VYPR

Vendor CVEs

Ge

All CVEs

134 total · sorted by risk
  • CVE-2023-0755CriFeb 23, 2023
    risk 0.65cvss 9.8epss 0.12

    The affected products are vulnerable to an improper validation of array index, which could allow an attacker to crash the server and remotely execute arbitrary code.

  • CVE-2020-27265CriJan 14, 2021
    risk 0.65cvss 9.8epss 0.10

    KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server:…

  • CVE-2016-5788CriNov 25, 2016
    risk 0.65cvss 10.0epss 0.02

    General Electric (GE) Bently Nevada 3500/22M USB with firmware before 5.0 and Bently Nevada 3500/22M Serial have open ports, which makes it easier for remote attackers to obtain privileged access via unspecified vectors.

  • CVE-2022-2825CriMar 29, 2023
    risk 0.64cvss 9.8epss 0.03

    This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue…

  • CVE-2023-0754CriFeb 23, 2023
    risk 0.64cvss 9.8epss 0.03

    The affected products are vulnerable to an integer overflow or wraparound, which could  allow an attacker to crash the server and remotely execute arbitrary code.

  • CVE-2022-46732CriJan 18, 2023
    risk 0.64cvss 9.8epss 0.01

    Even if the authentication fails for local service authentication, the requested command could still execute regardless of authentication status.

  • CVE-2022-43977CriJan 17, 2023
    risk 0.64cvss 9.8epss 0.01

    An issue was discovered on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. The debug port accessible via TCP (a qconn service) lacks access control.

  • CVE-2022-43976CriJan 17, 2023
    risk 0.64cvss 9.8epss 0.01

    An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p0_3.2.2.17p0_4.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication.

  • CVE-2022-24119CriDec 26, 2022
    risk 0.64cvss 9.8epss 0.01

    Certain General Electric Renewable Energy products have a hidden feature for unauthenticated remote access to the device configuration shell. This affects iNET and iNET II before 8.3.0.

  • CVE-2022-24117CriDec 26, 2022
    risk 0.64cvss 9.8epss 0.00

    Certain General Electric Renewable Energy products download firmware without an integrity check. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.

  • CVE-2022-24116CriDec 26, 2022
    risk 0.64cvss 9.8epss 0.00

    Certain General Electric Renewable Energy products have inadequate encryption strength. This affects iNET and iNET II before 8.3.0.

  • CVE-2021-27428CriMar 23, 2022
    risk 0.64cvss 9.8epss 0.01

    GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool – Enervista UR Setup. This UR Setup tool validates the authenticity and integrity of firmware file before uploading the UR IED. An illegitimate user could upgrade…

  • CVE-2021-27426CriMar 23, 2022
    risk 0.64cvss 9.8epss 0.01

    GE UR IED firmware versions prior to version 8.1x with “Basic” security variant does not allow the disabling of the “Factory Mode,” which is used for servicing the IED by a “Factory” user.

  • CVE-2020-25197CriMar 18, 2022
    risk 0.64cvss 9.8epss 0.03

    A code injection vulnerability exists in one of the webpages in GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06 that could allow an authenticated remote attacker to execute arbitrary code on the system.

  • CVE-2021-27440CriMar 25, 2021
    risk 0.64cvss 9.8epss 0.01

    The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).

  • CVE-2020-12017CriJun 2, 2020
    risk 0.64cvss 9.8epss 0.02

    GE Grid Solutions Reason RT Clocks, RT430, RT431, and RT434, all firmware versions prior to 08A05. The device’s vulnerability in the web application could allow multiple unauthenticated attacks that could cause serious impact. The vulnerability may allow an unauthenticated…

  • CVE-2019-6548CriMay 9, 2019
    risk 0.64cvss 9.8epss 0.01

    GE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the database. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.

  • CVE-2018-10611CriJun 4, 2018
    risk 0.64cvss 9.8epss 0.05

    Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services.

  • CVE-2017-14008CriMar 20, 2018
    risk 0.64cvss 9.8epss 0.03

    GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.

  • CVE-2017-14006CriMar 20, 2018
    risk 0.64cvss 9.8epss 0.02

    GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the…

  • CVE-2017-14004CriMar 20, 2018
    risk 0.64cvss 9.8epss 0.02

    GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.

  • CVE-2017-14002CriMar 20, 2018
    risk 0.64cvss 9.8epss 0.05

    GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected…

  • CVE-2018-5475CriFeb 19, 2018
    risk 0.64cvss 9.8epss 0.04

    A Stack-based Buffer Overflow issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified, which may allow remote code execution.

  • CVE-2018-5473CriFeb 19, 2018
    risk 0.64cvss 9.8epss 0.06

    An Improper Restriction of Operations within the Bounds of a Memory Buffer issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. The SSH functions of the device are vulnerable to buffer overflow conditions that may allow a remote…

  • CVE-2017-7905CriJun 30, 2017
    risk 0.64cvss 9.8epss 0.01

    A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware…

  • CVE-2016-2310CriJun 9, 2016
    risk 0.64cvss 9.8epss 0.03

    General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web…

  • CVE-2008-0174CriJan 29, 2008
    risk 0.64cvss 9.8epss 0.02

    GE Fanuc Proficy Real-Time Information Portal 2.6 and earlier uses HTTP Basic Authentication, which transmits usernames and passwords in base64-encoded cleartext and allows remote attackers to steal the passwords and gain privileges.

