VYPR
Vendor

Roche

Products
8
CVEs
8
Across products
17
Status
Private

Products

8

Recent CVEs

8
  • CVE-2026-9844HigJun 2, 2026
    risk 0.57cvss epss

    Use of default credentials vulnerability in Roche Diagnostics navify Digital Pathology (RabbitMQ Management interface modules) allows Default Usernames and Passwords. This issue affects navify Digital Pathology: from 2.0.0 before 2.4.1.

  • CVE-2025-7674HigAug 5, 2025
    risk 0.46cvss epss 0.00

    Improper Input Validation vulnerability in Roche Diagnostics navify Monitoring allows an attacker to manipulate input data, which may lead to a denial of service (DoS) due to negatively impacting the server's performance. This vulnerability has no impact on data confidentiality…

  • CVE-2024-13026MedJan 17, 2025
    risk 0.40cvss epss 0.00

    A vulnerability exists in Algo Edge up to 2.1.1 - a previously used (legacy) component of navify® Algorithm Suite. The vulnerability impacts the authentication mechanism of this component and could allow an attacker with adjacent access to the laboratory network and the Algo…

  • CVE-2018-18565Nov 20, 2018
    risk 0.00cvss epss 0.00

    An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 (Serial number below 14000) and 04.x before 04.03.00 (Serial Number above 14000), CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232…

  • CVE-2018-18563Nov 20, 2018
    risk 0.00cvss epss 0.00

    An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 (Serial number below 14000) and 04.x before 04.03.00 (Serial Number above 14000), CoaguChek Pro II before 04.03.00, CoaguChek XS Plus before 03.01.06, CoaguChek XS Pro before 03.01.06, cobas h 232…

  • CVE-2018-18564Nov 20, 2018
    risk 0.00cvss epss 0.00

    An issue was discovered in Roche Accu-Chek Inform II Instrument before 03.06.00 (Serial number below 14000) and 04.x before 04.03.00 (Serial Number above 14000), CoaguChek Pro II before 04.03.00, and cobas h 232 before 04.00.04 (Serial number above KQ0400000 or KS0400000).…

  • CVE-2018-18561Nov 20, 2018
    risk 0.00cvss epss 0.00

    An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Insecure permissions in a service interface may allow authenticated attackers in the adjacent network to execute…

  • CVE-2018-18562Nov 20, 2018
    risk 0.00cvss epss 0.00

    An issue was discovered in Roche Accu-Chek Inform II Base Unit / Base Unit Hub before 03.01.04 and CoaguChek / cobas h232 Handheld Base Unit before 03.01.04. Weak access credentials may enable attackers in the adjacent network to gain unauthorized service access via a service…