Vendor CVEs
Schneider Electric
All CVEs
880 total · sorted by risk| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2023-27983 | Med | 0.42 | 6.5 | 0.00 | Mar 21, 2023 | A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow deletion of reports from the IGSS project report directory, this would lead to loss of data when an attacker abuses this functionality. Affected… | ||
| CVE-2023-27979 | Med | 0.42 | 6.5 | 0.00 | Mar 21, 2023 | A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could allow the renaming of files in the IGSS project report directory, this could lead to denial of service when an attacker sends specific crafted messages to the Data Server… | ||
| CVE-2023-27977 | Med | 0.42 | 6.5 | 0.00 | Mar 21, 2023 | A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP… | ||
| CVE-2022-32517 | Med | 0.42 | 6.5 | 0.00 | Jan 30, 2023 | A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause an adversary to trick the interface user/admin into interacting with the application in an unintended way when the product does not implement restrictions on the ability to… | ||
| CVE-2022-22731 | Med | 0.42 | 6.5 | 0.01 | Jan 30, 2023 | A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal… | ||
| CVE-2022-0223 | Med | 0.42 | 6.5 | 0.01 | Jan 30, 2023 | A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution.… | ||
| CVE-2022-30233 | Med | 0.42 | 6.5 | 0.01 | Jun 2, 2022 | A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior) | ||
| CVE-2022-22726 | Med | 0.42 | 6.5 | 0.01 | Feb 4, 2022 | A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior) | ||
| CVE-2021-22791 | Med | 0.42 | 6.5 | 0.01 | Sep 2, 2021 | A CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions),… | ||
| CVE-2021-22790 | Med | 0.42 | 6.5 | 0.01 | Sep 2, 2021 | A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions),… | ||
| CVE-2021-22789 | Med | 0.42 | 6.5 | 0.01 | Sep 2, 2021 | A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580… | ||
| CVE-2021-22773 | Med | 0.42 | 6.5 | 0.01 | Jul 21, 2021 | A CWE-620: Unverified Password Change vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that… | ||
| CVE-2021-22770 | Med | 0.42 | 6.5 | 0.01 | Jul 21, 2021 | A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitly authorized to have access to that information. | ||
| CVE-2021-22728 | Med | 0.42 | 6.5 | 0.01 | Jul 21, 2021 | A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could… | ||
| CVE-2021-22740 | Med | 0.42 | 6.5 | 0.01 | May 26, 2021 | Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded. | ||
| CVE-2020-28218 | Med | 0.42 | 6.5 | 0.01 | Dec 11, 2020 | A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to trick a user into initiating an unintended action. | ||
| CVE-2020-7573 | Med | 0.42 | 6.5 | 0.01 | Nov 19, 2020 | A CWE-284 Improper Access Control vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker being able to access a restricted web resources due to improper access control. | ||
| CVE-2020-7499 | Med | 0.42 | 6.5 | 0.01 | Jun 16, 2020 | A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes. | ||
| CVE-2020-7492 | Med | 0.42 | 6.5 | 0.01 | Jun 16, 2020 | A CWE-521: Weak Password Requirements vulnerability exists in the GP-Pro EX V1.00 to V4.09.100 which could cause the discovery of the password when the user is entering the password because it is not masqueraded. | ||
| CVE-2019-6846 | Med | 0.42 | 6.5 | 0.01 | Oct 29, 2019 | A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol. | ||
| CVE-2019-6838 | Med | 0.42 | 6.5 | 0.01 | Sep 17, 2019 | A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a… | ||
| CVE-2019-6833 | Med | 0.42 | 6.5 | 0.01 | Sep 17, 2019 | A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high… | ||
| CVE-2019-6821 | Med | 0.42 | 6.5 | 0.02 | May 22, 2019 | CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum. | ||
| CVE-2018-7851 | Med | 0.42 | 6.5 | 0.01 | May 22, 2019 | CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus… | ||
| CVE-2018-7816 | Med | 0.42 | 6.5 | 0.01 | May 22, 2019 | A Permissions, Privileges, and Access Control vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to delete an arbitrary file. | ||
| CVE-2018-7788 | Med | 0.42 | 6.5 | 0.01 | May 22, 2019 | A CWE-255 Credentials Management vulnerability exists in Modicon Quantum with firmware versions prior to V2.40. which could cause a Denial Of Service when using a Telnet connection. | ||
| CVE-2018-7770 | Med | 0.42 | 6.5 | 0.01 | Jul 3, 2018 | The vulnerability exists within processing of sendmail.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The applet allows callers to select arbitrary files to send to an arbitrary email address. | ||
| CVE-2018-7758 | Med | 0.42 | 6.5 | 0.01 | Apr 18, 2018 | A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy Ethernet Board, and MiCOM Px4x Rejuvenated could lose network communication in case of TCP/IP open requests on port 20000… | ||
| CVE-2017-7971 | Med | 0.42 | 6.5 | 0.01 | Sep 26, 2017 | A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the use of outdated cipher suites and improper verification of peer SSL Certificate. | ||
| CVE-2017-7970 | Med | 0.42 | 6.5 | 0.01 | Sep 26, 2017 | A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure… | ||
