Vendor CVEs
Tenda
All CVEs
2,140 total · sorted by risk| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2023-38932 | Cri | 0.64 | 9.8 | 0.01 | Aug 7, 2023 | Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter in the SafeEmailFilter function. | ||
| CVE-2023-38931 | Cri | 0.64 | 9.8 | 0.01 | Aug 7, 2023 | Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the… | ||
| CVE-2023-38930 | Cri | 0.64 | 9.8 | 0.01 | Aug 7, 2023 | Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. | ||
| CVE-2023-38929 | Cri | 0.64 | 9.8 | 0.01 | Aug 7, 2023 | Tenda 4G300 v1.01.42 was discovered to contain a stack overflow via the page parameter at /VirtualSer. | ||
| CVE-2023-37723 | Cri | 0.64 | 9.8 | 0.01 | Jul 14, 2023 | Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting. | ||
| CVE-2023-37722 | Cri | 0.64 | 9.8 | 0.01 | Jul 14, 2023 | Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeUrlFilter. | ||
| CVE-2023-37721 | Cri | 0.64 | 9.8 | 0.01 | Jul 14, 2023 | Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeMacFilter. | ||
| CVE-2023-37719 | Cri | 0.64 | 9.8 | 0.01 | Jul 14, 2023 | Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromP2pListFilter. | ||
| CVE-2023-37718 | Cri | 0.64 | 9.8 | 0.01 | Jul 14, 2023 | Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter. | ||
| CVE-2023-37717 | Cri | 0.64 | 9.8 | 0.01 | Jul 14, 2023 | Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient. | ||
| CVE-2023-37716 | Cri | 0.64 | 9.8 | 0.01 | Jul 14, 2023 | Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting. | ||
| CVE-2023-37715 | Cri | 0.64 | 9.8 | 0.01 | Jul 14, 2023 | Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm. | ||
| CVE-2023-37714 | Cri | 0.64 | 9.8 | 0.01 | Jul 14, 2023 | Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic. | ||
| CVE-2023-37712 | Cri | 0.64 | 9.8 | 0.01 | Jul 10, 2023 | Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function. | ||
| CVE-2023-37711 | Cri | 0.64 | 9.8 | 0.01 | Jul 10, 2023 | Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function. | ||
| CVE-2023-37710 | Cri | 0.64 | 9.8 | 0.01 | Jul 10, 2023 | Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function. | ||
| CVE-2023-37707 | Cri | 0.64 | 9.8 | 0.01 | Jul 10, 2023 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. | ||
| CVE-2023-37706 | Cri | 0.64 | 9.8 | 0.01 | Jul 10, 2023 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function. | ||
| CVE-2023-37705 | Cri | 0.64 | 9.8 | 0.01 | Jul 10, 2023 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function. | ||
| CVE-2023-37704 | Cri | 0.64 | 9.8 | 0.01 | Jul 10, 2023 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. | ||
| CVE-2023-37703 | Cri | 0.64 | 9.8 | 0.01 | Jul 10, 2023 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. | ||
| CVE-2023-37702 | Cri | 0.64 | 9.8 | 0.01 | Jul 10, 2023 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function. | ||
| CVE-2023-37701 | Cri | 0.64 | 9.8 | 0.01 | Jul 10, 2023 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. | ||
| CVE-2023-37700 | Cri | 0.64 | 9.8 | 0.01 | Jul 10, 2023 | Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. | ||
| CVE-2023-37144 | Cri | 0.64 | 9.8 | 0.02 | Jul 7, 2023 | Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac. | ||
| CVE-2023-34566 | Cri | 0.64 | 9.8 | 0.01 | Jun 8, 2023 | Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo. | ||
| CVE-2023-33675 | Cri | 0.64 | 9.8 | 0.01 | Jun 2, 2023 | Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function. | ||
| CVE-2023-33673 | Cri | 0.64 | 9.8 | 0.01 | Jun 2, 2023 | Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function. | ||
| CVE-2023-33671 | Cri | 0.64 | 9.8 | 0.01 | Jun 2, 2023 | Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function. | ||
| CVE-2023-33670 | Cri | 0.64 | 9.8 | 0.01 | Jun 2, 2023 | Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function. | ||
| CVE-2023-33669 | Cri | 0.64 | 9.8 | 0.02 | Jun 2, 2023 | Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function. | ||
