Deltaww
Products
44- 82 CVEs
- 31 CVEs
- 25 CVEs
- 16 CVEs
- 14 CVEs
- 14 CVEs
- 14 CVEs
- 12 CVEs
- 10 CVEs
- 9 CVEs
- 8 CVEs
- 7 CVEs
- 6 CVEs
- 6 CVEs
- 4 CVEs
- 4 CVEs
- 4 CVEs
- 4 CVEs
- 3 CVEs
- 3 CVEs
- 2 CVEs
- 2 CVEs
- 2 CVEs
- 2 CVEs
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
- View all 44 products →
Recent CVEs
293| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2018-10594 | Cri | 0.72 | 9.8 | 0.69 | Jun 26, 2018 | Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network… | ||
| CVE-2023-1133 | Cri | 0.71 | 9.8 | 0.50 | Mar 27, 2023 | Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated… | ||
| CVE-2024-4548 | Cri | 0.69 | 9.8 | 0.29 | May 6, 2024 | An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateHDMWYC' message, which is split into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth… | ||
| CVE-2021-38406 | Hig | 0.69 | 7.8 | 0.78 | KEV | Sep 17, 2021 | Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker could leverage this vulnerability to execute code in the context of… | |
| CVE-2021-32955 | Cri | 0.67 | 9.8 | 0.37 | Aug 30, 2021 | Delta Electronics DIAEnergie Version 1.7.5 and prior allows unrestricted file uploads, which may allow an attacker to remotely execute code. | ||
| CVE-2022-41772 | Cri | 0.66 | 9.8 | 0.25 | Oct 31, 2022 | Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution. | ||
| CVE-2025-58321 | Cri | 0.65 | 10.0 | 0.01 | Sep 11, 2025 | Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability. | ||
| CVE-2023-47207 | Cri | 0.65 | 9.8 | 0.17 | Nov 30, 2023 | In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute code with local administrator privileges. | ||
| CVE-2022-41657 | Cri | 0.65 | 9.8 | 0.21 | Oct 31, 2022 | Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations… | ||
| CVE-2022-38142 | Cri | 0.65 | 9.8 | 0.18 | Oct 31, 2022 | Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon… | ||
| CVE-2022-43775 | Cri | 0.65 | 9.8 | 0.21 | Oct 26, 2022 | The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system. | ||
| CVE-2022-1378 | Cri | 0.65 | 9.8 | 0.19 | May 2, 2022 | Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_pgHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||
| CVE-2022-1367 | Cri | 0.65 | 9.8 | 0.19 | May 2, 2022 | Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in Handler_TCV.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||
| CVE-2022-1366 | Cri | 0.65 | 9.8 | 0.19 | May 2, 2022 | Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerChart.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands. | ||
| CVE-2022-25347 | Cri | 0.65 | 9.8 | 0.11 | Mar 29, 2022 | Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to path traversal attacks, which may allow an attacker to write arbitrary files to locations on the file system. | ||
| CVE-2021-38393 | Cri | 0.65 | 9.8 | 0.20 | Aug 30, 2021 | A Blind SQL injection vulnerability exists in the /DataHandler/HandlerAlarmGroup.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter agid before using it as… | ||
| CVE-2021-38390 | Cri | 0.65 | 9.8 | 0.20 | Aug 30, 2021 | A Blind SQL injection vulnerability exists in the /DataHandler/HandlerEnergyType.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter egyid before using it as… | ||
| CVE-2026-1952 | Cri | 0.64 | 9.8 | 0.00 | Apr 24, 2026 | Delta Electronics AS320T has denial of service via the undocumented subfunction vulnerability. | ||
| CVE-2026-1951 | Cri | 0.64 | 9.8 | 0.01 | Apr 24, 2026 | Delta Electronics AS320T has no checking of the length of the buffer with the directory name vulnerability. | ||
| CVE-2026-1950 | Cri | 0.64 | 9.8 | 0.00 | Apr 24, 2026 | Delta Electronics AS320T has No checking of the length of the buffer with the file name vulnerability. |
- risk 0.72cvss 9.8epss 0.69
Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network…
- risk 0.71cvss 9.8epss 0.50
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated…
- risk 0.69cvss 9.8epss 0.29
An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateHDMWYC' message, which is split into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth…
- risk 0.69cvss 7.8epss 0.78
Delta Electronic DOPSoft 2 (Version 2.00.07 and prior) lacks proper validation of user-supplied data when parsing specific project files. This could result in multiple out-of-bounds write instances. An attacker could leverage this vulnerability to execute code in the context of…
- risk 0.67cvss 9.8epss 0.37
Delta Electronics DIAEnergie Version 1.7.5 and prior allows unrestricted file uploads, which may allow an attacker to remotely execute code.
- risk 0.66cvss 9.8epss 0.25
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
- risk 0.65cvss 10.0epss 0.01
Delta Electronics DIALink has an Directory Traversal Authentication Bypass Vulnerability.
- risk 0.65cvss 9.8epss 0.17
In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute code with local administrator privileges.
- risk 0.65cvss 9.8epss 0.21
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations…
- risk 0.65cvss 9.8epss 0.18
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon…
- risk 0.65cvss 9.8epss 0.21
The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system.
- risk 0.65cvss 9.8epss 0.19
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_pgHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
- risk 0.65cvss 9.8epss 0.19
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in Handler_TCV.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
- risk 0.65cvss 9.8epss 0.19
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerChart.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
- risk 0.65cvss 9.8epss 0.11
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to path traversal attacks, which may allow an attacker to write arbitrary files to locations on the file system.
- risk 0.65cvss 9.8epss 0.20
A Blind SQL injection vulnerability exists in the /DataHandler/HandlerAlarmGroup.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter agid before using it as…
- risk 0.65cvss 9.8epss 0.20
A Blind SQL injection vulnerability exists in the /DataHandler/HandlerEnergyType.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter egyid before using it as…
- risk 0.64cvss 9.8epss 0.00
Delta Electronics AS320T has denial of service via the undocumented subfunction vulnerability.
- risk 0.64cvss 9.8epss 0.01
Delta Electronics AS320T has no checking of the length of the buffer with the directory name vulnerability.
- risk 0.64cvss 9.8epss 0.00
Delta Electronics AS320T has No checking of the length of the buffer with the file name vulnerability.