| CVE-2017-6030 | Med | 0.42 | 6.5 | 0.02 | Jun 30, 2017 | A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version… | ||
| CVE-2016-2292 | Med | 0.42 | 6.5 | 0.02 | Apr 6, 2016 | Stack-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors. | ||
| CVE-2016-2291 | Med | 0.42 | 6.5 | 0.02 | Apr 6, 2016 | Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allow remote attackers to execute arbitrary code or cause a denial of service (out-of-bounds read) via unspecified vectors. | ||
| CVE-2022-34755 | Med | 0.41 | 6.3 | 0.00 | Apr 18, 2023 | A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker with a local privileged account to place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code during the installation… | ||
| CVE-2018-7796 | Med | 0.41 | 6.3 | 0.01 | Dec 24, 2018 | A Buffer Error vulnerability exists in PowerSuite 2, all released versions (VW3A8104 & Patches), which could cause an overflow in the memcpy function, leading to corruption of data and program instability. | ||
| CVE-2026-2399 | Med | 0.40 | 6.1 | 0.00 | Apr 14, 2026 | CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload. | ||
| CVE-2024-5559 | Med | 0.40 | 6.1 | 0.00 | Jun 12, 2024 | CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists that could cause denial of service, device reboot, or an attacker gaining full control of the relay when a specially crafted reset token is entered into the front panel of the device. | ||
| CVE-2023-5987 | Med | 0.40 | 6.1 | 0.00 | Nov 15, 2023 | A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page… | ||
| CVE-2023-25553 | Med | 0.40 | 6.1 | 0.00 | Apr 18, 2023 | A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and… | ||
| CVE-2023-25551 | Med | 0.40 | 6.1 | 0.00 | Apr 18, 2023 | A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and… | ||
| CVE-2022-22812 | Med | 0.40 | 6.1 | 0.01 | Feb 9, 2022 | A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a web session compromise when an attacker injects and then executes arbitrary malicious JavaScript code inside the target browser. Affected… | ||
| CVE-2021-22822 | Med | 0.40 | 6.1 | 0.01 | Jan 28, 2022 | A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are… | ||
| CVE-2021-22814 | Med | 0.40 | 6.1 | 0.01 | Jan 28, 2022 | A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2… | ||
| CVE-2021-22813 | Med | 0.40 | 6.1 | 0.01 | Jan 28, 2022 | A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file.… | ||
| CVE-2021-22812 | Med | 0.40 | 6.1 | 0.01 | Jan 28, 2022 | A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase… | ||
| CVE-2021-22811 | Med | 0.40 | 6.1 | 0.01 | Jan 28, 2022 | A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase… | ||
| CVE-2021-22810 | Med | 0.40 | 6.1 | 0.01 | Jan 28, 2022 | A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file.… | ||
| CVE-2021-22723 | Med | 0.40 | 6.1 | 0.01 | Jul 21, 2021 | A CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting) through Cross-Site Request Forgery (CSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions… | ||
| CVE-2021-22706 | Med | 0.40 | 6.1 | 0.01 | Jul 21, 2021 | A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart… | ||
| CVE-2020-28210 | Med | 0.40 | 6.1 | 0.01 | Nov 19, 2020 | A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser. |
- risk 0.42cvss 6.5epss 0.00
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow deletion of reports from the IGSS project report directory, this would lead to loss of data when an attacker abuses this functionality. Affected…
- risk 0.42cvss 6.5epss 0.00
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could allow the renaming of files in the IGSS project report directory, this could lead to denial of service when an attacker sends specific crafted messages to the Data Server…
- risk 0.42cvss 6.5epss 0.00
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP…
- risk 0.42cvss 6.5epss 0.00
A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause an adversary to trick the interface user/admin into interacting with the application in an unintended way when the product does not implement restrictions on the ability to…
- risk 0.42cvss 6.5epss 0.01
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in a function that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause path traversal…
- risk 0.42cvss 6.5epss 0.01
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could allow an attacker to create or overwrite critical files that are used to execute code, such as programs or libraries and cause unauthenticated code execution.…
- risk 0.42cvss 6.5epss 0.01
A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
- risk 0.42cvss 6.5epss 0.01
A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)
- risk 0.42cvss 6.5epss 0.01
A CWE-787: Out-of-bounds Write vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions),…
- risk 0.42cvss 6.5epss 0.01
A CWE-125: Out-of-bounds Read vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU (part numbers BMEP* and BMEH*, all versions),…
- risk 0.42cvss 6.5epss 0.01
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580…
- risk 0.42cvss 6.5epss 0.01
A CWE-620: Unverified Password Change vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that…
- risk 0.42cvss 6.5epss 0.01
A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitly authorized to have access to that information.
