Vendor CVEs
Mitsubishielectric
All CVEs
221 total · sorted by risk| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2025-7405 | Hig | 0.47 | 7.3 | 0.00 | Sep 1, 2025 | Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to read or write the device values of the product and stop the operation of the programs, since MODBUS/TCP in the… | ||
| CVE-2026-13584 | Hig | 0.46 | — | 0.00 | Jul 30, 2026 | Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module, MELSEC iQ-L Series… | ||
| CVE-2025-5023 | Hig | 0.46 | 7.1 | 0.00 | Jul 10, 2025 | Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement… | ||
| CVE-2024-8300 | Hig | 0.46 | 7.0 | 0.00 | Nov 28, 2024 | Dead Code vulnerability in Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric ICONICS Suite Version 10.97.2,… | ||
| CVE-2024-1182 | Hig | 0.46 | 7.0 | 0.00 | Jul 4, 2024 | Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions,… | ||
| CVE-2021-20593 | Hig | 0.46 | 7.1 | 0.01 | Jul 13, 2021 | Incorrect Implementation of Authentication Algorithm in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.2.50 to Ver. 3.35, GB-50A Ver.2.50 to Ver. 3.35, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior,… | ||
| CVE-2025-8531 | Med | 0.44 | 6.8 | 0.01 | Sep 19, 2025 | Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series Q03UDVCPU, Q04UDVCPU, Q06UDVCPU, Q13UDVCPU, Q26UDVCPU, Q04UDPVCPU, Q06UDPVCPU, Q13UDPVCPU, and Q26UDPVCPU with the first 5 digits of serial No. "24082" to "27081"… | ||
| CVE-2024-1574 | Med | 0.44 | 6.7 | 0.00 | Jul 4, 2024 | Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper… | ||
| CVE-2022-40269 | Med | 0.44 | 6.8 | 0.01 | Feb 2, 2023 | Authentication Bypass by Spoofing vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model versions 01.14.000 to 01.47.000 and Mitsubishi Electric Corporation GT… | ||
| CVE-2022-29833 | Med | 0.44 | 6.8 | 0.01 | Nov 25, 2022 | Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could access to MELSEC safety CPU modules… | ||
| CVE-2022-29829 | Med | 0.44 | 6.8 | 0.01 | Nov 25, 2022 | Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U, and MT Works2… | ||
| CVE-2022-29828 | Med | 0.44 | 6.8 | 0.01 | Nov 25, 2022 | Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute… | ||
| CVE-2022-29827 | Med | 0.44 | 6.8 | 0.01 | Nov 25, 2022 | Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute… | ||
| CVE-2022-29826 | Med | 0.44 | 6.8 | 0.01 | Nov 25, 2022 | Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive… | ||
| CVE-2018-16061 | Med | 0.43 | 6.1 | 0.04 | Oct 15, 2021 | Mitsubishi Electric Europe B.V. SmartRTU devices allow XSS via the username parameter or PATH_INFO to login.php. | ||
| CVE-2025-5022 | Med | 0.42 | 6.5 | 0.01 | Jul 10, 2025 | Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit… | ||
| CVE-2025-0921 | Med | 0.42 | 6.5 | 0.00 | May 15, 2025 | Execution with Unnecessary Privileges vulnerability in multiple services of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper… | ||
| CVE-2023-6815 | Med | 0.42 | 6.5 | 0.01 | Feb 13, 2024 | Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the… | ||
| CVE-2020-5657 | Med | 0.42 | 6.5 | 0.01 | Nov 2, 2020 | Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92… | ||
| CVE-2019-14925 | Med | 0.42 | 6.5 | 0.01 | Oct 28, 2019 | An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as… | ||
| CVE-2023-2063 | Med | 0.41 | 6.3 | 0.01 | Jun 2, 2023 | Unrestricted Upload of File with Dangerous Type vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to cause information… | ||
| CVE-2022-40264 | Med | 0.41 | 6.3 | 0.00 | Dec 14, 2022 | Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ICONICS/Mitsubishi Electric GENESIS64 versions 10.96 to 10.97.2 allows an unauthenticated attacker to create, tamper with or destroy arbitrary files by getting a legitimate user… | ||
