  • CVE-2017-9637MedMay 18, 2018
    risk 0.27cvss 4.1epss 0.00

    Schneider Electric Ampla MES 6.4 provides capability to interact with data from third party databases. When connectivity to those databases is configured to use a SQL user name and password, an attacker may be able to sniff details from the connection string. Schneider Electric…

  • CVE-2022-22732LowJan 30, 2023
    risk 0.25cvss 3.9epss 0.00

    A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause all remote domains to access the resources (data) supplied by the server when an attacker sends a fetch request from third-party site or malicious site. Affected Products: EcoStruxure Power…

  • CVE-2021-22799LowJan 28, 2022
    risk 0.25cvss 3.8epss 0.00

    A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0…

  • CVE-2021-22747LowMay 26, 2021
    risk 0.25cvss 3.9epss 0.00

    Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This…

  • CVE-2021-22746LowMay 26, 2021
    risk 0.25cvss 3.9epss 0.00

    Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This…

  • CVE-2021-22745LowMay 26, 2021
    risk 0.25cvss 3.9epss 0.00

    Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This…

  • CVE-2021-22744LowMay 26, 2021
    risk 0.25cvss 3.9epss 0.00

    Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This…

  • CVE-2021-22743LowMay 26, 2021
    risk 0.25cvss 3.9epss 0.00

    Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TCM 4351B installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position.

  • CVE-2021-22742LowMay 26, 2021
    risk 0.25cvss 3.9epss 0.00

    Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position.

  • CVE-2017-9635LowMay 18, 2018
    risk 0.25cvss 3.9epss 0.00

    Schneider Electric Ampla MES 6.4 provides capability to configure users and their privileges. When Ampla MES users are configured to use Simple Security, a weakness in the password hashing algorithm could be exploited to reverse the user's password. Schneider Electric recommends…

  • CVE-2018-2579LowJan 18, 2018
    risk 0.24cvss 3.7epss 0.04

    Vulnerability in the Java SE, Java SE Embedded, JRockit component of Oracle Java SE (subcomponent: Libraries). Supported versions that are affected are Java SE: 6u171, 7u161, 8u152 and 9.0.1; Java SE Embedded: 8u151; JRockit: R28.3.16. Difficult to exploit vulnerability allows…

  • CVE-2018-2790LowApr 19, 2018
    risk 0.21cvss 3.1epss 0.05

    Vulnerability in the Java SE, Java SE Embedded component of Oracle Java SE (subcomponent: Security). Supported versions that are affected are Java SE: 6u181, 7u171, 8u162 and 10; Java SE Embedded: 8u161. Difficult to exploit vulnerability allows unauthenticated attacker with…

  • CVE-2013-0662Apr 1, 2014
    risk 0.05cvss epss 0.22

    Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.

  • CVE-2013-0658Feb 15, 2013
    risk 0.05cvss epss 0.22

    Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request.

  • CVE-2013-0657Jan 21, 2013
    risk 0.05cvss epss 0.21

    Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.

  • CVE-2013-3075Apr 19, 2013
    risk 0.04cvss epss 0.11

    Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain…

  • CVE-2011-4034Dec 2, 2011
    risk 0.04cvss epss 0.13

    Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via…

  • CVE-2013-0663Apr 4, 2013
    risk 0.03cvss epss 0.06

    Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the…

  • CVE-2012-1990May 22, 2012
    risk 0.03cvss epss 0.02

    Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric Kerweb before 3.0.1 and Kerwin before 6.0.1 allow remote attackers to inject arbitrary web script or HTML via (1) the evtvariablename parameter in an evts.xml action to kw.dll, (2) unspecified search…

  • CVE-2015-7937Dec 21, 2015
    risk 0.01cvss epss 0.07

    Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data.

  • CVE-2014-0754Oct 3, 2014
    risk 0.01cvss epss 0.09

    Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec…

  • CVE-2026-14354HigJul 29, 2026
    risk 0.00cvss epss 0.00

    CWE-522 Insufficiently Protected Credentials vulnerability exists that could cause authentication bypass and unauthorized credential modification, potentially leading to compromise of managed devices, when a local privileged attacker leverages weaknesses in the handling and…

  • CVE-2026-0667CriJul 29, 2026
    risk 0.00cvss epss 0.00

    CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when communicating over the Modbus TCP protocol.

