Recent CVEs

14
  • CVE-2024-47945CriOct 15, 2024
    risk 0.64cvss 9.8epss 0.01

    The devices are vulnerable to session hijacking due to insufficient entropy in its session ID generation algorithm. The session IDs are predictable, with only 32,768 possible values per user, which allows attackers to pre-generate valid session IDs, leading to unauthorized …

  • CVE-2024-47943CriOct 15, 2024
    risk 0.64cvss 9.8epss 0.01

    The firmware upgrade function in the admin web interface of the Rittal IoT Interface & CMC III Processing Unit devices checks if the patch files are signed before executing the containing run.sh script. The signing process is kind of an HMAC with a long string as key which…

  • CVE-2020-11956CriJul 14, 2020
    risk 0.64cvss 9.8epss 0.02

    An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a least privilege violation.

  • CVE-2020-11951CriJul 14, 2020
    risk 0.64cvss 9.8epss 0.02

    An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account.

  • CVE-2019-13553CriOct 25, 2019
    risk 0.64cvss 9.8epss 0.02

    Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the…

  • CVE-2020-11955HigJul 14, 2020
    risk 0.57cvss 8.8epss 0.01

    An issue was discovered on Rittal PDU-3C002DEC through 5.15.70 and CMCIII-PU-9333E0FB through 3.15.70 devices. There are insecure permissions.

  • CVE-2020-11953HigJul 14, 2020
    risk 0.57cvss 8.8epss 0.02

    An issue was discovered on Rittal PDU-3C002DEC through 5.15.40 and CMCIII-PU-9333E0FB through 3.15.70_4 devices. Attackers can execute code.

  • CVE-2019-13549HigOct 25, 2019
    risk 0.49cvss 7.5epss 0.01

    Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning…

  • CVE-2021-40222HigSep 9, 2021
    risk 0.47cvss 7.2epss 0.05

    Rittal CMC PU III Web management Version affected: V3.11.00_2. Version fixed: V3.17.10 is affected by a remote code execution vulnerablity. It is possible to introduce shell code to create a reverse shell in the PU-Hostname field of the TCP/IP Configuration dialog. Web…

  • CVE-2024-47944MedOct 15, 2024
    risk 0.44cvss 6.8epss 0.00

    The device directly executes .patch firmware upgrade files on a USB stick without any prior authentication in the admin interface. This leads to an unauthenticated code execution via the firmware upgrade function.

  • CVE-2019-19393MedOct 1, 2020
    risk 0.40cvss 6.1epss 0.01

    The Web application on Rittal CMC PU III 7030.000 V3.00 V3.11.00_2 to V3.15.70_4 devices fails to sanitize user input on the system configurations page. This allows an attacker to backdoor the device with HTML and browser-interpreted content (such as JavaScript or other…

  • CVE-2020-11952MedJul 14, 2020
    risk 0.40cvss 6.2epss 0.01

    An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. Attackers can bypass the CLI menu.

  • CVE-2021-40223MedSep 9, 2021
    risk 0.35cvss 5.4epss 0.01

    Rittal CMC PU III Web management (version V3.11.00_2) fails to sanitize user input on several parameters of the configuration (User Configuration dialog, Task Configuration dialog and set logging filter dialog). This allows an attacker to backdoor the device with HTML and…

  • CVE-2022-40633MedMar 2, 2023
    risk 0.30cvss 4.6epss 0.00

    A malicious actor can clone access cards used to open control cabinets secured with Rittal CMC III locks.