| CVE-2023-31587 | Cri | 0.64 | 9.8 | 0.02 | May 16, 2023 | Tenda AC5 router V15.03.06.28 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac. | ||
| CVE-2023-30354 | Cri | 0.64 | 9.8 | 0.00 | May 10, 2023 | Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 does not defend against physical access to U-Boot via the UART: the Wi-Fi password is shown, and the hardcoded boot password can be inserted for console access. | ||
| CVE-2023-30353 | Cri | 0.64 | 9.8 | 0.01 | May 10, 2023 | Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 allows unauthenticated remote code execution via an XML document. | ||
| CVE-2023-30352 | Cri | 0.64 | 9.8 | 0.01 | May 10, 2023 | Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for the RTSP feed. | ||
| CVE-2023-30135 | Cri | 0.64 | 9.8 | 0.02 | May 5, 2023 | Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName parameter in the setUsbUnload function. | ||
| CVE-2023-30378 | Cri | 0.64 | 9.8 | 0.01 | Apr 24, 2023 | In Tenda AC15 V15.03.05.19, the function "sub_8EE8" contains a stack-based buffer overflow vulnerability. | ||
| CVE-2023-30376 | Cri | 0.64 | 9.8 | 0.01 | Apr 24, 2023 | In Tenda AC15 V15.03.05.19, the function "henan_pppoe_user" contains a stack-based buffer overflow vulnerability. | ||
| CVE-2023-30375 | Cri | 0.64 | 9.8 | 0.01 | Apr 24, 2023 | In Tenda AC15 V15.03.05.19, the function "getIfIp" contains a stack-based buffer overflow vulnerability. | ||
| CVE-2023-30373 | Cri | 0.64 | 9.8 | 0.01 | Apr 24, 2023 | In Tenda AC15 V15.03.05.19, the function "xian_pppoe_user" contains a stack-based buffer overflow vulnerability. | ||
| CVE-2023-30372 | Cri | 0.64 | 9.8 | 0.01 | Apr 24, 2023 | In Tenda AC15 V15.03.05.19, The function "xkjs_ver32" contains a stack-based buffer overflow vulnerability. | ||
| CVE-2023-30371 | Cri | 0.64 | 9.8 | 0.01 | Apr 24, 2023 | In Tenda AC15 V15.03.05.19, the function "sub_ED14" contains a stack-based buffer overflow vulnerability. | ||
| CVE-2023-30370 | Cri | 0.64 | 9.8 | 0.01 | Apr 24, 2023 | In Tenda AC15 V15.03.05.19, the function GetValue contains a stack-based buffer overflow vulnerability. | ||
| CVE-2023-30369 | Cri | 0.64 | 9.8 | 0.01 | Apr 24, 2023 | Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow. | ||
| CVE-2023-30368 | Cri | 0.64 | 9.8 | 0.01 | Apr 24, 2023 | Tenda AC5 V15.03.06.28 is vulnerable to Buffer Overflow via the initWebs function. | ||
| CVE-2023-27021 | Cri | 0.64 | 9.8 | 0.01 | Apr 7, 2023 | Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||
| CVE-2023-27020 | Cri | 0.64 | 9.8 | 0.01 | Apr 7, 2023 | Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||
| CVE-2023-27019 | Cri | 0.64 | 9.8 | 0.01 | Apr 7, 2023 | Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_458FBC function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||
| CVE-2023-27018 | Cri | 0.64 | 9.8 | 0.01 | Apr 7, 2023 | Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45EC1C function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||
| CVE-2023-27017 | Cri | 0.64 | 9.8 | 0.01 | Apr 7, 2023 | Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45DC58 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. |
- risk 0.64cvss 9.8epss 0.01
Tenda F1202 V1.2.0.9, PA202 V1.1.2.5, PW201A V1.1.2.5 and FH1202 V1.2.0.9 were discovered to contain a stack overflow via the page parameter in the SafeEmailFilter function.
- risk 0.64cvss 9.8epss 0.01
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the…
- risk 0.64cvss 9.8epss 0.01
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
- risk 0.64cvss 9.8epss 0.01
Tenda 4G300 v1.01.42 was discovered to contain a stack overflow via the page parameter at /VirtualSer.
- risk 0.64cvss 9.8epss 0.01
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting.
- risk 0.64cvss 9.8epss 0.01
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeUrlFilter.
- risk 0.64cvss 9.8epss 0.01
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeMacFilter.
- risk 0.64cvss 9.8epss 0.01
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromP2pListFilter.
