  • CVE-2017-10724HigJun 17, 2019
    risk 0.57cvss 8.8epss 0.03

    Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope…

  • CVE-2017-10723HigJun 17, 2019
    risk 0.57cvss 8.8epss 0.03

    Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope…

  • CVE-2017-10722HigJun 17, 2019
    risk 0.51cvss 7.8epss 0.01

    Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi password. This…

  • CVE-2017-10720HigJun 17, 2019
    risk 0.51cvss 7.8epss 0.01

    Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi name. This…

  • CVE-2017-10721MedJun 17, 2019
    risk 0.42cvss 6.5epss 0.02

    Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the device has Telnet functionality enabled by default. This device acts as an Endoscope camera that allows its users to use it in various industrial systems…

  • CVE-2017-10719MedJun 17, 2019
    risk 0.42cvss 6.5epss 0.02

    Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the device has default Wi-Fi credentials that are exactly the same for every device. This device acts as an Endoscope camera that allows its users to use it…

  • CVE-2017-10718MedJun 17, 2019
    risk 0.42cvss 6.5epss 0.02