| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2025-46121 | Cri | 0.64 | 9.8 | 0.01 | Jul 21, 2025 | An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, where the functions `stamgr_cfg_adpt_addStaFavourite` and `stamgr_cfg_adpt_addStaIot` pass a client hostname directly to snprintf as the format string. A remote attacker can… | ||
| CVE-2025-46120 | Cri | 0.64 | 9.8 | 0.01 | Jul 21, 2025 | An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.27 and 200.18.7.1.323, and in Ruckus ZoneDirector prior to 10.5.1.0.282, where a path-traversal flaw in the web interface lets the server execute attacker-supplied EJS templates outside permitted… | ||
| CVE-2020-22658 | Cri | 0.64 | 9.8 | 0.01 | Jan 20, 2023 | In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)… | ||
| CVE-2020-22654 | Cri | 0.64 | 9.8 | 0.00 | Jan 20, 2023 | In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)… | ||
| CVE-2025-46122 | Cri | 0.59 | 9.1 | 0.01 | Jul 21, 2025 | An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, where the authenticated diagnostics API endpoint `/admin/_cmdstat.jsp` passes attacker-controlled input to the shell without adequate validation, enabling a remote attacker to… | ||
| CVE-2025-46117 | Cri | 0.59 | 9.1 | 0.01 | Jul 21, 2025 | An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, and in Ruckus ZoneDirector prior to 10.5.1.0.279, where a hidden debug script `.ap_debug.sh` invoked from the restricted CLI does not properly sanitize its input, allowing an… | ||
| CVE-2025-46116 | Hig | 0.57 | 8.8 | 0.01 | Jul 21, 2025 | An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, and in Ruckus ZoneDirector prior to 10.5.1.0.279, where an authenticated attacker can disable the passphrase requirement for a hidden CLI command `!v54!` via a management API call… | ||
| CVE-2020-22662 | Hig | 0.49 | 7.5 | 0.01 | Jan 20, 2023 | In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)… | ||
| CVE-2020-22660 | Hig | 0.49 | 7.5 | 0.01 | Jan 20, 2023 | In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)… | ||
| CVE-2020-22659 | Hig | 0.49 | 7.5 | 0.00 | Jan 20, 2023 | In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)… | ||
| CVE-2020-22655 | Hig | 0.49 | 7.5 | 0.00 | Jan 20, 2023 | In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)… | ||
| CVE-2025-46123 | Hig | 0.47 | 7.2 | 0.01 | Jul 21, 2025 | An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, and in Ruckus ZoneDirector prior to 10.5.1.0.279, where the authenticated configuration endpoint `/admin/_conf.jsp` writes the Wi-Fi guest password to memory with snprintf using… | ||
| CVE-2020-22661 | Med | 0.42 | 6.5 | 0.01 | Jan 20, 2023 | In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)… | ||
| CVE-2025-46119 | Med | 0.41 | 6.3 | 0.00 | Jul 21, 2025 | An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.27 and 200.18.7.1.323, and in Ruckus ZoneDirector prior to 10.5.1.0.282, where an authenticated request to the management endpoint `/admin/_cmdstat.jsp` discloses the administrator password in a… | ||
| CVE-2020-21161 | Med | 0.40 | 6.1 | 0.01 | Jun 27, 2022 | Cross Site Scripting (XSS) vulnerability in Ruckus Wireless ZoneDirector 9.8.3.0. | ||
| CVE-2025-46118 | Med | 0.34 | 5.3 | 0.01 | Jul 21, 2025 | An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139 and in Ruckus ZoneDirector prior to 10.5.1.0.279, where hard-coded credentials for the ftpuser account provide FTP access to the controller, enabling a remote attacker to upload or… |
- risk 0.64cvss 9.8epss 0.01
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, where the functions `stamgr_cfg_adpt_addStaFavourite` and `stamgr_cfg_adpt_addStaIot` pass a client hostname directly to snprintf as the format string. A remote attacker can…
- risk 0.64cvss 9.8epss 0.01
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.27 and 200.18.7.1.323, and in Ruckus ZoneDirector prior to 10.5.1.0.282, where a path-traversal flaw in the web interface lets the server execute attacker-supplied EJS templates outside permitted…
- risk 0.64cvss 9.8epss 0.01
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)…
- risk 0.64cvss 9.8epss 0.00
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)…
- risk 0.59cvss 9.1epss 0.01
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, where the authenticated diagnostics API endpoint `/admin/_cmdstat.jsp` passes attacker-controlled input to the shell without adequate validation, enabling a remote attacker to…
- risk 0.59cvss 9.1epss 0.01
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, and in Ruckus ZoneDirector prior to 10.5.1.0.279, where a hidden debug script `.ap_debug.sh` invoked from the restricted CLI does not properly sanitize its input, allowing an…
- risk 0.57cvss 8.8epss 0.01
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, and in Ruckus ZoneDirector prior to 10.5.1.0.279, where an authenticated attacker can disable the passphrase requirement for a hidden CLI command `!v54!` via a management API call…
- risk 0.49cvss 7.5epss 0.01
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)…
- risk 0.49cvss 7.5epss 0.01
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)…
- risk 0.49cvss 7.5epss 0.00
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)…
- risk 0.49cvss 7.5epss 0.00
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)…
- risk 0.47cvss 7.2epss 0.01
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, and in Ruckus ZoneDirector prior to 10.5.1.0.279, where the authenticated configuration endpoint `/admin/_conf.jsp` writes the Wi-Fi guest password to memory with snprintf using…
- risk 0.42cvss 6.5epss 0.01
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300)…
- risk 0.41cvss 6.3epss 0.00
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.27 and 200.18.7.1.323, and in Ruckus ZoneDirector prior to 10.5.1.0.282, where an authenticated request to the management endpoint `/admin/_cmdstat.jsp` discloses the administrator password in a…
- risk 0.40cvss 6.1epss 0.01
Cross Site Scripting (XSS) vulnerability in Ruckus Wireless ZoneDirector 9.8.3.0.
- risk 0.34cvss 5.3epss 0.01
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139 and in Ruckus ZoneDirector prior to 10.5.1.0.279, where hard-coded credentials for the ftpuser account provide FTP access to the controller, enabling a remote attacker to upload or…