VYPR

Vendor CVEs

Siemens Foundation

All CVEs

2,020 total · sorted by risk
  • CVE-2021-22946HigSep 29, 2021
    risk 0.42cvss 7.5epss 0.04

    A user can tell curl >= 7.20.0 and <= 7.78.0 to require a successful upgrade to TLS when speaking to an IMAP, POP3 or FTP server (`--ssl-reqd` on the command line or`CURLOPT_USE_SSL` set to `CURLUSESSL_CONTROL` or `CURLUSESSL_ALL` withlibcurl). This requirement could be bypassed…

  • CVE-2020-26145MedMay 11, 2021
    risk 0.42cvss 6.5epss 0.04

    An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept second (or subsequent) broadcast fragments even when sent in plaintext and process them as full unfragmented frames. An adversary can abuse this to inject…

  • CVE-2020-26144MedMay 11, 2021
    risk 0.42cvss 6.5epss 0.05

    An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext A-MSDU frames as long as the first 8 bytes correspond to a valid RFC1042 (i.e., LLC/SNAP) header for EAPOL. An adversary can abuse this to inject…

  • CVE-2020-26143MedMay 11, 2021
    risk 0.42cvss 6.5epss 0.04

    An issue was discovered in the ALFA Windows 10 driver 1030.36.604 for AWUS036ACH. The WEP, WPA, WPA2, and WPA3 implementations accept fragmented plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network…

  • CVE-2020-26141MedMay 11, 2021
    risk 0.42cvss 6.5epss 0.03

    An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The Wi-Fi implementation does not verify the Message Integrity Check (authenticity) of fragmented TKIP frames. An adversary can abuse this to inject and possibly decrypt packets in WPA or WPA2…

  • CVE-2020-26140MedMay 11, 2021
    risk 0.42cvss 6.5epss 0.03

    An issue was discovered in the ALFA Windows 10 driver 6.1316.1209 for AWUS036H. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext frames in a protected Wi-Fi network. An adversary can abuse this to inject arbitrary data frames independent of the network configuration.

  • CVE-2020-8285HigDec 14, 2020
    risk 0.42cvss 7.5epss 0.10

    curl 7.21.0 to and including 7.73.0 is vulnerable to uncontrolled recursion due to a stack overflow issue in FTP wildcard match parsing.

  • CVE-2020-15791MedSep 9, 2020
    risk 0.42cvss 6.5epss 0.01

    A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The…

  • CVE-2019-6576MedMay 14, 2019
    risk 0.42cvss 6.5epss 0.02

    A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions <…

  • CVE-2018-4855MedJul 3, 2018
    risk 0.42cvss 6.5epss 0.01

    A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). Unencrypted storage of passwords in the client configuration files and during network transmission could allow an attacker in a privileged position to obtain access passwords.

  • CVE-2018-4843MedMar 20, 2018
    risk 0.42cvss 6.5epss 0.01

    A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions <…

  • CVE-2017-9945MedAug 30, 2017
    risk 0.42cvss 6.5epss 0.01

    In the Siemens 7KM PAC Switched Ethernet PROFINET expansion module (All versions < V2.1.3), a Denial-of-Service condition could be induced by a specially crafted PROFINET DCP packet sent as a local Ethernet (Layer 2) broadcast. The affected component requires a manual restart…

  • CVE-2017-6872MedAug 8, 2017
    risk 0.42cvss 6.5epss 0.01

    A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to access or alter historical measurement data stored on the device.

  • CVE-2017-6866MedAug 7, 2017
    risk 0.42cvss 6.5epss 0.01

    A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceeding his configured permission level.

  • CVE-2015-5219HigJul 21, 2017
    risk 0.42cvss 7.5epss 0.06

    The ULOGTOD function in ntp.d in SNTP before 4.2.7p366 does not properly perform type conversions from a precision value to a double, which allows remote attackers to cause a denial of service (infinite loop) via a crafted NTP packet.

  • CVE-2017-6865MedMay 11, 2017
    risk 0.42cvss 6.5epss 0.00

    A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC…

  • CVE-2017-2681MedMay 11, 2017
    risk 0.42cvss 6.5epss 0.01

    Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.

  • CVE-2017-2680MedMay 11, 2017
    risk 0.42cvss 6.5epss 0.01

    Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.

  • CVE-2017-2686MedMar 29, 2017
    risk 0.42cvss 6.5epss 0.01

    Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability that could allow an authenticated user to read arbitrary files through the web interface at port 10000/TCP and access sensitive information.

  • CVE-2016-7165MedNov 15, 2016
    risk 0.42cvss 6.4epss 0.00

    A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS…

  • CVE-2016-8564MedOct 13, 2016
    risk 0.42cvss 6.5epss 0.01

    SQL injection vulnerability in Siemens Automation License Manager (ALM) before 5.3 SP3 Update 1 allows remote attackers to execute arbitrary SQL commands via crafted traffic to TCP port 4410.

  • CVE-2016-2846MedMar 16, 2016
    risk 0.42cvss 6.5epss 0.02

    Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a "user program block" protection mechanism via unspecified vectors.

  • CVE-2026-35535HigApr 3, 2026
    risk 0.41cvss 7.4epss 0.00

    In Sudo through 1.9.17p2 before 3e474c2, a failure of a setuid, setgid, or setgroups call, during a privilege drop before running the mailer, is not a fatal error and can lead to privilege escalation.

  • CVE-2023-32737MedJul 9, 2024
    risk 0.41cvss 6.3epss 0.00

    A vulnerability has been identified in SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute…

  • CVE-2024-33497MedMay 14, 2024
    risk 0.41cvss 6.3epss 0.00

    A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating…

  • CVE-2024-33496MedMay 14, 2024
    risk 0.41cvss 6.3epss 0.00

    A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating…

  • CVE-2024-30208MedMay 14, 2024
    risk 0.41cvss 6.3epss 0.00

    A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating…

  • CVE-2021-3712HigAug 24, 2021
    risk 0.41cvss 7.4epss 0.50

    ASN.1 strings are represented internally within OpenSSL as an ASN1_STRING structure which contains a buffer holding the string data and a field holding the buffer length. This contrasts with normal C strings which are repesented as a buffer for the string data which is…

  • CVE-2025-40808MedJun 9, 2026
    risk 0.40cvss 6.1epss 0.00

    A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All…

  • CVE-2025-40753MedAug 12, 2025
    risk 0.40cvss 6.2epss 0.00

    A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER…

  • CVE-2025-40752MedAug 12, 2025
    risk 0.40cvss 6.2epss 0.00

    A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER…

  • CVE-2024-35295MedJun 11, 2025
    risk 0.40cvss 6.1epss 0.00

    A vulnerability has been identified in Perfect Harmony GH180 (All versions >= V8.0 < V8.3.3 with NXGPro+ controller manufactured between April 2020 to April 2025). The maintenance connection of affected devices fails to protect access to the device's control unit configuration.…

  • CVE-2024-30190MedApr 9, 2024
    risk 0.40cvss 6.1epss 0.00

    A vulnerability has been identified in SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0), SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0), SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0), SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0), SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0), SCALANCE W1788-2IA…

  • CVE-2024-30189MedApr 9, 2024
    risk 0.40cvss 6.1epss 0.00

    A vulnerability has been identified in SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) (All versions), SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0) (All versions), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0) (All versions), SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0) (All versions), SCALANCE…

  • CVE-2023-50821MedApr 9, 2024
    risk 0.40cvss 6.2epss 0.00

    A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC04), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All…

  • CVE-2018-11450MedJul 9, 2018
    risk 0.40cvss 6.1epss 0.01

    A reflected Cross-Site-Scripting (XSS) vulnerability has been identified in Siemens PLM Software TEAMCENTER (V9.1.2.5). If a user visits the login portal through the URL crafted by the attacker, the attacker can insert html/javascript and thus alter/rewrite the login portal…

  • CVE-2018-4848MedJun 14, 2018
    risk 0.40cvss 6.1epss 0.01

    A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300…

  • CVE-2017-12738MedNov 15, 2017
    risk 0.40cvss 6.1epss 0.01

    An issue was discovered on Siemens SICAM RTUs SM-2556 COM Modules with the firmware variants ENOS00, ERAC00, ETA2, ETLS00, MODi00, and DNPi00. The integrated web server (port 80/tcp) of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are…

  • CVE-2017-2687MedMar 29, 2017
    risk 0.40cvss 6.1epss 0.01

    Siemens RUGGEDCOM ROX I (all versions) contain a vulnerability in the integrated web server at port 10000/TCP which is prone to reflected Cross-Site Scripting attacks if an unsuspecting user is induced to click on a malicious link.

  • CVE-2016-6204MedJul 22, 2016
    risk 0.40cvss 6.1epss 0.02

    Cross-site scripting (XSS) vulnerability in the integrated web server in Siemens SINEMA Remote Connect Server before 1.2 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.

  • CVE-2016-1488MedJan 30, 2016
    risk 0.40cvss 6.1epss 0.01

    Cross-site scripting (XSS) vulnerability in the login form in the integrated web server on Siemens OZW OZW672 devices before 6.00 and OZW772 devices before 6.00 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.

  • CVE-2015-7977MedJan 30, 2017
    risk 0.39cvss 5.9epss 0.06

    ntpd in NTP before 4.2.8p6 and 4.3.x before 4.3.90 allows remote attackers to cause a denial of service (NULL pointer dereference) via a ntpdc reslist command.

  • CVE-2016-4955MedJul 5, 2016
    risk 0.39cvss 5.9epss 0.09

    ntpd in NTP 4.x before 4.2.8p8, when autokey is enabled, allows remote attackers to cause a denial of service (peer-variable clearing and association outage) by sending (1) a spoofed crypto-NAK packet or (2) a packet with an incorrect MAC value at a certain time.

  • CVE-2025-40903MedMay 19, 2026
    risk 0.38cvss 5.9epss 0.00

    A Stored HTML Injection vulnerability was discovered in the Schedule Restore Archive functionality due to improper validation of an input parameter. An authenticated user with administrative privileges can define a malicious restore schedule containing HTML tags. When a victim…

  • CVE-2025-40902MedMay 19, 2026
    risk 0.38cvss 5.9epss 0.00

    A Stored HTML Injection vulnerability was discovered in the Users functionality due to improper validation of an input parameter. An authenticated user with administrative privileges can create a malicious user whose username contains HTML tags. When a victim attempts to delete…

  • CVE-2025-40901MedMay 19, 2026
    risk 0.38cvss 5.9epss 0.00

    A Stored HTML Injection vulnerability was discovered in the Credentials Manager functionality due to improper validation of an input parameter. An authenticated user with administrative privileges can define a malicious identity containing HTML tags. When a victim attempts to…

  • CVE-2025-24009MedMay 13, 2025
    risk 0.38cvss 5.9epss 0.00

    A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not require authentication to access critical resources. An attacker with network access could retrieve sensitive…

  • CVE-2024-54090MedFeb 11, 2025
    risk 0.38cvss 5.9epss 0.00

    A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain an out-of-bounds read in the memory dump function. This could allow an attacker…

  • CVE-2023-30756MedSep 10, 2024
    risk 0.38cvss 5.9epss 0.00

    A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl.…

  • CVE-2023-28827MedSep 10, 2024
    risk 0.38cvss 5.9epss 0.00

    A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl.…

Page 6 of 41