2,020 total · sorted by risk| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2018-4849 | Hig | 0.48 | 7.4 | 0.01 | May 3, 2018 | A vulnerability has been identified in Siveillance VMS Video for Android (All versions < V12.1a (2018 R1)), Siveillance VMS Video for iOS (All versions < V12.1a (2018 R1)). Improper certificate validation could allow an attacker in a privileged network position to read data from… | ||
| CVE-2017-12735 | Hig | 0.48 | 7.4 | 0.01 | Aug 30, 2017 | A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. | ||
| CVE-2017-9941 | Hig | 0.48 | 7.4 | 0.01 | Aug 8, 2017 | A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication. | ||
| CVE-2017-6873 | Hig | 0.48 | 7.4 | 0.01 | Aug 8, 2017 | A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp. | ||
| CVE-2017-6870 | Hig | 0.48 | 7.4 | 0.01 | Aug 8, 2017 | A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack. | ||
| CVE-2015-7855 | Med | 0.48 | 6.5 | 0.31 | Aug 7, 2017 | The decodenetnum function in ntpd in NTP 4.2.x before 4.2.8p4, and 4.3.x before 4.3.77 allows remote attackers to cause a denial of service (assertion failure) via a 6 or mode 7 packet containing a long data value. | ||
| CVE-2017-2685 | Hig | 0.48 | 7.4 | 0.01 | Mar 1, 2017 | Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a… | ||
| CVE-2016-9156 | Hig | 0.48 | 7.3 | 0.02 | Dec 5, 2016 | A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to upload, download, or delete files in certain parts of the file system by sending specially crafted packets to port 19235/TCP. | ||
| CVE-2026-33862 | Hig | 0.47 | 7.3 | 0.00 | May 12, 2026 | A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009), Teamcenter V2506 (All versions < V2506.0005), Teamcenter V2512 (All versions). The affected… | ||
| CVE-2026-24032 | Hig | 0.47 | 7.3 | 0.00 | Apr 14, 2026 | A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP3 with UMC). The affected application contains an authentication weakness due to insufficient validation of user identity in the UMC component. This could allow an unauthenticated remote attacker to bypass… | ||
| CVE-2025-40815 | Hig | 0.47 | 7.2 | 0.00 | Nov 11, 2025 | A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2)… | ||
| CVE-2025-24499 | Hig | 0.47 | 7.2 | 0.01 | Feb 11, 2025 | A vulnerability has been identified in SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)… | ||
| CVE-2024-52051 | Hig | 0.47 | 7.3 | 0.00 | Dec 10, 2024 | A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC… | ||
| CVE-2023-32736 | Hig | 0.47 | 7.3 | 0.00 | Nov 12, 2024 | A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC… | ||
| CVE-2024-31485 | Hig | 0.47 | 7.2 | 0.02 | May 14, 2024 | A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.30), SICORE Base system (All versions < V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could… | ||
| CVE-2018-4859 | Hig | 0.47 | 7.2 | 0.04 | Jun 26, 2018 | A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web… | ||
| CVE-2017-5712 | Hig | 0.47 | 7.2 | 0.04 | Nov 21, 2017 | Buffer overflow in Active Management Technology (AMT) in Intel Manageability Engine Firmware 8.x/9.x/10.x/11.0/11.5/11.6/11.7/11.10/11.20 allows attacker with remote Admin access to the system to execute arbitrary code with AMT execution privilege. | ||
| CVE-2026-24349 | Hig | 0.46 | 7.1 | 0.00 | Jun 9, 2026 | A vulnerability has been identified in SIMATIC WinCC Unified PC Runtime V16 (All versions), SIMATIC WinCC Unified PC Runtime V17 (All versions), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions), SIMATIC WinCC Unified PC… | ||
| CVE-2026-33892 | Hig | 0.46 | 7.1 | 0.00 | Apr 14, 2026 | A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do… | ||
