Electricmonk
Products
2- 7 CVEs
- 4 CVEs
Recent CVEs
11| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2023-22807 | Cri | 0.64 | 9.8 | 0.01 | Feb 15, 2023 | LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol. An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol. | ||
| CVE-2023-22804 | Cri | 0.59 | 9.1 | 0.01 | Feb 15, 2023 | LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device. | ||
| CVE-2023-0102 | Cri | 0.59 | 9.1 | 0.01 | Feb 15, 2023 | LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication for its deletion command. This could allow an attacker to delete arbitrary files. | ||
| CVE-2023-22806 | Hig | 0.49 | 7.5 | 0.00 | Feb 15, 2023 | LS ELECTRIC XBC-DN32U with operating system version 01.80 transmits sensitive information in cleartext when communicating over its XGT protocol. This could allow an attacker to gain sensitive information such as user credentials. | ||
| CVE-2023-22803 | Hig | 0.49 | 7.5 | 0.01 | Feb 15, 2023 | LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily. | ||
| CVE-2023-0103 | Hig | 0.49 | 7.5 | 0.01 | Feb 15, 2023 | If an attacker were to access memory locations of LS ELECTRIC XBC-DN32U with operating system version 01.80 that are outside of the communication buffer, the device stops operating. This could allow an attacker to cause a denial-of-service condition. | ||
| CVE-2023-22805 | Med | 0.42 | 6.5 | 0.01 | Feb 15, 2023 | LS ELECTRIC XBC-DN32U with operating system version 01.80 has improper access control to its read prohibition feature. This could allow a remote attacker to remotely set the feature to lock users out of reading data from the device. | ||
| CVE-2005-1736 | 0.00 | — | 0.01 | May 24, 2005 | PROMS 0.11 does not properly handle "certain combinations of rights," which gives more rights to users than intended. | |||
| CVE-2005-1735 | 0.00 | — | 0.01 | May 24, 2005 | Multiple cross-site scripting (XSS) vulnerabilities in PROMS before 0.11 allow remote attackers to inject arbitrary web script or HTML via unknown vectors. | |||
| CVE-2005-1737 | 0.00 | — | 0.01 | May 24, 2005 | Multiple unknown vulnerabilities in PROMS 0.11 allow "non-authorized users" to (1) view or modify the project member list or (2) modify the todos list. | |||
| CVE-2005-1734 | 0.00 | — | 0.01 | May 24, 2005 | Multiple SQL injection vulnerabilities in PROMS before 0.11 allow remote attackers to execute arbitrary SQL commands via unknown vectors. |
- risk 0.64cvss 9.8epss 0.01
LS ELECTRIC XBC-DN32U with operating system version 01.80 does not properly control access to the PLC over its internal XGT protocol. An attacker could control and tamper with the PLC by sending the packets to the PLC over its XGT protocol.
- risk 0.59cvss 9.1epss 0.01
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.
- risk 0.59cvss 9.1epss 0.01
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication for its deletion command. This could allow an attacker to delete arbitrary files.
- risk 0.49cvss 7.5epss 0.00
LS ELECTRIC XBC-DN32U with operating system version 01.80 transmits sensitive information in cleartext when communicating over its XGT protocol. This could allow an attacker to gain sensitive information such as user credentials.
- risk 0.49cvss 7.5epss 0.01
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily.
- risk 0.49cvss 7.5epss 0.01
If an attacker were to access memory locations of LS ELECTRIC XBC-DN32U with operating system version 01.80 that are outside of the communication buffer, the device stops operating. This could allow an attacker to cause a denial-of-service condition.
- risk 0.42cvss 6.5epss 0.01
LS ELECTRIC XBC-DN32U with operating system version 01.80 has improper access control to its read prohibition feature. This could allow a remote attacker to remotely set the feature to lock users out of reading data from the device.
- CVE-2005-1736May 24, 2005risk 0.00cvss —epss 0.01
PROMS 0.11 does not properly handle "certain combinations of rights," which gives more rights to users than intended.
- CVE-2005-1735May 24, 2005risk 0.00cvss —epss 0.01
Multiple cross-site scripting (XSS) vulnerabilities in PROMS before 0.11 allow remote attackers to inject arbitrary web script or HTML via unknown vectors.
- CVE-2005-1737May 24, 2005risk 0.00cvss —epss 0.01
Multiple unknown vulnerabilities in PROMS 0.11 allow "non-authorized users" to (1) view or modify the project member list or (2) modify the todos list.
- CVE-2005-1734May 24, 2005risk 0.00cvss —epss 0.01
Multiple SQL injection vulnerabilities in PROMS before 0.11 allow remote attackers to execute arbitrary SQL commands via unknown vectors.