  • CVE-2016-0861HigFeb 5, 2016
    risk 0.61cvss 8.8epss 0.14

    General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to execute arbitrary commands via unspecified vectors.

  • CVE-2020-27267CriJan 14, 2021
    risk 0.60cvss 9.1epss 0.05

    KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server…

  • CVE-2020-27263CriJan 14, 2021
    risk 0.60cvss 9.1epss 0.05

    KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server:…

  • CVE-2023-5908CriNov 30, 2023
    risk 0.59cvss 9.1epss 0.01

    KEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.

  • CVE-2022-2848CriMar 29, 2023
    risk 0.59cvss 9.1epss 0.03

    This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kepware KEPServerEX 6.11.718.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of text encoding conversions. The issue…

  • CVE-2022-24118CriDec 26, 2022
    risk 0.59cvss 9.1epss 0.01

    Certain General Electric Renewable Energy products allow attackers to use a code to trigger a reboot into the factory default configuration. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.

  • CVE-2018-15362CriDec 7, 2018
    risk 0.59cvss 9.1epss 0.03

    XXE in GE Proficy Cimplicity GDS versions 9.0 R2, 9.5, 10.0

  • CVE-2020-36549HigJun 17, 2022
    risk 0.57cvss 8.8epss 0.00

    A vulnerability classified as critical was found in GE Voluson S8. Affected is the underlying Windows XP operating system. Missing patches might introduce an excessive attack surface. Access to the local network is required for this attack to succeed.

  • CVE-2021-27438HigMar 25, 2021
    risk 0.57cvss 8.8epss 0.01

    The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).

  • CVE-2019-13554HigApr 7, 2020
    risk 0.57cvss 8.8epss 0.01

    GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service.

  • CVE-2021-27430HigMar 23, 2022
    risk 0.55cvss 8.4epss 0.00

    GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR.

  • CVE-2012-6663HigJan 23, 2020
    risk 0.53cvss 7.5epss 0.09

    General Electric D20ME devices are not properly configured and reveal plaintext passwords.

  • CVE-2018-10615HigJun 4, 2018
    risk 0.53cvss 8.1epss 0.03

    Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform.

  • CVE-2023-4487HigSep 5, 2023
    risk 0.51cvss 7.8epss 0.00

    GE CIMPLICITY 2023 is by a process control vulnerability, which could allow a local attacker to insert malicious configuration files in the expected web server execution path to escalate privileges and gain full control of the HMI software.

  • CVE-2023-0598HigMar 16, 2023
    risk 0.51cvss 7.8epss 0.01

    GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI…

  • CVE-2022-3092HigDec 8, 2022
    risk 0.51cvss 7.8epss 0.00

    GE CIMPICITY versions 2022 and prior is vulnerable to an out-of-bounds write, which could allow an attacker to execute arbitrary code.

  • CVE-2022-3084HigDec 8, 2022
    risk 0.51cvss 7.8epss 0.00

    GE CIMPICITY versions 2022 and prior is vulnerable when data from a faulting address controls code flow starting at gmmiObj!CGmmiRootOptionTable, which could allow an attacker to execute arbitrary code.

  • CVE-2022-2952HigDec 7, 2022
    risk 0.51cvss 7.8epss 0.00

    GE CIMPICITY versions 2022 and prior is vulnerable when data from a faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code.

  • CVE-2022-2948HigDec 7, 2022
    risk 0.51cvss 7.8epss 0.00

    GE CIMPICITY versions 2022 and prior is vulnerable to a heap-based buffer overflow, which could allow an attacker to execute arbitrary code.

  • CVE-2022-2002HigDec 7, 2022
    risk 0.51cvss 7.8epss 0.00

    GE CIMPICITY versions 2022 and prior is vulnerable when data from faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code.

  • CVE-2021-27454HigMar 25, 2021
    risk 0.51cvss 7.8epss 0.00

    The software performs an operation at a privilege level higher than the minimum level required, which creates new weaknesses or amplifies the consequences of other weaknesses on the Reason DR60 (all firmware versions prior to 02A04.1).

  • CVE-2021-27452HigMar 25, 2021
    risk 0.51cvss 7.8epss 0.00

    The software contains a hard-coded password that could allow an attacker to take control of the merging unit using these hard-coded credentials on the MU320E (all firmware versions prior to v04A00.1).

  • CVE-2021-27450HigMar 25, 2021
    risk 0.51cvss 7.8epss 0.00

    SSH server configuration file does not implement some best practices. This could lead to a weakening of the SSH protocol strength, which could lead to additional misconfiguration or be leveraged as part of a larger attack on the MU320E (all firmware versions prior to v04A00.1).

Page 1 of 3