Simatic Pcs7
CVEs (66)
| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2023-46099 | Med | 0.35 | 5.4 | 0.00 | Nov 14, 2023 | A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). There is a stored cross-site scripting vulnerability in the Administration Console of the affected product, that could allow an attacker with high privileges to inject Javascript code into the… | ||
| CVE-2020-7588 | Med | 0.35 | 5.3 | 0.02 | Jul 14, 2020 | A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3),… | ||
| CVE-2017-14023 | Med | 0.32 | 4.9 | 0.04 | Nov 6, 2017 | An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of… | ||
| CVE-2023-28829 | Low | 0.25 | 3.9 | 0.00 | Jun 13, 2023 | A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT… | ||
| CVE-2014-8552 | 0.00 | — | 0.02 | Nov 26, 2014 | The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets. | |||
| CVE-2014-8551 | 0.00 | — | 0.05 | Nov 26, 2014 | The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets. | |||
| CVE-2014-4686 | 0.00 | — | 0.01 | Jul 24, 2014 | The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then… | |||
| CVE-2014-4685 | 0.00 | — | 0.00 | Jul 24, 2014 | Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control. | |||
| CVE-2014-4684 | 0.00 | — | 0.01 | Jul 24, 2014 | The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433. | |||
| CVE-2014-4683 | 0.00 | — | 0.01 | Jul 24, 2014 | The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request. | |||
| CVE-2014-4682 | 0.00 | — | 0.02 | Jul 24, 2014 | The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request. | |||
| CVE-2013-3959 | 0.00 | — | 0.01 | Jun 14, 2013 | The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account… | |||
| CVE-2013-3958 | 0.00 | — | 0.02 | Jun 14, 2013 | The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request. | |||
| CVE-2013-3957 | 0.00 | — | 0.02 | Jun 14, 2013 | SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors. | |||
| CVE-2013-0679 | 0.00 | — | 0.02 | Mar 21, 2013 | Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname. | |||
| CVE-2013-0678 | 0.00 | — | 0.02 | Mar 21, 2013 | Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query. | |||
| CVE-2013-0677 | 0.00 | — | 0.02 | Mar 21, 2013 | The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file. | |||
| CVE-2013-0676 | 0.00 | — | 0.02 | Mar 21, 2013 | Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query. | |||
| CVE-2013-0675 | 0.00 | — | 0.01 | Mar 21, 2013 | Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet. | |||
| CVE-2013-0674 | 0.00 | — | 0.03 | Mar 21, 2013 | Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter. |
- risk 0.35cvss 5.4epss 0.00
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). There is a stored cross-site scripting vulnerability in the Administration Console of the affected product, that could allow an attacker with high privileges to inject Javascript code into the…
- risk 0.35cvss 5.3epss 0.02
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3),…
- risk 0.32cvss 4.9epss 0.04
An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of…
- risk 0.25cvss 3.9epss 0.00
A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT…
- CVE-2014-8552Nov 26, 2014risk 0.00cvss —epss 0.02
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.
- CVE-2014-8551Nov 26, 2014risk 0.00cvss —epss 0.05
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.
- CVE-2014-4686Jul 24, 2014risk 0.00cvss —epss 0.01
The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then…
- CVE-2014-4685Jul 24, 2014risk 0.00cvss —epss 0.00
Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.
- CVE-2014-4684Jul 24, 2014risk 0.00cvss —epss 0.01
The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433.
- CVE-2014-4683Jul 24, 2014risk 0.00cvss —epss 0.01
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.
- CVE-2014-4682Jul 24, 2014risk 0.00cvss —epss 0.02
The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request.
- CVE-2013-3959Jun 14, 2013risk 0.00cvss —epss 0.01
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account…
- CVE-2013-3958Jun 14, 2013risk 0.00cvss —epss 0.02
The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request.
- CVE-2013-3957Jun 14, 2013risk 0.00cvss —epss 0.02
SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors.
- CVE-2013-0679Mar 21, 2013risk 0.00cvss —epss 0.02
Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.
- CVE-2013-0678Mar 21, 2013risk 0.00cvss —epss 0.02
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query.
- CVE-2013-0677Mar 21, 2013risk 0.00cvss —epss 0.02
The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file.
- CVE-2013-0676Mar 21, 2013risk 0.00cvss —epss 0.02
Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query.
- CVE-2013-0675Mar 21, 2013risk 0.00cvss —epss 0.01
Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet.
- CVE-2013-0674Mar 21, 2013risk 0.00cvss —epss 0.03
Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.