VYPR
Vendor

General Electric (GE)

Products
16
CVEs
17
Across products
26
Status
Private

Products

16

Recent CVEs

17
  • CVE-2016-5788CriNov 25, 2016
    risk 0.65cvss 10.0epss 0.02

    General Electric (GE) Bently Nevada 3500/22M USB with firmware before 5.0 and Bently Nevada 3500/22M Serial have open ports, which makes it easier for remote attackers to obtain privileged access via unspecified vectors.

  • CVE-2022-24119CriDec 26, 2022
    risk 0.64cvss 9.8epss 0.01

    Certain General Electric Renewable Energy products have a hidden feature for unauthenticated remote access to the device configuration shell. This affects iNET and iNET II before 8.3.0.

  • CVE-2022-24117CriDec 26, 2022
    risk 0.64cvss 9.8epss 0.00

    Certain General Electric Renewable Energy products download firmware without an integrity check. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.

  • CVE-2022-24116CriDec 26, 2022
    risk 0.64cvss 9.8epss 0.00

    Certain General Electric Renewable Energy products have inadequate encryption strength. This affects iNET and iNET II before 8.3.0.

  • CVE-2018-5475CriFeb 19, 2018
    risk 0.64cvss 9.8epss 0.04

    A Stack-based Buffer Overflow issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. Multiple stack-based buffer overflow vulnerabilities have been identified, which may allow remote code execution.

  • CVE-2018-5473CriFeb 19, 2018
    risk 0.64cvss 9.8epss 0.06

    An Improper Restriction of Operations within the Bounds of a Memory Buffer issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. The SSH functions of the device are vulnerable to buffer overflow conditions that may allow a remote…

  • CVE-2016-2310CriJun 9, 2016
    risk 0.64cvss 9.8epss 0.03

    General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web…

  • CVE-2016-0861HigFeb 5, 2016
    risk 0.61cvss 8.8epss 0.14

    General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to execute arbitrary commands via unspecified vectors.

  • CVE-2022-24118CriDec 26, 2022
    risk 0.59cvss 9.1epss 0.01

    Certain General Electric Renewable Energy products allow attackers to use a code to trigger a reboot into the factory default configuration. This affects iNET and iNET II before 8.3.0, SD before 6.4.7, TD220X before 2.0.16, and TD220MAX before 1.2.6.

  • CVE-2012-6663HigJan 23, 2020
    risk 0.53cvss 7.5epss 0.09

    General Electric D20ME devices are not properly configured and reveal plaintext passwords.

  • CVE-2022-23921HigFeb 25, 2022
    risk 0.49cvss 7.5epss 0.00

    Exploitation of this vulnerability may result in local privilege escalation and code execution. GE maintains exploitation of this vulnerability is only possible if the attacker has login access to a machine actively running CIMPLICITY, the CIMPLICITY server is not already…

  • CVE-2022-21798HigFeb 25, 2022
    risk 0.49cvss 7.5epss 0.01

    The affected product is vulnerable due to cleartext transmission of credentials seen in the CIMPLICITY network, which can be easily spoofed and used to log in to make operational changes to the system.

  • CVE-2016-9360MedFeb 13, 2017
    risk 0.44cvss 6.7epss 0.00

    An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if…

  • CVE-2016-5787MedJul 15, 2016
    risk 0.41cvss 6.3epss 0.00

    General Electric (GE) Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors.

  • CVE-2023-0898MedNov 7, 2023
    risk 0.34cvss 5.3epss 0.00

    General Electric MiCOM S1 Agile is vulnerable to an attacker achieving code execution by placing malicious DLL files in the directory of the application.

  • CVE-2022-24120MedDec 26, 2022
    risk 0.30cvss 4.6epss 0.00

    Certain General Electric Renewable Energy products store cleartext credentials in flash memory. This affects iNET and iNET II before 8.3.0.

  • CVE-2013-2823Nov 22, 2013
    risk 0.00cvss epss 0.01

    The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow physically proximate…