Real-Time Automation Controller (RTAC)
by Schweitzer Engineering Laboratories, Inc.
CVEs (11)
| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2023-31150 | Hig | 0.52 | 8.0 | 0.00 | May 10, 2023 | A Storing Passwords in a Recoverable Format vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) database system could allow an authenticated attacker to retrieve passwords. See SEL Service Bulletin dated 2022-11-15 for more… | ||
| CVE-2023-2310 | Med | 0.44 | 6.8 | 0.01 | May 10, 2023 | A Channel Accessible by Non-Endpoint vulnerability in the Schweitzer Engineering Laboratories SEL Real-Time Automation Controller (RTAC) could allow a remote attacker to perform a man-in-the-middle (MiTM) that could result in denial of service. See the ACSELERATOR RTAC SEL-5033… | ||
| CVE-2023-31161 | Med | 0.38 | 5.9 | 0.01 | May 10, 2023 | An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow an authenticated remote attacker to use internal resources, allowing a variety of potential effects. See SEL Service… | ||
| CVE-2023-31165 | Med | 0.28 | 4.3 | 0.00 | May 10, 2023 | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary… | ||
| CVE-2023-31164 | Med | 0.28 | 4.3 | 0.00 | May 10, 2023 | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary… | ||
| CVE-2023-31163 | Med | 0.28 | 4.3 | 0.00 | May 10, 2023 | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary… | ||
| CVE-2023-31160 | Med | 0.28 | 4.3 | 0.00 | May 10, 2023 | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary… | ||
| CVE-2023-31159 | Med | 0.28 | 4.3 | 0.00 | May 10, 2023 | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary… | ||
| CVE-2023-31158 | Med | 0.28 | 4.3 | 0.00 | May 10, 2023 | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary… | ||
| CVE-2023-31156 | Med | 0.28 | 4.3 | 0.00 | May 10, 2023 | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary… | ||
| CVE-2023-31166 | Med | 0.27 | 4.1 | 0.01 | May 10, 2023 | An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of… |
- risk 0.52cvss 8.0epss 0.00
A Storing Passwords in a Recoverable Format vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) database system could allow an authenticated attacker to retrieve passwords. See SEL Service Bulletin dated 2022-11-15 for more…
- risk 0.44cvss 6.8epss 0.01
A Channel Accessible by Non-Endpoint vulnerability in the Schweitzer Engineering Laboratories SEL Real-Time Automation Controller (RTAC) could allow a remote attacker to perform a man-in-the-middle (MiTM) that could result in denial of service. See the ACSELERATOR RTAC SEL-5033…
- risk 0.38cvss 5.9epss 0.01
An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow an authenticated remote attacker to use internal resources, allowing a variety of potential effects. See SEL Service…
- risk 0.28cvss 4.3epss 0.00
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…
- risk 0.28cvss 4.3epss 0.00
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…
- risk 0.28cvss 4.3epss 0.00
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…
- risk 0.28cvss 4.3epss 0.00
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…
- risk 0.28cvss 4.3epss 0.00
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…
- risk 0.28cvss 4.3epss 0.00
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…
- risk 0.28cvss 4.3epss 0.00
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…
- risk 0.27cvss 4.1epss 0.01
An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of…