800xA Base
by Abb
CVEs (6)
| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2024-3036 | 0.00 | — | 0.00 | Jun 21, 2024 | Improper Input Validation vulnerability in ABB 800xA Base. An attacker who successfully exploited this vulnerability could cause services to crash by sending specifically crafted messages. This issue affects 800xA Base: from 6.0.0 through 6.1.1-2. | |||
| CVE-2020-8487 | 0.00 | — | 0.00 | Apr 29, 2020 | Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling. | |||
| CVE-2020-8486 | 0.00 | — | 0.00 | Apr 29, 2020 | Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling. | |||
| CVE-2020-8479 | 0.00 | — | 0.02 | Apr 29, 2020 | For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+… | |||
| CVE-2020-8473 | 0.00 | — | 0.00 | Apr 28, 2020 | Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could… | |||
| CVE-2020-8474 | 0.00 | — | 0.00 | Apr 22, 2020 | Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction. |
- CVE-2024-3036Jun 21, 2024risk 0.00cvss —epss 0.00
Improper Input Validation vulnerability in ABB 800xA Base. An attacker who successfully exploited this vulnerability could cause services to crash by sending specifically crafted messages. This issue affects 800xA Base: from 6.0.0 through 6.1.1-2.
- CVE-2020-8487Apr 29, 2020risk 0.00cvss —epss 0.00
Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
- CVE-2020-8486Apr 29, 2020risk 0.00cvss —epss 0.00
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling.
- CVE-2020-8479Apr 29, 2020risk 0.00cvss —epss 0.02
For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+…
- CVE-2020-8473Apr 28, 2020risk 0.00cvss —epss 0.00
Insufficient folder permissions used by system functions in ABB System 800xA Base (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploit the vulnerabilities could…
- CVE-2020-8474Apr 22, 2020risk 0.00cvss —epss 0.00
Weak Registry permissions in ABB System 800xA Base allow low privileged users to read and modify registry settings related to control system functionality, allowing an authenticated attacker to cause system functions to stop or malfunction.