- risk 0.64cvss 9.8epss 0.01
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter.
- risk 0.64cvss 9.8epss 0.01
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
- risk 0.64cvss 9.8epss 0.01
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
- risk 0.64cvss 9.8epss 0.01
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function frmL7ProtForm.
- risk 0.64cvss 9.8epss 0.01
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.
- risk 0.64cvss 9.8epss 0.01
Tenda AC1206 V15.03.06.23, F1202 V1.2.0.20(408), and FH1202 V1.2.0.20(408) were discovered to contain a stack overflow in the page parameter in the fromSetIpBind function.
- risk 0.64cvss 9.8epss 0.01
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the deviceId parameter in the saveParentControlInfo function.
- risk 0.64cvss 9.8epss 0.01
Tenda AC1206 V15.03.06.23 and AC10 V15.03.06.47 were discovered to contain a stack overflow in the wpapsk_crypto parameter in the fromSetWirelessRepeat function.
- risk 0.64cvss 9.8epss 0.01
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function.
- risk 0.64cvss 9.8epss 0.01
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function.
- risk 0.64cvss 9.8epss 0.01
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromAddressNat function.
- risk 0.64cvss 9.8epss 0.01
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
- risk 0.64cvss 9.8epss 0.01
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
- risk 0.64cvss 9.8epss 0.01
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function.
- risk 0.64cvss 9.8epss 0.01
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
- risk 0.64cvss 9.8epss 0.01
Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.
- risk 0.64cvss 9.8epss 0.02
Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac.
- risk 0.64cvss 9.8epss 0.01
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo.
- risk 0.64cvss 9.8epss 0.01
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function.
- risk 0.64cvss 9.8epss 0.01
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
- risk 0.64cvss 9.8epss 0.01
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function.
- risk 0.64cvss 9.8epss 0.01
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function.
- risk 0.64cvss 9.8epss 0.02
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function.
- risk 0.64cvss 9.8epss 0.02
Tenda AC5 router V15.03.06.28 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac.
- risk 0.64cvss 9.8epss 0.00
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 does not defend against physical access to U-Boot via the UART: the Wi-Fi password is shown, and the hardcoded boot password can be inserted for console access.
- risk 0.64cvss 9.8epss 0.01
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 allows unauthenticated remote code execution via an XML document.
- risk 0.64cvss 9.8epss 0.01
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for the RTSP feed.
- risk 0.64cvss 9.8epss 0.02
Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName parameter in the setUsbUnload function.
- risk 0.64cvss 9.8epss 0.01
In Tenda AC15 V15.03.05.19, the function "sub_8EE8" contains a stack-based buffer overflow vulnerability.
- risk 0.64cvss 9.8epss 0.01
In Tenda AC15 V15.03.05.19, the function "henan_pppoe_user" contains a stack-based buffer overflow vulnerability.
- risk 0.64cvss 9.8epss 0.01
In Tenda AC15 V15.03.05.19, the function "getIfIp" contains a stack-based buffer overflow vulnerability.
- risk 0.64cvss 9.8epss 0.01
In Tenda AC15 V15.03.05.19, the function "xian_pppoe_user" contains a stack-based buffer overflow vulnerability.
- risk 0.64cvss 9.8epss 0.01
In Tenda AC15 V15.03.05.19, The function "xkjs_ver32" contains a stack-based buffer overflow vulnerability.
- risk 0.64cvss 9.8epss 0.01
In Tenda AC15 V15.03.05.19, the function "sub_ED14" contains a stack-based buffer overflow vulnerability.
- risk 0.64cvss 9.8epss 0.01
In Tenda AC15 V15.03.05.19, the function GetValue contains a stack-based buffer overflow vulnerability.
- risk 0.64cvss 9.8epss 0.01
Tenda AC15 V15.03.05.19 is vulnerable to Buffer Overflow.
- risk 0.64cvss 9.8epss 0.01
Tenda AC5 V15.03.06.28 is vulnerable to Buffer Overflow via the initWebs function.
- risk 0.64cvss 9.8epss 0.01
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
- risk 0.64cvss 9.8epss 0.01
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
- risk 0.64cvss 9.8epss 0.01
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_458FBC function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
- risk 0.64cvss 9.8epss 0.01
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45EC1C function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
- risk 0.64cvss 9.8epss 0.01
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45DC58 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Page 8 of 43