| CVE-2023-2062 | Med | 0.40 | 6.2 | 0.00 | Jun 2, 2023 | Missing Password Field Masking vulnerability in Mitsubishi Electric Corporation EtherNet/IP configuration tools SW1DNN-EIPCT-BD and SW1DNN-EIPCTFX5-BD allows a remote unauthenticated attacker to know the password for MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC… | ||
| CVE-2023-2061 | Med | 0.40 | 6.2 | 0.01 | Jun 2, 2023 | Use of Hard-coded Password vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to obtain a hard-coded password and access… | ||
| CVE-2022-40268 | Med | 0.40 | 6.1 | 0.00 | Feb 2, 2023 | Improper Restriction of Rendered UI Layers or Frames vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model versions 01.14.000 to 01.47.000 and Mitsubishi Electric… | ||
| CVE-2022-33322 | Med | 0.40 | 6.1 | 0.01 | Nov 8, 2022 | Cross-site scripting vulnerability in Mitsubishi Electric consumer electronics products (Air Conditioning, Wi-Fi Interface, Refrigerator, HEMS adapter, Remote control with Wi-Fi Interface, BATHROOM THERMO VENTILATOR, Rice cooker, Mitsubishi Electric HEMS control adapter, Energy… | ||
| CVE-2022-23127 | Med | 0.40 | 6.1 | 0.02 | Jan 21, 2022 | Cross-site Scripting vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS MobileHMI versions 10.96.2 and prior allows a remote unauthenticated attacker to gain authentication information of an MC Works64 or MobileHMI and perform any… | ||
| CVE-2021-20600 | Med | 0.39 | 5.9 | 0.02 | Oct 8, 2021 | Uncontrolled resource consumption in Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions "16" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending a large number of packets in a short time… | ||
| CVE-2019-14928 | Med | 0.39 | 5.4 | 0.44 | Oct 28, 2019 | An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script (XSS) vulnerabilities allow an attacker to inject malicious code directly into the application. An example input… | ||
| CVE-2025-2399 | Med | 0.38 | 5.9 | 0.01 | Mar 10, 2026 | Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric CNC M800V Series M800VW and M800VS, M80V Series M80V and M80VW, M800 Series M800W and M800S, M80 Series M80 and M80W, E80 Series E80, C80 Series C80, and M700V Series… | ||
| CVE-2025-7376 | Med | 0.38 | 5.9 | 0.00 | Aug 6, 2025 | Windows Shortcut Following (.LNK) vulnerability in multiple processes of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper… | ||
| CVE-2024-7316 | Med | 0.38 | 5.9 | 0.01 | Oct 17, 2024 | Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric CNC Series allows a remote unauthenticated attacker to cause Denial of Service (DoS) condition on the product by sending specially crafted packets to TCP port 683, causing an emergency stop. | ||
| CVE-2024-1573 | Med | 0.38 | 5.9 | 0.01 | Jul 4, 2024 | Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior,… | ||
| CVE-2023-6374 | Med | 0.38 | 5.9 | 0.01 | Jan 30, 2024 | Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 all serial numbers allows a remote unauthenticated attacker to bypass authentication by capture-replay attack and illegally login to the affected module. As a… | ||
| CVE-2023-3373 | Med | 0.38 | 5.9 | 0.01 | Aug 4, 2023 | Predictable Exact Value from Previous Values vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT21 model versions 01.49.000 and prior and GOT SIMPLE Series GS21 model versions 01.49.000 and prior allows a remote unauthenticated attacker to hijack data connections… | ||
| CVE-2022-40267 | Med | 0.38 | 5.9 | 0.01 | Jan 20, 2023 | Predictable Seed in Pseudo-Random Number Generator (PRNG) vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 17X**** or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC… | ||
| CVE-2022-25160 | Med | 0.38 | 5.9 | 0.01 | Apr 1, 2022 | Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric… | ||
| CVE-2022-23130 | Med | 0.38 | 5.9 | 0.01 | Jan 21, 2022 | Buffer Over-read vulnerability in Mitsubishi Electric MC Works64 versions 4.00A to 4.04E, Mitsubishi Electric GENESIS64 versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 and prior, Mitsubishi Electric ICONICS Suite versions 10.97… | ||
| CVE-2019-13555 | Med | 0.38 | 5.9 | 0.02 | Nov 13, 2019 | In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number… | ||
| CVE-2025-3784 | Med | 0.36 | 5.5 | 0.00 | Nov 27, 2025 | Cleartext Storage of Sensitive Information Vulnerability in GX Works2 all versions allows an attacker to disclose credential information stored in plaintext from project files. As a result, the attacker may be able to open project files protected by user authentication using… | ||
| CVE-2024-25087 | Med | 0.36 | 5.5 | 0.00 | Jul 2, 2024 | Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.7.0 allows local attackers to cause a Windows blue screen error. | ||
| CVE-2024-22105 | Med | 0.36 | 5.5 | 0.00 | Jul 2, 2024 | Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error. | ||
| CVE-2024-22104 | Med | 0.36 | 5.5 | 0.00 | Jul 2, 2024 | Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS). | ||
| CVE-2024-22103 | Med | 0.36 | 5.5 | 0.00 | Jul 2, 2024 | Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS). | ||
| CVE-2024-22102 | Med | 0.36 | 5.5 | 0.00 | Jul 2, 2024 | Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error. | ||
| CVE-2023-51778 | Med | 0.36 | 5.5 | 0.00 | Jul 2, 2024 | Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS). | ||
| CVE-2023-51777 | Med | 0.36 | 5.5 | 0.00 | Jul 2, 2024 | Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error. | ||
| CVE-2022-29825 | Med | 0.36 | 5.6 | 0.00 | Nov 25, 2022 | Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive… | ||
| CVE-2022-23129 | Med | 0.36 | 5.5 | 0.00 | Jan 21, 2022 | Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally.… | ||
| CVE-2021-20607 | Med | 0.36 | 5.5 | 0.01 | Dec 17, 2021 | Integer Underflow vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by… |
- risk 0.47cvss 7.3epss 0.00
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to read or write the device values of the product and stop the operation of the programs, since MODBUS/TCP in the…
- risk 0.46cvss —epss 0.00
Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module, MELSEC iQ-L Series…
- risk 0.46cvss 7.1epss 0.00
Use of Hard-coded Credentials vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement…
- risk 0.46cvss 7.0epss 0.00
Dead Code vulnerability in Mitsubishi Electric GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric Iconics Digital Solutions GENESIS64 Version 10.97.2, 10.97.2 CFR1, 10.97.2 CRF2 and 10.97.3, Mitsubishi Electric ICONICS Suite Version 10.97.2,…
- risk 0.46cvss 7.0epss 0.00
Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric MC Works64 all versions,…
- risk 0.46cvss 7.1epss 0.01
Incorrect Implementation of Authentication Algorithm in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.2.50 to Ver. 3.35, GB-50A Ver.2.50 to Ver. 3.35, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior,…
- risk 0.44cvss 6.8epss 0.01
Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series Q03UDVCPU, Q04UDVCPU, Q06UDVCPU, Q13UDVCPU, Q26UDVCPU, Q04UDPVCPU, Q06UDPVCPU, Q13UDPVCPU, and Q26UDPVCPU with the first 5 digits of serial No. "24082" to "27081"…
- risk 0.44cvss 6.7epss 0.00
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in the licensing feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper…
- risk 0.44cvss 6.8epss 0.01
Authentication Bypass by Spoofing vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model versions 01.14.000 to 01.47.000 and Mitsubishi Electric Corporation GT…
- risk 0.44cvss 6.8epss 0.01
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could access to MELSEC safety CPU modules…
- risk 0.44cvss 6.8epss 0.01
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U, and MT Works2…
- risk 0.44cvss 6.8epss 0.01
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute…
- risk 0.44cvss 6.8epss 0.01
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute…
- risk 0.44cvss 6.8epss 0.01
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive…
- risk 0.43cvss 6.1epss 0.04
Mitsubishi Electric Europe B.V. SmartRTU devices allow XSS via the username parameter or PATH_INFO to login.php.