| CVE-2025-38502 | Hig | 0.46 | 7.1 | 0.00 | Aug 16, 2025 | In the Linux kernel, the following vulnerability has been resolved: bpf: Fix oob access in cgroup local storage Lonial reported that an out-of-bounds access in cgroup local storage can be crafted via tail calls. Given two programs each utilizing a cgroup local storage with a… | ||
| CVE-2023-52236 | Hig | 0.46 | 7.0 | 0.00 | Jul 8, 2025 | A vulnerability has been identified in RUGGEDCOM i800 (All versions), RUGGEDCOM i801 (All versions), RUGGEDCOM i802 (All versions), RUGGEDCOM i803 (All versions), RUGGEDCOM M2100 (All versions), RUGGEDCOM M2200 (All versions), RUGGEDCOM M969 (All versions), RUGGEDCOM RMC30 (All… | ||
| CVE-2025-23403 | Hig | 0.46 | 7.0 | 0.00 | Feb 11, 2025 | A vulnerability has been identified in SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions). The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into… | ||
| CVE-2024-47100 | Hig | 0.46 | 7.1 | 0.00 | Jan 14, 2025 | A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0), SIMATIC… | ||
| CVE-2025-40948 | Med | 0.44 | 6.8 | 0.00 | May 12, 2026 | A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versions < V2.17.1), RUGGEDCOM ROX RX1400 (All versions < V2.17.1), RUGGEDCOM ROX RX1500 (All versions < V2.17.1), RUGGEDCOM ROX RX1501 (All versions < V2.17.1),… | ||
| CVE-2025-30000 | Med | 0.44 | 6.7 | 0.00 | Apr 8, 2025 | A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3). The affected application does not properly restrict permissions of the users. This could allow a lowly-privileged attacker to escalate their privileges. | ||
| CVE-2025-29999 | Med | 0.44 | 6.7 | 0.00 | Apr 8, 2025 | A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3). The affected application searches for executable files in the application folder without proper validation. This could allow an attacker to execute arbitrary code with administrative… | ||
| CVE-2024-53648 | Med | 0.44 | 6.8 | 0.00 | Feb 11, 2025 | A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.90), SIPROTEC 5… | ||
| CVE-2022-36325 | Med | 0.44 | 6.8 | 0.01 | Aug 10, 2022 | Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS. | ||
| CVE-2018-3639 | Med | 0.44 | 5.5 | 0.61 | May 22, 2018 | Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis,… | ||
| CVE-2018-4844 | Med | 0.44 | 6.7 | 0.00 | Mar 20, 2018 | A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to… | ||
| CVE-2017-13084 | Med | 0.44 | 6.8 | 0.02 | Oct 17, 2017 | Wi-Fi Protected Access (WPA and WPA2) allows reinstallation of the Station-To-Station-Link (STSL) Transient Key (STK) during the PeerKey handshake, allowing an attacker within radio range to replay, decrypt, or spoof frames. | ||
| CVE-2016-5848 | Med | 0.44 | 6.7 | 0.00 | Jul 4, 2016 | Siemens SICAM PAS before 8.07 does not properly restrict password data in the database, which makes it easier for local users to calculate passwords by leveraging unspecified database privileges. | ||
| CVE-2024-38278 | Med | 0.43 | 6.6 | 0.00 | Jul 9, 2024 | A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.9.0), RUGGEDCOM RMC8388NC V5.X (All versions < V5.9.0), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416Pv2 V5.X (All versions <… | ||
| CVE-2015-7973 | Med | 0.43 | 6.5 | 0.03 | Jan 30, 2017 | NTP before 4.2.8p6 and 4.3.x before 4.3.90, when configured in broadcast mode, allows man-in-the-middle attackers to conduct replay attacks by sniffing the network. | ||
| CVE-2016-8561 | Med | 0.43 | 6.6 | 0.02 | Nov 18, 2016 | A vulnerability has been identified in SIMATIC CP 1543-1 (All versions < V2.0.28), SIPLUS NET CP 1543-1 (All versions < V2.0.28). Users with elevated privileges to TIA-Portal and project data on the engineering station could possibly get privileged access on affected devices. | ||
