High severity8.8NVD Advisory· Published Jul 21, 2025· Updated Jun 17, 2026
CVE-2025-46116
CVE-2025-46116
Description
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, and in Ruckus ZoneDirector prior to 10.5.1.0.279, where an authenticated attacker can disable the passphrase requirement for a hidden CLI command !v54! via a management API call and then invoke it to escape the restricted shell and obtain a root shell on the controller.
AI Insight
LLM-synthesized narrative grounded in this CVE's description and references.
Affected products
4(expand)+ 1 more
- (no CPE)
- (no CPE)range: <200.15.6.212.14, <200.17.7.0.139
- Range: <10.5.1.0.279
Patches
Vulnerability mechanics
References
2- sector7.computest.nl/post/2025-07-ruckus-unleashed/nvdExploitThird Party Advisory
- support.ruckuswireless.com/security_bulletins/330nvdProduct
News mentions
0No linked articles in our index yet.