CVE-2020-7588
Description
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.
Affected products
34< V3.2+ 2 more
- (no CPE)range: < V3.2
- (no CPE)range: All versions < V3.2
- cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*range: <3.2
< V15.1 Update 5+ 2 more
- (no CPE)range: < V15.1 Update 5
- (no CPE)range: All versions < V15.1 Update 5
- (no CPE)range: All versions < V16 Update 2
- Range: All versions < V3.0 SP1
All versions < V15.1 Update 4+ 2 more
- (no CPE)range: All versions < V15.1 Update 4
- (no CPE)range: All versions < V16 Update 1
- cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*
< V3.0 SP1+ 1 more
- (no CPE)range: < V3.0 SP1
- cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*
All versions < V3.2+ 1 more
- (no CPE)range: All versions < V3.2
- cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*range: <3.2
All versions < V2.6+ 1 more
- (no CPE)range: All versions < V2.6
- cpe:2.3:a:siemens:simatic_it_lms:*:*:*:*:*:*:*:*
All versions < V8.0+ 1 more
- (no CPE)range: All versions < V8.0
- cpe:2.3:a:siemens:simatic_it_production_suite:*:*:*:*:*:*:*:*
All versions < V11.3+ 1 more
- (no CPE)range: All versions < V11.3
- cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*range: <11.3
- Range: V8.0
cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*+ 1 more
- cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*range: <3.2
- (no CPE)range: All versions < V3.2
- cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*
- cpe:2.3:a:siemens:opcenter_rd\&l:8.0:*:*:*:*:*:*:*
- cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*
cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*+ 2 more
- cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*range: >=15,<=15.1
- cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*
- cpe:2.3:a:siemens:simatic_step_7:16:update_1:*:*:*:*:*:*
- cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*
- Siemens/Opcenter Intelligencev5Range: All versions < V3.3
- Siemens/SIMATIC Notifier Server for Windowsv5Range: All versions
- Siemens/Soft Starter ES V15.1v5Range: All versions < V15.1 Update 3
- Siemens/Soft Starter ES V16v5Range: All versions < V16 Update 1
Patches
Vulnerability mechanics
References
1- cert-portal.siemens.com/productcert/pdf/ssa-841348.pdfnvdVendor Advisory
News mentions
0No linked articles in our index yet.