| CVE-2025-40904 | Med | 0.42 | 6.5 | 0.00 | May 19, 2026 | A Stored HTML Injection vulnerability was discovered in the Smart Polling functionality due to improper validation of an input parameter. An authenticated user with limited privileges can push malicious remote strategies containing HTML tags through the sync. When a victim views… | ||
| CVE-2026-27663 | Med | 0.42 | 6.5 | 0.00 | Mar 26, 2026 | A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.10), RTUM85 RTU Base (All versions < V26.10). The affected application contains denial-of-service (DoS) vulnerability. The remote operation mode is susceptible to a resource… | ||
| CVE-2025-40817 | Med | 0.42 | 6.5 | 0.00 | Nov 11, 2025 | A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2)… | ||
| CVE-2025-40567 | Med | 0.42 | 6.5 | 0.00 | Jun 10, 2025 | A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2),… | ||
| CVE-2025-40556 | Med | 0.42 | 6.5 | 0.00 | May 13, 2025 | A vulnerability has been identified in BACnet ATEC 550-440 (All versions), BACnet ATEC 550-441 (All versions), BACnet ATEC 550-445 (All versions), BACnet ATEC 550-446 (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an… | ||
| CVE-2025-24510 | Med | 0.42 | 6.5 | 0.00 | May 13, 2025 | A vulnerability has been identified in MS/TP Point Pickup Module (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a… | ||
| CVE-2025-24008 | Med | 0.42 | 6.5 | 0.00 | May 13, 2025 | A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not encrypt data in transit. An attacker with network access could eavesdrop the connection and retrieve sensitive… | ||
| CVE-2025-24812 | Med | 0.42 | 6.5 | 0.01 | Feb 11, 2025 | A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0) (All versions < V4.7),… | ||
| CVE-2024-53649 | Med | 0.42 | 6.5 | 0.01 | Jan 14, 2025 | A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85… | ||
| CVE-2024-39601 | Med | 0.42 | 6.5 | 0.01 | Jul 22, 2024 | A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.40), SICORE Base system (All versions < V1.4.0). Affected devices allow a remote authenticated user or an unauthenticated user with physical access to downgrade the firmware of the… | ||
| CVE-2023-32735 | Med | 0.42 | 6.5 | 0.00 | Jul 9, 2024 | A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17… | ||
| CVE-2024-33647 | Med | 0.42 | 6.5 | 0.00 | May 14, 2024 | A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The Apache Lucene based query engine in the affected application lacks proper access controls. This could allow an authenticated user to query items beyond the user's allowed projects. | ||
| CVE-2024-33495 | Med | 0.42 | 6.5 | 0.01 | May 14, 2024 | A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating… | ||
| CVE-2024-33494 | Med | 0.42 | 6.5 | 0.00 | May 14, 2024 | A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating… | ||
| CVE-2023-46280 | Med | 0.42 | 6.5 | 0.00 | May 14, 2024 | A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17… |
- risk 0.48cvss 7.4epss 0.01
A vulnerability has been identified in Siveillance VMS Video for Android (All versions < V12.1a (2018 R1)), Siveillance VMS Video for iOS (All versions < V12.1a (2018 R1)). Improper certificate validation could allow an attacker in a privileged network position to read data from…
- risk 0.48cvss 7.4epss 0.01
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic.
- risk 0.48cvss 7.4epss 0.01
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.
- risk 0.48cvss 7.4epss 0.01
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp.
- risk 0.48cvss 7.4epss 0.01
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack.
- risk 0.48cvss 6.5epss 0.31
The decodenetnum function in ntpd in NTP 4.2.x before 4.2.8p4, and 4.3.x before 4.3.77 allows remote attackers to cause a denial of service (assertion failure) via a 6 or mode 7 packet containing a long data value.