- risk 0.42cvss 6.5epss 0.01
Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit…
- risk 0.42cvss 6.5epss 0.00
Execution with Unnecessary Privileges vulnerability in multiple services of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper…
- risk 0.42cvss 6.5epss 0.01
Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the…
- risk 0.42cvss 6.5epss 0.01
Improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series (RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92…
- risk 0.42cvss 6.5epss 0.01
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as…
- risk 0.41cvss 6.3epss 0.01
Unrestricted Upload of File with Dangerous Type vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to cause information…
- risk 0.41cvss 6.3epss 0.00
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ICONICS/Mitsubishi Electric GENESIS64 versions 10.96 to 10.97.2 allows an unauthenticated attacker to create, tamper with or destroy arbitrary files by getting a legitimate user…
- risk 0.40cvss 6.2epss 0.00
Missing Password Field Masking vulnerability in Mitsubishi Electric Corporation EtherNet/IP configuration tools SW1DNN-EIPCT-BD and SW1DNN-EIPCTFX5-BD allows a remote unauthenticated attacker to know the password for MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC…
- risk 0.40cvss 6.2epss 0.01
Use of Hard-coded Password vulnerability in FTP function on Mitsubishi Electric Corporation MELSEC iQ-R Series EtherNet/IP module RJ71EIP91 and MELSEC iQ-F Series EtherNet/IP module FX5-ENET/IP allows a remote unauthenticated attacker to obtain a hard-coded password and access…
- risk 0.40cvss 6.1epss 0.00
Improper Restriction of Rendered UI Layers or Frames vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model versions 01.14.000 to 01.47.000 and Mitsubishi Electric…
- risk 0.40cvss 6.1epss 0.01
Cross-site scripting vulnerability in Mitsubishi Electric consumer electronics products (Air Conditioning, Wi-Fi Interface, Refrigerator, HEMS adapter, Remote control with Wi-Fi Interface, BATHROOM THERMO VENTILATOR, Rice cooker, Mitsubishi Electric HEMS control adapter, Energy…
- risk 0.40cvss 6.1epss 0.02
Cross-site Scripting vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS MobileHMI versions 10.96.2 and prior allows a remote unauthenticated attacker to gain authentication information of an MC Works64 or MobileHMI and perform any…
- risk 0.39cvss 5.9epss 0.02
Uncontrolled resource consumption in Mitsubishi Electric MELSEC iQ-R series C Controller Module R12CCPU-V Firmware Versions "16" and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending a large number of packets in a short time…
- risk 0.39cvss 5.4epss 0.44
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script (XSS) vulnerabilities allow an attacker to inject malicious code directly into the application. An example input…
- risk 0.38cvss 5.9epss 0.01
Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric CNC M800V Series M800VW and M800VS, M80V Series M80V and M80VW, M800 Series M800W and M800S, M80 Series M80 and M80W, E80 Series E80, C80 Series C80, and M700V Series…
- risk 0.38cvss 5.9epss 0.00
Windows Shortcut Following (.LNK) vulnerability in multiple processes of Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper…
- risk 0.38cvss 5.9epss 0.01
Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric CNC Series allows a remote unauthenticated attacker to cause Denial of Service (DoS) condition on the product by sending specially crafted packets to TCP port 683, causing an emergency stop.
- risk 0.38cvss 5.9epss 0.01
Missing Authentication for Critical Function vulnerability in the mobile monitoring feature of Mitsubishi Electric GENESIS64 versions 10.97.2 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.2 and prior, Mitsubishi Electric Hyper Historian versions 10.97.2 and prior,…
- risk 0.38cvss 5.9epss 0.01
Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 all serial numbers allows a remote unauthenticated attacker to bypass authentication by capture-replay attack and illegally login to the affected module. As a…
- risk 0.38cvss 5.9epss 0.01
Predictable Exact Value from Previous Values vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT21 model versions 01.49.000 and prior and GOT SIMPLE Series GS21 model versions 01.49.000 and prior allows a remote unauthenticated attacker to hijack data connections…
- risk 0.38cvss 5.9epss 0.01
Predictable Seed in Pseudo-Random Number Generator (PRNG) vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 17X**** or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC…
- risk 0.38cvss 5.9epss 0.01
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions, Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions, Mitsubishi Electric MELSEC iQ-R series R00/01/02CPU all versions, Mitsubishi Electric…
- risk 0.38cvss 5.9epss 0.01
Buffer Over-read vulnerability in Mitsubishi Electric MC Works64 versions 4.00A to 4.04E, Mitsubishi Electric GENESIS64 versions 10.97 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 and prior, Mitsubishi Electric ICONICS Suite versions 10.97…
- risk 0.38cvss 5.9epss 0.02
In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number…
- risk 0.36cvss 5.5epss 0.00
Cleartext Storage of Sensitive Information Vulnerability in GX Works2 all versions allows an attacker to disclose credential information stored in plaintext from project files. As a result, the attacker may be able to open project files protected by user authentication using…
- risk 0.36cvss 5.5epss 0.00
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.7.0 allows local attackers to cause a Windows blue screen error.
- risk 0.36cvss 5.5epss 0.00
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error.
- risk 0.36cvss 5.5epss 0.00
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
- risk 0.36cvss 5.5epss 0.00
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
- risk 0.36cvss 5.5epss 0.00
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error.
- risk 0.36cvss 5.5epss 0.00
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
- risk 0.36cvss 5.5epss 0.00
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error.
- risk 0.36cvss 5.6epss 0.00
Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive…
- risk 0.36cvss 5.5epss 0.00
Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally.…
- risk 0.36cvss 5.5epss 0.01
Integer Underflow vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by…
Page 4 of 5