- risk 0.42cvss 6.5epss 0.01
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could…
- risk 0.42cvss 6.5epss 0.01
Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded.
- risk 0.42cvss 6.5epss 0.01
A CWE-1021: Improper Restriction of Rendered UI Layers or Frames vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to trick a user into initiating an unintended action.
- risk 0.42cvss 6.5epss 0.01
A CWE-284 Improper Access Control vulnerability exists in EcoStruxure Building Operation WebReports V1.9 - V3.1 that could cause a remote attacker being able to access a restricted web resources due to improper access control.
- risk 0.42cvss 6.5epss 0.01
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause unauthorized access when a low privileged user makes unauthorized changes.
- risk 0.42cvss 6.5epss 0.01
A CWE-521: Weak Password Requirements vulnerability exists in the GP-Pro EX V1.00 to V4.09.100 which could cause the discovery of the password when the user is entering the password because it is not masqueraded.
- risk 0.42cvss 6.5epss 0.01
A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol.
- risk 0.42cvss 6.5epss 0.01
A CWE-863: Incorrect Authorization vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow a…
- risk 0.42cvss 6.5epss 0.01
A CWE-754 – Improper Check for Unusual or Exceptional Conditions vulnerability exists in Magelis HMI Panels (all versions of - HMIGTO, HMISTO, XBTGH, HMIGTU, HMIGTUX, HMISCU, HMISTU, XBTGT, XBTGT, HMIGXO, HMIGXU), which could cause a temporary freeze of the HMI when a high…
- risk 0.42cvss 6.5epss 0.02
CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum.
- risk 0.42cvss 6.5epss 0.01
CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus…
- risk 0.42cvss 6.5epss 0.01
A Permissions, Privileges, and Access Control vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker to delete an arbitrary file.
- risk 0.42cvss 6.5epss 0.01
A CWE-255 Credentials Management vulnerability exists in Modicon Quantum with firmware versions prior to V2.40. which could cause a Denial Of Service when using a Telnet connection.
- risk 0.42cvss 6.5epss 0.01
The vulnerability exists within processing of sendmail.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The applet allows callers to select arbitrary files to send to an arbitrary email address.
- risk 0.42cvss 6.5epss 0.01
A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy Ethernet Board, and MiCOM Px4x Rejuvenated could lose network communication in case of TCP/IP open requests on port 20000…
- risk 0.42cvss 6.5epss 0.01
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the use of outdated cipher suites and improper verification of peer SSL Certificate.
- risk 0.42cvss 6.5epss 0.01
A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure…
- risk 0.42cvss 6.5epss 0.02
A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version…
- risk 0.42cvss 6.5epss 0.02
Stack-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors.
- risk 0.42cvss 6.5epss 0.02
Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allow remote attackers to execute arbitrary code or cause a denial of service (out-of-bounds read) via unspecified vectors.
- risk 0.41cvss 6.3epss 0.00
A CWE-427 - Uncontrolled Search Path Element vulnerability exists that could allow an attacker with a local privileged account to place a specially crafted file on the target machine, which may give the attacker the ability to execute arbitrary code during the installation…
- risk 0.41cvss 6.3epss 0.01
A Buffer Error vulnerability exists in PowerSuite 2, all released versions (VW3A8104 & Patches), which could cause an overflow in the memcpy function, leading to corruption of data and program instability.
- risk 0.40cvss 6.1epss 0.00
CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload.
- risk 0.40cvss 6.1epss 0.00
CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists that could cause denial of service, device reboot, or an attacker gaining full control of the relay when a specially crafted reset token is entered into the front panel of the device.
- risk 0.40cvss 6.1epss 0.00
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page…
- risk 0.40cvss 6.1epss 0.00
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE endpoint through the logging capabilities of the webserver. Affected products: StruxureWare Data Center Expert (V7.9.2 and…
- risk 0.40cvss 6.1epss 0.00
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists on a DCE file upload endpoint when tampering with parameters over HTTP. Affected products: StruxureWare Data Center Expert (V7.9.2 and…
- risk 0.40cvss 6.1epss 0.01
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a web session compromise when an attacker injects and then executes arbitrary malicious JavaScript code inside the target browser. Affected…
- risk 0.40cvss 6.1epss 0.01
A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are…
- risk 0.40cvss 6.1epss 0.01
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2…
- risk 0.40cvss 6.1epss 0.01
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file.…
- risk 0.40cvss 6.1epss 0.01
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase…
- risk 0.40cvss 6.1epss 0.01
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase…
- risk 0.40cvss 6.1epss 0.01
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file.…
- risk 0.40cvss 6.1epss 0.01
A CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting) through Cross-Site Request Forgery (CSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions…
- risk 0.40cvss 6.1epss 0.01
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart…
- risk 0.40cvss 6.1epss 0.01
A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability exists in EcoStruxure Building Operation WebStation V2.0 - V3.1 that could cause an attacker to inject HTML and JavaScript code into the user's browser.
Page 13 of 18