  • CVE-2015-8561Dec 15, 2015
    risk 0.00cvss epss 0.04

    The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4)…

  • CVE-2015-7918Dec 15, 2015
    risk 0.00cvss epss 0.06

    Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6)…

  • CVE-2015-3977Nov 15, 2015
    risk 0.00cvss epss 0.01

    Buffer overflow in Schneider Electric IMT25 Magnetic Flow DTM before 1.500.004 for the HART Protocol allows remote authenticated users to execute arbitrary code or cause a denial of service (memory corruption) via a crafted HART reply.

  • CVE-2015-7375Sep 25, 2015
    risk 0.00cvss epss 0.02

    Schneider Electric InduSoft Web Studio before 8.0 allows remote attackers to execute arbitrary code or cause a denial of service (unhandled runtime exception and application crash) via a crafted Indusoft Project file.

  • CVE-2015-7374Sep 25, 2015
    risk 0.00cvss epss 0.03

    The Remote Agent component in Schneider Electric InduSoft Web Studio before 8.0 allows remote attackers to execute arbitrary code via unspecified vectors, aka ZDI-CAN-2649.

  • CVE-2015-3962Sep 18, 2015
    risk 0.00cvss epss 0.01

    Schneider Electric StruxureWare Building Expert MPM before 2.15 does not use encryption for the client-server data stream, which allows remote attackers to discover credentials by sniffing the network.

  • CVE-2015-3963Aug 4, 2015
    risk 0.00cvss epss 0.04

    Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence…

  • CVE-2015-3940Aug 4, 2015
    risk 0.00cvss epss 0.00

    Untrusted search path vulnerability in Schneider Electric Wonderware System Platform before 2014 R2 Patch 01 allows local users to gain privileges via a Trojan horse DLL in an unspecified directory.

  • CVE-2015-1009Aug 1, 2015
    risk 0.00cvss epss 0.00

    Schneider Electric InduSoft Web Studio before 7.1.3.5 Patch 5 and Wonderware InTouch Machine Edition through 7.1 SP3 Patch 4 use cleartext for project-window password storage, which allows local users to obtain sensitive information by reading a file.

  • CVE-2014-8390Apr 3, 2015
    risk 0.00cvss epss 0.01

    Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file.

  • CVE-2015-0999Mar 29, 2015
    risk 0.00cvss epss 0.00

    Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file.

  • CVE-2015-0998Mar 29, 2015
    risk 0.00cvss epss 0.01

    Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network.

  • CVE-2015-0997Mar 29, 2015
    risk 0.00cvss epss 0.02

    Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force…

  • CVE-2015-0996Mar 29, 2015
    risk 0.00cvss epss 0.00

    Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to…

  • CVE-2015-0982Mar 14, 2015
    risk 0.00cvss epss 0.04

    Buffer overflow in an unspecified DLL in Schneider Electric Pelco DS-NVs before 7.8.90 allows remote attackers to execute arbitrary code via unspecified vectors.

  • CVE-2014-9206Mar 14, 2015
    risk 0.00cvss epss 0.00

    Stack-based buffer overflow in Device Type Manager (DTM) 3.1.6 and earlier for Schneider Electric Invensys SRD Control Valve Positioner devices 960 and 991 allows local users to gain privileges via a malformed DLL file.

  • CVE-2014-9200Feb 1, 2015
    risk 0.00cvss epss 0.06

    Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library…

  • CVE-2014-9198Jan 27, 2015
    risk 0.00cvss epss 0.04

    The FTP server on the Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware through 1.60 IR 04 has hardcoded credentials, which makes it easier for remote attackers to obtain access via an FTP session.

  • CVE-2014-9197Jan 27, 2015
    risk 0.00cvss epss 0.02

    The Schneider Electric ETG3000 FactoryCast HMI Gateway with firmware before 1.60 IR 04 stores rde.jar under the web root with insufficient access control, which allows remote attackers to obtain sensitive setup and configuration information via a direct request.

  • CVE-2014-9190Jan 10, 2015
    risk 0.00cvss epss 0.06

    Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.

  • CVE-2014-9188Dec 27, 2014
    risk 0.00cvss epss 0.06

    Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on…

  • CVE-2014-8514Dec 27, 2014
    risk 0.00cvss epss 0.04

    Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on…

  • CVE-2014-8513Dec 27, 2014
    risk 0.00cvss epss 0.03

    Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188. NOTE: this may be clarified later based on…

  • CVE-2014-8512Dec 27, 2014
    risk 0.00cvss epss 0.04

    Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by…

  • CVE-2014-8511Dec 27, 2014
    risk 0.00cvss epss 0.04

    Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by…

  • CVE-2014-5413Sep 18, 2014
    risk 0.00cvss epss 0.01

    Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm.

  • CVE-2014-5412Sep 18, 2014
    risk 0.00cvss epss 0.02

    Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.