Vendor CVEs
Siemens Foundation
All CVEs
2,430 total · sorted by risk| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2023-48429 | Low | 0.18 | 2.7 | 0.01 | Dec 12, 2023 | A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The… | ||
| CVE-2023-44321 | Low | 0.18 | 2.7 | 0.01 | Nov 14, 2023 | Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available… | ||
| CVE-2023-27410 | Low | 0.18 | 2.7 | 0.01 | May 9, 2023 | A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A heap-based buffer overflow vulnerability was found in the `edgebox_web_app` binary. The binary will crash if supplied with a backup password longer than 255 characters. This could allow an… | ||
| CVE-2022-46143 | Low | 0.18 | 2.7 | 0.01 | Dec 13, 2022 | Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data. | ||
| CVE-2019-13922 | Low | 0.18 | 2.7 | 0.01 | Sep 13, 2019 | A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the… | ||
| CVE-2024-41985 | Low | 0.17 | 2.6 | 0.00 | Aug 12, 2025 | A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not expire the session without logout. This… | ||
| CVE-2024-41984 | Low | 0.17 | 2.6 | 0.00 | Aug 12, 2025 | A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application improperly handles error while accessing an… | ||
| CVE-2025-40570 | Low | 0.16 | 2.4 | 0.00 | Aug 12, 2025 | A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V10.0), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MU85… | ||
| CVE-2023-27409 | Low | 0.16 | 2.5 | 0.00 | May 9, 2023 | A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A path traversal vulnerability was found in the `deviceinfo` binary via the `mac` parameter. This could allow an authenticated attacker with access to the SSH interface on the affected device to read… | ||
| CVE-2016-7960 | Low | 0.16 | 2.5 | 0.00 | Oct 13, 2016 | Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors. | ||
| CVE-2016-5849 | Low | 0.16 | 2.5 | 0.00 | Jul 4, 2016 | Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage. | ||
| CVE-2025-8732 | Low | 0.14 | 3.3 | 0.00 | Aug 8, 2025 | A vulnerability was found in libxml2 up to 2.14.5. It has been declared as problematic. This vulnerability affects the function xmlParseSGMLCatalog of the component xmlcatalog. The manipulation leads to uncontrolled recursion. Attacking locally is a requirement. The exploit has… | ||
| CVE-2021-22898 | Low | 0.14 | 3.1 | 0.04 | Jun 11, 2021 | curl 7.7 through 7.76.1 suffers from an information disclosure when the `-t` command line option, known as `CURLOPT_TELNETOPTIONS` in libcurl, is used to send variable=content pairs to TELNET servers. Due to a flaw in the option parser for sending NEW_ENV variables, libcurl… | ||
| CVE-2015-5374 | 0.09 | — | 0.74 | Jul 18, 2015 | A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03;… | |||
| CVE-2003-0190 | 0.09 | — | 0.77 | May 12, 2003 | OpenSSH-portable (OpenSSH) 3.6.1p1 and earlier with PAM support enabled immediately sends an error message when a user does not exist, which allows remote attackers to determine valid usernames via a timing attack. | |||
| CVE-2026-47192 | Low | 0.07 | — | 0.00 | Aug 14, 2026 | kas is a setup tool for bitbake based projects. Starting in version 4.8 and prior to version 5.3, kas checks out and processes repositories regarding configuration includes prior to validating signatures of those repositories. This may allow to replace on original repository… | ||
| CVE-2026-47191 | Low | 0.07 | — | 0.00 | Aug 14, 2026 | kas is a setup tool for bitbake based projects. Prior to version 5.3, when relying solely on a git commit ID (SHA-1 or SHA-256) to qualify if a checkout of a repository is equivalent to the state validated while adding its commit ID to a kas configuration, users may be tricked… | ||
| CVE-2012-1803 | 0.07 | — | 0.49 | Apr 28, 2012 | RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing… | |||
| CVE-2021-22901 | Hig | 0.05 | 8.1 | 0.60 | Jun 11, 2021 | curl 7.75.0 through 7.76.1 suffers from a use-after-free vulnerability resulting in already freed memory being used when a TLS 1.3 session ticket arrives over a connection. A malicious server can use this in rare unfortunate circumstances to potentially reach remote code… | ||
| CVE-2019-12815 | Cri | 0.05 | 9.8 | 0.58 | Jul 19, 2019 | An arbitrary file copy vulnerability in mod_copy in ProFTPD up to 1.3.5b allows for remote code execution and information disclosure without authentication, a related issue to CVE-2015-3306. | ||
| CVE-2014-2908 | 0.05 | — | 0.21 | Apr 25, 2014 | Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | |||
| CVE-2014-5074 | 0.04 | — | 0.10 | Aug 17, 2014 | Siemens SIMATIC S7-1500 CPU devices with firmware before 1.6 allow remote attackers to cause a denial of service (device restart and STOP transition) via crafted TCP packets. | |||
| CVE-2012-5409 | 0.04 | — | 0.16 | Nov 1, 2012 | AscoServer.exe in the server in Siemens SiPass integrated MP2.6 and earlier does not properly handle IOCP RPC messages received over an Ethernet network, which allows remote attackers to write data to any memory location and consequently execute arbitrary code via crafted… | |||
| CVE-2012-2441 | 0.04 | — | 0.09 | Apr 28, 2012 | RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH… | |||
| CVE-2011-4879 | 0.04 | — | 0.13 | Feb 3, 2012 | miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does… | |||
| CVE-2011-4878 | 0.04 | — | 0.12 | Feb 3, 2012 | Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime… | |||
| CVE-2011-4877 | 0.04 | — | 0.08 | Feb 3, 2012 | HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows… | |||
| CVE-2011-4876 | 0.04 | — | 0.10 | Feb 3, 2012 | Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when… | |||
| CVE-2011-4875 | 0.04 | — | 0.14 | Feb 3, 2012 | Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when… | |||
| CVE-2011-4531 | 0.04 | — | 0.09 | Jan 8, 2012 | Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allows remote attackers to cause a denial of service (NULL pointer dereference and daemon crash) via crafted content in a (1) get_target_ocx_param or (2) send_target_ocx_param command. | |||
| CVE-2011-4529 | 0.04 | — | 0.07 | Jan 8, 2012 | Multiple buffer overflows in Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allow remote attackers to execute arbitrary code via a long serialid field in an _licensekey command, as demonstrated by the (1) check_licensekey or (2) read_licensekey command. | |||
| CVE-2002-1483 | 0.04 | — | 0.08 | Apr 22, 2003 | db4web_c and db4web_c.exe programs in DB4Web 3.4 and 3.6 allow remote attackers to read arbitrary files via an HTTP request whose argument is a filename of the form (1) C: (drive letter), (2) //absolute/path (double-slash), or (3) .. (dot-dot). | |||
| CVE-2022-25236 | Cri | 0.03 | 9.8 | 0.36 | Feb 16, 2022 | xmlparse.c in Expat (aka libexpat) before 2.4.5 allows attackers to insert namespace-separator characters into namespace URIs. | ||
| CVE-2011-4532 | 0.03 | — | 0.04 | Jan 8, 2012 | Absolute path traversal vulnerability in the ALMListView.ALMListCtrl ActiveX control in almaxcx.dll in the graphical user interface in Siemens Automation License Manager (ALM) 2.0 through 5.1+SP1+Upd2 allows remote attackers to overwrite arbitrary files via the Save method. | |||
| CVE-2011-4530 | 0.03 | — | 0.04 | Jan 8, 2012 | Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 does not properly copy fields obtained from clients, which allows remote attackers to cause a denial of service (exception and daemon crash) via long fields, as demonstrated by fields to the (1)… | |||
| CVE-2009-3322 | 0.03 | — | 0.03 | Sep 23, 2009 | The Siemens Gigaset SE361 WLAN router allows remote attackers to cause a denial of service (device reboot) via a flood of crafted TCP packets to port 1723. | |||
| CVE-2008-7065 | 0.03 | — | 0.04 | Aug 25, 2009 | Siemens C450 IP and C475 IP VoIP devices allow remote attackers to cause a denial of service (disconnected calls and device reboot) via a crafted SIP packet to UDP port 5060. | |||
| CVE-2008-6916 | 0.03 | — | 0.04 | Aug 7, 2009 | Siemens SpeedStream 5200 with NetPort Software 1.1 allows remote attackers to bypass authentication via an invalid Host header, possibly involving a trailing dot in the hostname. | |||
| CVE-2009-1152 | 0.03 | — | 0.05 | Mar 26, 2009 | Siemens Gigaset SE461 WiMAX router 1.5-BL024.9.6401, and possibly other versions, allows remote attackers to cause a denial of service (device restart and loss of configuration) by connecting to TCP port 53, then closing the connection. | |||
| CVE-2004-2626 | 0.03 | — | 0.03 | Dec 31, 2004 | GUI overlay vulnerability in the Java API in Siemens S55 cellular phones allows remote attackers to send unauthorized SMS messages by overlaying a confirmation message with a malicious message. | |||
| CVE-2001-0384 | 0.03 | — | 0.01 | Jul 2, 2001 | ppd in Reliant Sinix allows local users to corrupt arbitrary files via a symlink attack in the /tmp/ppd.trace file. | |||
| CVE-2018-5391 | Hig | 0.02 | 7.5 | 0.32 | Sep 6, 2018 | The Linux kernel, versions 3.9+, is vulnerable to a denial of service attack with low rates of specially modified packets targeting IP fragment re-assembly. An attacker may cause a denial of service condition by sending specially crafted IP fragments. Various vulnerabilities in… | ||
| CVE-2011-3389 | 0.02 | — | 0.73 | Sep 6, 2011 | The SSL protocol, as used in certain configurations in Microsoft Windows and Microsoft Internet Explorer, Mozilla Firefox, Google Chrome, Opera, and other products, encrypts data by using CBC mode with chained initialization vectors, which allows man-in-the-middle attackers to… | |||
| CVE-2019-19925 | Hig | 0.01 | 7.5 | 0.07 | Dec 24, 2019 | zipfileUpdate in ext/misc/zipfile.c in SQLite 3.30.1 mishandles a NULL pathname during an update of a ZIP archive. | ||
| CVE-2019-19924 | Med | 0.01 | 5.3 | 0.08 | Dec 24, 2019 | SQLite 3.30.1 mishandles certain parser-tree rewriting, related to expr.c, vdbeaux.c, and window.c. This is caused by incorrect sqlite3WindowRewrite() error handling. | ||
| CVE-2019-19923 | Hig | 0.01 | 7.5 | 0.07 | Dec 24, 2019 | flattenSubquery in select.c in SQLite 3.30.1 mishandles certain uses of SELECT DISTINCT involving a LEFT JOIN in which the right-hand side is a view. This can cause a NULL pointer dereference (or incorrect results). | ||
| CVE-2019-19926 | Hig | 0.01 | 7.5 | 0.07 | Dec 23, 2019 | multiSelect in select.c in SQLite 3.30.1 mishandles certain errors during parsing, as demonstrated by errors from sqlite3WindowRewrite() calls. NOTE: this vulnerability exists because of an incomplete fix for CVE-2019-19880. | ||
| CVE-2019-19880 | Hig | 0.01 | 7.5 | 0.07 | Dec 18, 2019 | exprListAppendList in window.c in SQLite 3.30.1 allows attackers to trigger an invalid pointer dereference because constant integer values in ORDER BY clauses of window definitions are mishandled. | ||
| CVE-2019-19603 | Hig | 0.01 | 7.5 | 0.08 | Dec 9, 2019 | SQLite 3.30.1 mishandles certain SELECT statements with a nonexistent VIEW, leading to an application crash. | ||
| CVE-2011-3321 | 0.01 | — | 0.07 | Sep 16, 2011 | Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a… |
- risk 0.18cvss 2.7epss 0.01
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The…
- risk 0.18cvss 2.7epss 0.01
Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available…
- risk 0.18cvss 2.7epss 0.01
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A heap-based buffer overflow vulnerability was found in the `edgebox_web_app` binary. The binary will crash if supplied with a backup password longer than 255 characters. This could allow an…
- risk 0.18cvss 2.7epss 0.01
Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data.
- risk 0.18cvss 2.7epss 0.01
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the…
- risk 0.17cvss 2.6epss 0.00
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not expire the session without logout. This…
- risk 0.17cvss 2.6epss 0.00
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application improperly handles error while accessing an…
- risk 0.16cvss 2.4epss 0.00
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V10.0), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V10.0), SIPROTEC 5 6MU85…
- risk 0.16cvss 2.5epss 0.00
A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A path traversal vulnerability was found in the `deviceinfo` binary via the `mac` parameter. This could allow an authenticated attacker with access to the SSH interface on the affected device to read…
- risk 0.16cvss 2.5epss 0.00
Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors.
- risk 0.16cvss 2.5epss 0.00
Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage.
- risk 0.14cvss 3.3epss 0.00
A vulnerability was found in libxml2 up to 2.14.5. It has been declared as problematic. This vulnerability affects the function xmlParseSGMLCatalog of the component xmlcatalog. The manipulation leads to uncontrolled recursion. Attacking locally is a requirement. The exploit has…
- risk 0.14cvss 3.1epss 0.04
curl 7.7 through 7.76.1 suffers from an information disclosure when the `-t` command line option, known as `CURLOPT_TELNETOPTIONS` in libcurl, is used to send variable=content pairs to TELNET servers. Due to a flaw in the option parser for sending NEW_ENV variables, libcurl…
- CVE-2015-5374Jul 18, 2015risk 0.09cvss —epss 0.74
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03;…
- CVE-2003-0190May 12, 2003risk 0.09cvss —epss 0.77
OpenSSH-portable (OpenSSH) 3.6.1p1 and earlier with PAM support enabled immediately sends an error message when a user does not exist, which allows remote attackers to determine valid usernames via a timing attack.
- risk 0.07cvss —epss 0.00
kas is a setup tool for bitbake based projects. Starting in version 4.8 and prior to version 5.3, kas checks out and processes repositories regarding configuration includes prior to validating signatures of those repositories. This may allow to replace on original repository…
- risk 0.07cvss —epss 0.00
kas is a setup tool for bitbake based projects. Prior to version 5.3, when relying solely on a git commit ID (SHA-1 or SHA-256) to qualify if a checkout of a repository is equivalent to the state validated while adding its commit ID to a kas configuration, users may be tricked…
- CVE-2012-1803Apr 28, 2012risk 0.07cvss —epss 0.49
RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing…
- risk 0.05cvss 8.1epss 0.60
curl 7.75.0 through 7.76.1 suffers from a use-after-free vulnerability resulting in already freed memory being used when a TLS 1.3 session ticket arrives over a connection. A malicious server can use this in rare unfortunate circumstances to potentially reach remote code…
- risk 0.05cvss 9.8epss 0.58
An arbitrary file copy vulnerability in mod_copy in ProFTPD up to 1.3.5b allows for remote code execution and information disclosure without authentication, a related issue to CVE-2015-3306.
- CVE-2014-2908Apr 25, 2014risk 0.05cvss —epss 0.21
Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
- CVE-2014-5074Aug 17, 2014risk 0.04cvss —epss 0.10
Siemens SIMATIC S7-1500 CPU devices with firmware before 1.6 allow remote attackers to cause a denial of service (device restart and STOP transition) via crafted TCP packets.
- CVE-2012-5409Nov 1, 2012risk 0.04cvss —epss 0.16
AscoServer.exe in the server in Siemens SiPass integrated MP2.6 and earlier does not properly handle IOCP RPC messages received over an Ethernet network, which allows remote attackers to write data to any memory location and consequently execute arbitrary code via crafted…
- CVE-2012-2441Apr 28, 2012risk 0.04cvss —epss 0.09
RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH…
- CVE-2011-4879Feb 3, 2012risk 0.04cvss —epss 0.13
miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does…
- CVE-2011-4878Feb 3, 2012risk 0.04cvss —epss 0.12
Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime…
- CVE-2011-4877Feb 3, 2012risk 0.04cvss —epss 0.08
HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows…
- CVE-2011-4876Feb 3, 2012risk 0.04cvss —epss 0.10
Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when…
- CVE-2011-4875Feb 3, 2012risk 0.04cvss —epss 0.14
Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when…
- CVE-2011-4531Jan 8, 2012risk 0.04cvss —epss 0.09
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allows remote attackers to cause a denial of service (NULL pointer dereference and daemon crash) via crafted content in a (1) get_target_ocx_param or (2) send_target_ocx_param command.
- CVE-2011-4529Jan 8, 2012risk 0.04cvss —epss 0.07
Multiple buffer overflows in Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allow remote attackers to execute arbitrary code via a long serialid field in an _licensekey command, as demonstrated by the (1) check_licensekey or (2) read_licensekey command.
- CVE-2002-1483Apr 22, 2003risk 0.04cvss —epss 0.08
db4web_c and db4web_c.exe programs in DB4Web 3.4 and 3.6 allow remote attackers to read arbitrary files via an HTTP request whose argument is a filename of the form (1) C: (drive letter), (2) //absolute/path (double-slash), or (3) .. (dot-dot).
- risk 0.03cvss 9.8epss 0.36
xmlparse.c in Expat (aka libexpat) before 2.4.5 allows attackers to insert namespace-separator characters into namespace URIs.
- CVE-2011-4532Jan 8, 2012risk 0.03cvss —epss 0.04
Absolute path traversal vulnerability in the ALMListView.ALMListCtrl ActiveX control in almaxcx.dll in the graphical user interface in Siemens Automation License Manager (ALM) 2.0 through 5.1+SP1+Upd2 allows remote attackers to overwrite arbitrary files via the Save method.
- CVE-2011-4530Jan 8, 2012risk 0.03cvss —epss 0.04
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 does not properly copy fields obtained from clients, which allows remote attackers to cause a denial of service (exception and daemon crash) via long fields, as demonstrated by fields to the (1)…
- CVE-2009-3322Sep 23, 2009risk 0.03cvss —epss 0.03
The Siemens Gigaset SE361 WLAN router allows remote attackers to cause a denial of service (device reboot) via a flood of crafted TCP packets to port 1723.
- CVE-2008-7065Aug 25, 2009risk 0.03cvss —epss 0.04
Siemens C450 IP and C475 IP VoIP devices allow remote attackers to cause a denial of service (disconnected calls and device reboot) via a crafted SIP packet to UDP port 5060.
- CVE-2008-6916Aug 7, 2009risk 0.03cvss —epss 0.04
Siemens SpeedStream 5200 with NetPort Software 1.1 allows remote attackers to bypass authentication via an invalid Host header, possibly involving a trailing dot in the hostname.
- CVE-2009-1152Mar 26, 2009risk 0.03cvss —epss 0.05
Siemens Gigaset SE461 WiMAX router 1.5-BL024.9.6401, and possibly other versions, allows remote attackers to cause a denial of service (device restart and loss of configuration) by connecting to TCP port 53, then closing the connection.
- CVE-2004-2626Dec 31, 2004risk 0.03cvss —epss 0.03
GUI overlay vulnerability in the Java API in Siemens S55 cellular phones allows remote attackers to send unauthorized SMS messages by overlaying a confirmation message with a malicious message.
- CVE-2001-0384Jul 2, 2001risk 0.03cvss —epss 0.01
ppd in Reliant Sinix allows local users to corrupt arbitrary files via a symlink attack in the /tmp/ppd.trace file.
- risk 0.02cvss 7.5epss 0.32
The Linux kernel, versions 3.9+, is vulnerable to a denial of service attack with low rates of specially modified packets targeting IP fragment re-assembly. An attacker may cause a denial of service condition by sending specially crafted IP fragments. Various vulnerabilities in…
- CVE-2011-3389Sep 6, 2011risk 0.02cvss —epss 0.73
The SSL protocol, as used in certain configurations in Microsoft Windows and Microsoft Internet Explorer, Mozilla Firefox, Google Chrome, Opera, and other products, encrypts data by using CBC mode with chained initialization vectors, which allows man-in-the-middle attackers to…
- risk 0.01cvss 7.5epss 0.07
zipfileUpdate in ext/misc/zipfile.c in SQLite 3.30.1 mishandles a NULL pathname during an update of a ZIP archive.
- risk 0.01cvss 5.3epss 0.08
SQLite 3.30.1 mishandles certain parser-tree rewriting, related to expr.c, vdbeaux.c, and window.c. This is caused by incorrect sqlite3WindowRewrite() error handling.
- risk 0.01cvss 7.5epss 0.07
flattenSubquery in select.c in SQLite 3.30.1 mishandles certain uses of SELECT DISTINCT involving a LEFT JOIN in which the right-hand side is a view. This can cause a NULL pointer dereference (or incorrect results).
- risk 0.01cvss 7.5epss 0.07
multiSelect in select.c in SQLite 3.30.1 mishandles certain errors during parsing, as demonstrated by errors from sqlite3WindowRewrite() calls. NOTE: this vulnerability exists because of an incomplete fix for CVE-2019-19880.
- risk 0.01cvss 7.5epss 0.07
exprListAppendList in window.c in SQLite 3.30.1 allows attackers to trigger an invalid pointer dereference because constant integer values in ORDER BY clauses of window definitions are mishandled.
- risk 0.01cvss 7.5epss 0.08
SQLite 3.30.1 mishandles certain SELECT statements with a nonexistent VIEW, leading to an application crash.
- CVE-2011-3321Sep 16, 2011risk 0.01cvss —epss 0.07
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a…
Page 45 of 49