  • CVE-2017-7928CriAug 7, 2017
    risk 0.65cvss 10.0epss 0.02

    An Improper Access Control issue was discovered in Schweitzer Engineering Laboratories (SEL) SEL-3620 and SEL-3622 Security Gateway Versions R202 and, R203, R203-V1, R203-V2 and, R204, R204-V1. The device does not properly enforce access control while configured for NAT port…

  • CVE-2021-47731CriDec 9, 2025
    risk 0.64cvss 9.8epss 0.01

    Selea Targa IP OCR-ANPR Camera contains a hard-coded developer password vulnerability that allows unauthorized configuration access through an undocumented page. Attackers can exploit the hidden endpoint by using the hard-coded password 'Selea781830' to enable configuration…

  • CVE-2021-47728CriDec 9, 2025
    risk 0.64cvss 9.8epss 0.03

    Selea Targa IP OCR-ANPR Camera contains an unauthenticated command injection vulnerability in utils.php that allows remote attackers to execute arbitrary shell commands. Attackers can exploit the 'addr' and 'port' parameters to inject commands and gain www-data user access…

  • CVE-2018-10600CriJul 24, 2018
    risk 0.64cvss 9.8epss 0.02

    SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure and retrieval of arbitrary data, arbitrary code execution (in certain situations on specific platforms), and denial of service attacks.

  • CVE-2025-34022CriJun 20, 2025
    risk 0.61cvss epss 0.01

    A path traversal vulnerability exists in multiple models of Selea Targa IP OCR-ANPR cameras, including iZero, Targa 512, Targa 504, Targa Semplice, Targa 704 TKM, Targa 805, Targa 710 INOX, Targa 750, and Targa 704 ILB. The /common/get_file.php script in the “Download Archive…

  • CVE-2023-31149CriMay 10, 2023
    risk 0.59cvss 9.1epss 0.01

    An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to execute arbitrary code. See SEL Service Bulletin dated 2022-11-15 for more details. …

  • CVE-2023-31148CriMay 10, 2023
    risk 0.59cvss 9.1epss 0.01

    An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to execute arbitrary code. See SEL Service Bulletin dated 2022-11-15 for more details.

  • CVE-2021-47730HigDec 9, 2025
    risk 0.57cvss 8.8epss 0.00

    Selea Targa IP OCR-ANPR Camera contains a cross-site request forgery vulnerability that allows attackers to create administrative users without authentication. Attackers can craft a malicious web page that submits a form to add a new admin user with full system privileges when a…

  • CVE-2023-31175HigAug 31, 2023
    risk 0.57cvss 8.8epss 0.00

    An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system. See Instruction Manual Appendix A and Appendix E…

  • CVE-2018-10604HigJul 24, 2018
    risk 0.57cvss 8.8epss 0.02

    SEL Compass version 3.0.5.1 and prior allows all users full access to the SEL Compass directory, which may allow modification or overwriting of files within the Compass installation folder, resulting in escalation of privilege and/or malicious code execution.

  • CVE-2020-36903HigDec 31, 2025
    risk 0.55cvss 8.4epss 0.00

    Selea CarPlateServer 4.0.1.6 contains an unquoted service path vulnerability in the Windows service configuration that allows local users to potentially execute code with elevated privileges. Attackers can exploit the service's unquoted binary path by inserting malicious code in…

  • CVE-2023-34392HigAug 31, 2023
    risk 0.53cvss 8.2epss 0.00

    A Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator. See Instruction Manual Appendix A…

  • CVE-2023-31150HigMay 10, 2023
    risk 0.52cvss 8.0epss 0.00

    A Storing Passwords in a Recoverable Format vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) database system could allow an authenticated attacker to retrieve passwords. See SEL Service Bulletin dated 2022-11-15 for more…

  • CVE-2018-10608HigJul 24, 2018
    risk 0.52cvss 7.5epss 0.08

    SEL AcSELerator Architect version 2.2.24.0 and prior can be exploited when the AcSELerator Architect FTP client connects to a malicious FTP server, which may cause denial of service via 100% CPU utilization. Restart of the application is required.

  • CVE-2025-34021HigJun 20, 2025
    risk 0.51cvss epss 0.01

    A server-side request forgery (SSRF) vulnerability exists in multiple Selea Targa IP OCR-ANPR camera models, including iZero, Targa 512, Targa 504, Targa Semplice, Targa 704 TKM, Targa 805, Targa 710 INOX, Targa 750, and Targa 704 ILB. The application fails to validate…

  • CVE-2023-31173HigAug 31, 2023
    risk 0.50cvss 7.7epss 0.00

    Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid…

  • CVE-2020-36904HigDec 31, 2025
    risk 0.49cvss 7.5epss 0.00

    Selea CarPlateServer 4.0.1.6 contains a remote program execution vulnerability that allows attackers to execute arbitrary Windows binaries by manipulating the NO_LIST_EXE_PATH configuration parameter. Attackers can bypass authentication through the /cps/ endpoint and modify…

  • CVE-2023-31176HigNov 30, 2023
    risk 0.49cvss 7.5epss 0.01

    An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session tokens and bypass authentication.  See product Instruction Manual Appendix A dated 20230830 for more details.

  • CVE-2023-34391HigAug 31, 2023
    risk 0.48cvss 7.4epss 0.00

    Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths. See Instruction Manual Appendix A [Cybersecurity] tag dated 20230522 for more…

  • CVE-2023-31174HigAug 31, 2023
    risk 0.48cvss 7.4epss 0.00

    A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix…