VYPR

Control Expert

by EcoStruxure

CVEs (11)

  • CVE-2020-28212CriNov 19, 2020
    risk 0.64cvss 9.8epss 0.03

    A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when a brute force attack is done over Modbus.

  • CVE-2020-7475CriMar 23, 2020
    risk 0.64cvss 9.8epss 0.02

    A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to…

  • CVE-2023-27976HigApr 18, 2023
    risk 0.57cvss 8.8epss 0.01

    A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Control Expert (V15.1 and above)

  • CVE-2020-7560HigDec 11, 2020
    risk 0.56cvss 8.6epss 0.01

    A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious…

  • CVE-2020-28211HigNov 19, 2020
    risk 0.51cvss 7.8epss 0.00

    A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.

  • CVE-2020-7559HigNov 19, 2020
    risk 0.49cvss 7.5epss 0.02

    A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software…

  • CVE-2019-6855HigJan 6, 2020
    risk 0.48cvss 7.3epss 0.01

    Incorrect Authorization vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20) , and Modicon M580 (all versions prior to V3.10), which could cause a bypass of the…

  • CVE-2021-22778HigJul 14, 2021
    risk 0.46cvss 7.1epss 0.00

    Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack…

  • CVE-2023-1548MedApr 18, 2023
    risk 0.36cvss 5.5epss 0.00

    A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above)

  • CVE-2021-22782MedJul 14, 2021
    risk 0.36cvss 5.5epss 0.00

    Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack…

  • CVE-2021-22781MedJul 14, 2021
    risk 0.36cvss 5.5epss 0.00

    Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack…