  • CVE-2013-4780Jul 18, 2013
    risk 0.00cvss epss 0.01

    core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to read arbitrary files via unspecified vectors.

  • CVE-2013-4779Jul 18, 2013
    risk 0.00cvss epss 0.01

    Cross-site scripting (XSS) vulnerability in core/handleTw.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to inject arbitrary web script or HTML via…

  • CVE-2013-4778Jul 18, 2013
    risk 0.00cvss epss 0.01

    core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to obtain sensitive server and statistics information via unspecified vectors.

  • CVE-2013-3927Jun 18, 2013
    risk 0.00cvss epss 0.00

    Unspecified vulnerability in the client library in Siemens COMOS 9.2 before 9.2.0.6.10 and 10.0 before 10.0.3.0.4 allows local users to obtain unintended write access to the database by leveraging read access.

  • CVE-2013-3959Jun 14, 2013
    risk 0.00cvss epss 0.01

    The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account…

  • CVE-2013-3958Jun 14, 2013
    risk 0.00cvss epss 0.02

    The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request.

  • CVE-2013-3957Jun 14, 2013
    risk 0.00cvss epss 0.02

    SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors.

  • CVE-2013-3634May 24, 2013
    risk 0.00cvss epss 0.01

    A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation…

  • CVE-2013-3633May 24, 2013
    risk 0.00cvss epss 0.01

    A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The user privileges…

  • CVE-2013-2780Apr 22, 2013
    risk 0.00cvss epss 0.02

    Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).

  • CVE-2013-0700Apr 22, 2013
    risk 0.00cvss epss 0.02

    Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).

  • CVE-2013-0659Apr 1, 2013
    risk 0.00cvss epss 0.06

    The debugging feature on the Siemens CP 1604 and CP 1616 interface cards with firmware before 2.5.2 allows remote attackers to execute arbitrary code via a crafted packet to UDP port 17185.

  • CVE-2013-0679Mar 21, 2013
    risk 0.00cvss epss 0.02

    Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.

  • CVE-2013-0678Mar 21, 2013
    risk 0.00cvss epss 0.02

    Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query.

  • CVE-2013-0677Mar 21, 2013
    risk 0.00cvss epss 0.02

    The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file.

  • CVE-2013-0676Mar 21, 2013
    risk 0.00cvss epss 0.02

    Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query.

  • CVE-2013-0675Mar 21, 2013
    risk 0.00cvss epss 0.01

    Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet.

  • CVE-2013-0674Mar 21, 2013
    risk 0.00cvss epss 0.03

    Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.

  • CVE-2013-0672Mar 21, 2013
    risk 0.00cvss epss 0.01

    Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data.

  • CVE-2013-0671Mar 21, 2013
    risk 0.00cvss epss 0.02

    Directory traversal vulnerability in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL.

  • CVE-2013-0670Mar 21, 2013
    risk 0.00cvss epss 0.02

    CRLF injection vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via a crafted URL.

  • CVE-2013-0669Mar 21, 2013
    risk 0.00cvss epss 0.02

    The HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to cause a denial of service (daemon crash) via a crafted HTTP request.

  • CVE-2013-0668Mar 21, 2013
    risk 0.00cvss epss 0.02

    Multiple cross-site scripting (XSS) vulnerabilities in the HMI web application in Siemens WinCC (TIA Portal) 11 allow remote attackers to inject arbitrary web script or HTML via a crafted URL.

  • CVE-2013-0667Mar 21, 2013
    risk 0.00cvss epss 0.02

    Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote attackers to inject arbitrary web script or HTML via a crafted URL.

  • CVE-2011-4515Mar 21, 2013
    risk 0.00cvss epss 0.00

    Siemens WinCC (TIA Portal) 11 uses a reversible algorithm for storing HMI web-application passwords in world-readable and world-writable files, which allows local users to obtain sensitive information by leveraging (1) physical access or (2) Sm@rt Server access.

  • CVE-2013-0656Jan 21, 2013
    risk 0.00cvss epss 0.03

    Buffer overflow in a third-party ActiveX component in Siemens SIMATIC RF-MANAGER 2008, and RF-MANAGER Basic 3.0 and earlier, allows remote attackers to execute arbitrary code via a crafted web site.

  • CVE-2012-4698Dec 23, 2012
    risk 0.00cvss epss 0.01

    Siemens RuggedCom Rugged Operating System (ROS) before 3.12, ROX I OS through 1.14.5, ROX II OS through 2.3.0, and RuggedMax OS through 4.2.1.4621.22 use hardcoded private keys for SSL and SSH communication, which makes it easier for man-in-the-middle attackers to spoof servers…

  • CVE-2012-4693Dec 18, 2012
    risk 0.00cvss epss 0.00

    Invensys Wonderware InTouch 2012 R2 and earlier and Siemens ProcessSuite use a weak encryption algorithm for data in Ps_security.ini, which makes it easier for local users to discover passwords by reading this file.

  • CVE-2012-4691Dec 18, 2012
    risk 0.00cvss epss 0.01

    Memory leak in Siemens Automation License Manager (ALM) 4.x and 5.x before 5.2 allows remote attackers to cause a denial of service (memory consumption) via crafted packets.

  • CVE-2012-3040Oct 10, 2012
    risk 0.00cvss epss 0.03

    Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.

  • CVE-2012-3037Sep 25, 2012
    risk 0.00cvss epss 0.01

    The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate.

  • CVE-2012-3034Sep 18, 2012
    risk 0.00cvss epss 0.02

    WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls.

  • CVE-2012-3032Sep 18, 2012
    risk 0.00cvss epss 0.02

    SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.

  • CVE-2012-3031Sep 18, 2012
    risk 0.00cvss epss 0.02

    Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP…

  • CVE-2012-3030Sep 18, 2012
    risk 0.00cvss epss 0.03

    WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.

  • CVE-2012-3028Sep 18, 2012
    risk 0.00cvss epss 0.01

    Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.

  • CVE-2012-3009Aug 16, 2012
    risk 0.00cvss epss 0.02

    Siemens COMOS before 9.1 Patch 413, 9.2 before Update 03 Patch 023, and 10.0 before Patch 005 allows remote authenticated users to obtain database administrative access via unspecified method calls.

  • CVE-2012-3020Aug 6, 2012
    risk 0.00cvss epss 0.01

    The Siemens Synco OZW Web Server devices OZW672.*, OZW772.*, and OZW775 with firmware before 4 have an unspecified default password, which makes it easier for remote attackers to obtain administrative access via a network session.

  • CVE-2012-3017Jul 31, 2012
    risk 0.00cvss epss 0.03

    Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets.

  • CVE-2012-3016Jul 31, 2012
    risk 0.00cvss epss 0.03

    Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets.

  • CVE-2012-3015Jul 26, 2012
    risk 0.00cvss epss 0.00

    Untrusted search path vulnerability in Siemens SIMATIC STEP7 before 5.5 SP1, as used in SIMATIC PCS7 7.1 SP3 and earlier and other products, allows local users to gain privileges via a Trojan horse DLL in a STEP7 project folder.

  • CVE-2012-3003Jun 8, 2012
    risk 0.00cvss epss 0.02

    Open redirect vulnerability in an unspecified web application in Siemens WinCC 7.0 SP3 before Update 2 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in a GET request.

  • CVE-2012-2598Jun 8, 2012
    risk 0.00cvss epss 0.02

    Buffer overflow in the DiagAgent web server in Siemens WinCC 7.0 SP3 through Update 2 allows remote attackers to cause a denial of service (agent outage) via crafted input.

  • CVE-2012-2597Jun 8, 2012
    risk 0.00cvss epss 0.02

    Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL.

  • CVE-2012-2596Jun 8, 2012
    risk 0.00cvss epss 0.01

    The XPath functionality in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 does not properly handle special characters in parameters, which allows remote authenticated users to read or modify settings via a crafted URL, related to an "XML injection" attack.

  • CVE-2012-2595Jun 8, 2012
    risk 0.00cvss epss 0.02

    Multiple cross-site scripting (XSS) vulnerabilities in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 allow remote attackers to inject arbitrary web script or HTML via vectors involving special characters in parameters.

  • CVE-2012-1802Apr 18, 2012
    risk 0.00cvss epss 0.06

    Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or…

  • CVE-2012-1800Apr 18, 2012
    risk 0.00cvss epss 0.02

    Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute…

  • CVE-2012-1799Apr 18, 2012
    risk 0.00cvss epss 0.05

    The web server on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 does not limit the rate of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack on the…

  • CVE-2011-4514Feb 3, 2012
    risk 0.00cvss epss 0.04

    The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier…

Page 40 of 41