- risk 0.48cvss 7.4epss 0.01
Siemens SINUMERIK Integrate Operate Clients between 2.0.3.00.016 (including) and 2.0.6 (excluding) and between 3.0.4.00.032 (including) and 3.0.6 (excluding) contain a vulnerability that could allow an attacker to read and manipulate data in TLS sessions while performing a…
- risk 0.48cvss 7.3epss 0.02
A vulnerability in Siemens SICAM PAS (all versions before V8.09) could allow a remote attacker to upload, download, or delete files in certain parts of the file system by sending specially crafted packets to port 19235/TCP.
- risk 0.47cvss 7.3epss 0.00
A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009), Teamcenter V2506 (All versions < V2506.0005), Teamcenter V2512 (All versions). The affected…
- risk 0.47cvss 7.3epss 0.00
A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP3 with UMC). The affected application contains an authentication weakness due to insufficient validation of user identity in the UMC component. This could allow an unauthenticated remote attacker to bypass…
- risk 0.47cvss 7.2epss 0.00
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2)…
- risk 0.47cvss 7.2epss 0.01
A vulnerability has been identified in SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0)…
- risk 0.47cvss 7.3epss 0.00
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC…
- risk 0.47cvss 7.3epss 0.00
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC…
- risk 0.47cvss 7.2epss 0.02
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.30), SICORE Base system (All versions < V1.3.0). The web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could…
- risk 0.47cvss 7.2epss 0.04
A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web…
- risk 0.47cvss 7.2epss 0.04
Buffer overflow in Active Management Technology (AMT) in Intel Manageability Engine Firmware 8.x/9.x/10.x/11.0/11.5/11.6/11.7/11.10/11.20 allows attacker with remote Admin access to the system to execute arbitrary code with AMT execution privilege.
- risk 0.46cvss 7.1epss 0.00
A vulnerability has been identified in SIMATIC WinCC Unified PC Runtime V16 (All versions), SIMATIC WinCC Unified PC Runtime V17 (All versions), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions), SIMATIC WinCC Unified PC…
- risk 0.46cvss 7.1epss 0.00
A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do…
- risk 0.46cvss 7.1epss 0.00
In the Linux kernel, the following vulnerability has been resolved: bpf: Fix oob access in cgroup local storage Lonial reported that an out-of-bounds access in cgroup local storage can be crafted via tail calls. Given two programs each utilizing a cgroup local storage with a…
- risk 0.46cvss 7.0epss 0.00
A vulnerability has been identified in RUGGEDCOM i800 (All versions), RUGGEDCOM i801 (All versions), RUGGEDCOM i802 (All versions), RUGGEDCOM i803 (All versions), RUGGEDCOM M2100 (All versions), RUGGEDCOM M2200 (All versions), RUGGEDCOM M969 (All versions), RUGGEDCOM RMC30 (All…
- risk 0.46cvss 7.0epss 0.00
A vulnerability has been identified in SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions). The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into…
- risk 0.46cvss 7.1epss 0.00
A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0), SIMATIC…
- risk 0.44cvss 6.8epss 0.00
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versions < V2.17.1), RUGGEDCOM ROX RX1400 (All versions < V2.17.1), RUGGEDCOM ROX RX1500 (All versions < V2.17.1), RUGGEDCOM ROX RX1501 (All versions < V2.17.1),…
- risk 0.44cvss 6.7epss 0.00
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3). The affected application does not properly restrict permissions of the users. This could allow a lowly-privileged attacker to escalate their privileges.
- risk 0.44cvss 6.7epss 0.00
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3). The affected application searches for executable files in the application folder without proper validation. This could allow an attacker to execute arbitrary code with administrative…
- risk 0.44cvss 6.8epss 0.00
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions < V9.90), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions < V9.90), SIPROTEC 5…
- risk 0.44cvss 6.8epss 0.01
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.
