5| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2022-31491 | Cri | 0.65 | 10.0 | 0.00 | Aug 22, 2025 | Voltronic Power ViewPower through 1.04-24215, ViewPower Pro through 2.0-22165, and PowerShield Netguard before 1.04-23292 allows a remote attacker to run arbitrary code via an unspecified web interface related to detection of a managed UPS shutting down. An unauthenticated attacker can use this to run arbitrary code immediately regardless of any managed UPS state or presence. | ||
| CVE-2026-22192 | Cri | 0.64 | 9.9 | 0.00 | Mar 13, 2026 | Voltronic Power SNMP Web Pro version 1.1 contains an authentication bypass vulnerability that allows unauthenticated attackers to access privileged management functions by manipulating browser localStorage values. Attackers can modify client-side authentication state to bypass server-side access controls and gain unauthorized access to protected management functionality without valid credentials. | ||
| CVE-2022-43110 | Cri | 0.64 | 9.8 | 0.00 | Aug 22, 2025 | Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. | ||
| CVE-2026-22199 | Hig | 0.49 | 7.5 | 0.00 | Mar 13, 2026 | Voltronic Power SNMP Web Pro version 1.1 contains a pre-authentication path traversal vulnerability in the upload.cgi endpoint that allows unauthenticated attackers to read arbitrary files on the device filesystem by supplying directory traversal sequences in the params parameter. Attackers can exploit this vulnerability to disclose sensitive files such as password hashes, which can be cracked offline to obtain root-level access and enable full system compromise. | ||
| CVE-2025-65287 | 0.00 | — | 0.00 | Dec 9, 2025 | An unauthenticated directory traversal vulnerability in cgi-bin/upload.cgi in SNMP Web Pro 1.1 allows a remote attacker to read arbitrary files. The CGI concatenates the user-supplied params directly onto the base path (/var/www/files/userScript/) using memcpy + strcat without validation or canonicalization, enabling ../ sequences to escape the intended directory. The download branch also echoes the unsanitized params into Content-Disposition, introducing header-injection risk. |
- risk 0.65cvss 10.0epss 0.00
Voltronic Power ViewPower through 1.04-24215, ViewPower Pro through 2.0-22165, and PowerShield Netguard before 1.04-23292 allows a remote attacker to run arbitrary code via an unspecified web interface related to detection of a managed UPS shutting down. An unauthenticated attacker can use this to run arbitrary code immediately regardless of any managed UPS state or presence.
- risk 0.64cvss 9.9epss 0.00
Voltronic Power SNMP Web Pro version 1.1 contains an authentication bypass vulnerability that allows unauthenticated attackers to access privileged management functions by manipulating browser localStorage values. Attackers can modify client-side authentication state to bypass server-side access controls and gain unauthorized access to protected management functionality without valid credentials.
- risk 0.64cvss 9.8epss 0.00
Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.
- risk 0.49cvss 7.5epss 0.00
Voltronic Power SNMP Web Pro version 1.1 contains a pre-authentication path traversal vulnerability in the upload.cgi endpoint that allows unauthenticated attackers to read arbitrary files on the device filesystem by supplying directory traversal sequences in the params parameter. Attackers can exploit this vulnerability to disclose sensitive files such as password hashes, which can be cracked offline to obtain root-level access and enable full system compromise.
- CVE-2025-65287Dec 9, 2025risk 0.00cvss —epss 0.00
An unauthenticated directory traversal vulnerability in cgi-bin/upload.cgi in SNMP Web Pro 1.1 allows a remote attacker to read arbitrary files. The CGI concatenates the user-supplied params directly onto the base path (/var/www/files/userScript/) using memcpy + strcat without validation or canonicalization, enabling ../ sequences to escape the intended directory. The download branch also echoes the unsanitized params into Content-Disposition, introducing header-injection risk.