss 6.0epss 0.00
CWE-532: Insertion of Sensitive Information into Log Files vulnerability exists that could cause the disclosure of FTP server credentials when the FTP server is deployed, and the device is placed in debug mode by an administrative user and the debug files are exported from the…
- risk 0.39cvss 5.9epss 0.05
Vulnerability in the Java SE, Java SE Embedded, JRockit component of Oracle Java SE (subcomponent: JCE). Supported versions that are affected are Java SE: 6u171, 7u161, 8u152 and 9.0.1; Java SE Embedded: 8u151; JRockit: R28.3.16. Difficult to exploit vulnerability allows…
- risk 0.38cvss —epss 0.00
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.
- risk 0.38cvss —epss 0.01
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session.
- risk 0.38cvss —epss 0.00
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause manipulation of SOAP API calls and XML external entities injection resulting in unauthorized file access when the server is accessed via the network using an application…
- risk 0.38cvss 5.9epss 0.01
CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause exposure of private data when an already generated “logcaptures” archive is accessed directly by HTTPS.
- risk 0.38cvss 5.9epss 0.01
CWE-252: Unchecked Return Value vulnerability exists that could cause denial of service of the device when an attacker sends a specially crafted HTTP request.
- risk 0.38cvss 5.9epss 0.01
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service when parsing the URL. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module…
- risk 0.38cvss 5.9epss 0.00
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and…
- risk 0.38cvss 5.9epss 0.01
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized firmware image loading when unsigned images are added to the firmware image path. Affected Products: X80 advanced RTU Communication Module…
- risk 0.38cvss 5.9epss 0.01
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All…
- risk 0.38cvss 5.9epss 0.01
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All…
- risk 0.38cvss 5.7epss 0.12
A CWE-306: Missing Authentication for Critical Function vulnerability exists in C-Bus Toolkit v1.15.8 and prior that could allow an attacker to use a crafted webpage to obtain remote access to the system.
- risk 0.38cvss 5.9epss 0.01
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is first configured.
- risk 0.38cvss 5.9epss 0.01
A CWE-248: Uncaught Exception vulnerability exists IN Modicon M580 all versions prior to V2.80, which could cause a possible denial of service when sending an appropriately timed HTTP request to the controller.
- risk 0.38cvss 5.9epss 0.01
A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is…
- risk 0.38cvss 5.9epss 0.01
A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack.
- risk 0.38cvss 5.8epss 0.05
An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory traversal attack, an unauthorized person can view web server files.
- risk 0.38cvss 5.9epss 0.00
Unquoted Windows search path vulnerability in Schneider Electric Floating License Manager 1.0.0 through 1.4.0 allows local users to gain privileges via a Trojan horse application with a name composed of an initial substring of a path that contains a space character.
- risk 0.37cvss 5.7epss 0.00
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221…
- risk 0.37cvss 5.6epss 0.08
Systems with microprocessors utilizing speculative execution and branch prediction may allow unauthorized disclosure of information to an attacker with local user access via a speculative buffer overflow and side-channel analysis.
- risk 0.36cvss 5.5epss 0.01
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote control over the charging station when an authenticated user modifies configuration parameters on the web server.
- risk 0.36cvss 5.5epss 0.00
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause loss of confidentiality when replacing a project file on the local filesystem and after manual restart of the server.
- risk 0.36cvss 5.6epss 0.01
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow a user that knows the credentials to execute unprivileged shell commands on the appliance over SSH. …
- risk 0.36cvss 5.5epss 0.00
A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above)
- risk 0.36cvss 5.5epss 0.00
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior).
- risk 0.36cvss 5.5epss 0.01
A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA…
- risk 0.36cvss 5.5epss 0.01
A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could result in information disclosure when opening a malicious solution file provided by an attacker with SCADAPack Workbench. This could be exploited to pass data from local files to a…
- risk 0.36cvss 5.5epss 0.01
A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
- risk 0.36cvss 5.5epss 0.00
Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack…
- risk 0.36cvss 5.5epss 0.00
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack…
- risk 0.36cvss 5.5epss 0.01
A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 (all references, all versions), that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection…
- risk 0.36cvss 5.5epss 0.01
A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Transversal') vulnerability exists in SCADAPack 7x Remote Connect (V3.6.3.574 and prior) which allows an attacker to place content in any unprotected folder on the target system using a crafted .RCZ file.
- risk 0.36cvss 5.5epss 0.00
A CWE-312: Cleartext Storage of Sensitive Information vulnerability exists in Easergy Builder (Version 1.4.7.2 and older) which could allow an attacker to read user credentials.
- risk 0.36cvss 5.5epss 0.01
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability during zip file extraction exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD) which could cause unauthorized write access…
- risk 0.36cvss 5.5epss 0.00
An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmware V1.10.0.0) which could cause unauthorized access to SoMachine Basic resource files when logged on the system hosting…
- risk 0.36cvss 5.5epss 0.00
A Cryptographic Issue (CWE-310) vulnerability exists in IIoT Monitor 3.1.38 which could allow information disclosure.
- risk 0.36cvss 5.5epss 0.00
A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system accepts reboot in session from unauthenticated users, supporting a denial of service condition.
Page 14 of 18