- risk 0.44cvss 5.5epss 0.61
Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis,…
- risk 0.44cvss 6.7epss 0.00
A vulnerability has been identified in SIMATIC WinCC OA UI for Android (All versions < V3.15.10), SIMATIC WinCC OA UI for iOS (All versions < V3.15.10). Insufficient limitation of CONTROL script capabilities could allow read and write access from one HMI project cache folder to…
- risk 0.44cvss 6.8epss 0.02
Wi-Fi Protected Access (WPA and WPA2) allows reinstallation of the Station-To-Station-Link (STSL) Transient Key (STK) during the PeerKey handshake, allowing an attacker within radio range to replay, decrypt, or spoof frames.
- risk 0.44cvss 6.7epss 0.00
Siemens SICAM PAS before 8.07 does not properly restrict password data in the database, which makes it easier for local users to calculate passwords by leveraging unspecified database privileges.
- risk 0.43cvss 6.6epss 0.00
A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.9.0), RUGGEDCOM RMC8388NC V5.X (All versions < V5.9.0), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416Pv2 V5.X (All versions <…
- risk 0.43cvss 6.5epss 0.03
NTP before 4.2.8p6 and 4.3.x before 4.3.90, when configured in broadcast mode, allows man-in-the-middle attackers to conduct replay attacks by sniffing the network.
- risk 0.43cvss 6.6epss 0.02
A vulnerability has been identified in SIMATIC CP 1543-1 (All versions < V2.0.28), SIPLUS NET CP 1543-1 (All versions < V2.0.28). Users with elevated privileges to TIA-Portal and project data on the engineering station could possibly get privileged access on affected devices.
- risk 0.42cvss 6.5epss 0.00
A Stored HTML Injection vulnerability was discovered in the Smart Polling functionality due to improper validation of an input parameter. An authenticated user with limited privileges can push malicious remote strategies containing HTML tags through the sync. When a victim views…
- risk 0.42cvss 6.5epss 0.00
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.10), RTUM85 RTU Base (All versions < V26.10). The affected application contains denial-of-service (DoS) vulnerability. The remote operation mode is susceptible to a resource…
- risk 0.42cvss 6.5epss 0.00
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2)…
- risk 0.42cvss 6.5epss 0.00
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2),…
- risk 0.42cvss 6.5epss 0.00
A vulnerability has been identified in BACnet ATEC 550-440 (All versions), BACnet ATEC 550-441 (All versions), BACnet ATEC 550-445 (All versions), BACnet ATEC 550-446 (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an…
- risk 0.42cvss 6.5epss 0.00
A vulnerability has been identified in MS/TP Point Pickup Module (All versions). Affected devices improperly handle specific incoming BACnet MSTP messages. This could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a…
- risk 0.42cvss 6.5epss 0.00
A vulnerability has been identified in SIRIUS 3RK3 Modular Safety System (MSS) (All versions), SIRIUS Safety Relays 3SK2 (All versions). The affected devices do not encrypt data in transit. An attacker with network access could eavesdrop the connection and retrieve sensitive…
- risk 0.42cvss 6.5epss 0.01
A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0) (All versions < V4.7),…
- risk 0.42cvss 6.5epss 0.01
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85…
- risk 0.42cvss 6.5epss 0.01
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.40), SICORE Base system (All versions < V1.4.0). Affected devices allow a remote authenticated user or an unauthenticated user with physical access to downgrade the firmware of the…
- risk 0.42cvss 6.5epss 0.00
A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17…
- risk 0.42cvss 6.5epss 0.00
A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The Apache Lucene based query engine in the affected application lacks proper access controls. This could allow an authenticated user to query items beyond the user's allowed projects.
- risk 0.42cvss 6.5epss 0.01
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating…
- risk 0.42cvss 6.5epss 0.00
A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating…
- risk 0.42cvss 6.5epss 0.00
A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17…