Codesys
Products
103- 59 CVEs
- 53 CVEs
- 52 CVEs
- 52 CVEs
- 52 CVEs
- 50 CVEs
- 49 CVEs
- 49 CVEs
- 47 CVEs
- 47 CVEs
- 43 CVEs
- 42 CVEs
- 32 CVEs
- 30 CVEs
- 30 CVEs
- 28 CVEs
- 25 CVEs
- 22 CVEs
- 20 CVEs
- 19 CVEs
- 18 CVEs
- 18 CVEs
- 17 CVEs
- 17 CVEs
- 16 CVEs
- 16 CVEs
- 16 CVEs
- 16 CVEs
- 15 CVEs
- 14 CVEs
- View all 103 products →
Recent CVEs
154| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2012-6069 | Cri | 0.65 | 10.0 | 0.03 | Jan 21, 2013 | The CoDeSys Runtime Toolkit’s file transfer functionality does not perform input validation, which allows an attacker to access files and directories outside the intended scope. This may allow an attacker to upload and download any file on the device. This could allow the … | ||
| CVE-2022-31806 | Cri | 0.64 | 9.8 | 0.01 | Jun 24, 2022 | In CODESYS V2 PLCWinNT and Runtime Toolkit 32 in versions prior to V2.4.7.57 password protection is not enabled by default and there is no information or prompt to enable password protection at login in case no password is set at the controller. | ||
| CVE-2022-31802 | Cri | 0.64 | 9.8 | 0.01 | Jun 24, 2022 | In CODESYS Gateway Server V2 for versions prior to V2.3.9.38 only a part of the the specified password is been compared to the real CODESYS Gateway password. An attacker may perform authentication by specifying a small password that matches the corresponding part of the longer… | ||
| CVE-2021-33485 | Cri | 0.64 | 9.8 | 0.01 | Aug 3, 2021 | CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow. | ||
| CVE-2021-30193 | Cri | 0.64 | 9.8 | 0.01 | May 25, 2021 | CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Write. | ||
| CVE-2021-30192 | Cri | 0.64 | 9.8 | 0.01 | May 25, 2021 | CODESYS V2 Web-Server before 1.1.9.20 has an Improperly Implemented Security Check. | ||
| CVE-2021-30190 | Cri | 0.64 | 9.8 | 0.01 | May 25, 2021 | CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control. | ||
| CVE-2021-30189 | Cri | 0.64 | 9.8 | 0.01 | May 25, 2021 | CODESYS V2 Web-Server before 1.1.9.20 has a Stack-based Buffer Overflow. | ||
| CVE-2021-30188 | Cri | 0.64 | 9.8 | 0.01 | May 25, 2021 | CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow. | ||
| CVE-2020-10245 | Cri | 0.64 | 9.8 | 0.03 | Mar 26, 2020 | CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. | ||
| CVE-2019-18858 | Cri | 0.64 | 9.8 | 0.02 | Nov 20, 2019 | CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. | ||
| CVE-2019-16265 | Cri | 0.64 | 9.8 | 0.02 | Oct 25, 2019 | CODESYS V2.3 ENI server up to V3.2.2.24 has a Buffer Overflow. | ||
| CVE-2019-13548 | Cri | 0.64 | 9.8 | 0.06 | Sep 13, 2019 | CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution. | ||
| CVE-2019-9010 | Cri | 0.64 | 9.8 | 0.02 | Aug 15, 2019 | An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are… | ||
| CVE-2018-10612 | Cri | 0.64 | 9.8 | 0.01 | Jan 29, 2019 | In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials. | ||
| CVE-2018-5440 | Cri | 0.64 | 9.8 | 0.03 | Feb 15, 2018 | A Stack-based Buffer Overflow issue was discovered in 3S-Smart CODESYS Web Server. Specifically: all Microsoft Windows (also WinCE) based CODESYS web servers running stand-alone Version 2.3, or as part of the CODESYS runtime system running prior to Version V1.1.9.19. A crafted… | ||
| CVE-2017-6027 | Cri | 0.64 | 9.8 | 0.03 | May 19, 2017 | An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A… | ||
| CVE-2017-6025 | Cri | 0.64 | 9.8 | 0.02 | May 19, 2017 | A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious… | ||
| CVE-2012-6068 | Cri | 0.64 | 9.8 | 0.05 | Jan 21, 2013 | The Runtime Toolkit in CODESYS Runtime System 2.3.x and 2.4.x does not require authentication, which allows remote attackers to execute commands via the command-line interface in the TCP listener service or transfer files via requests to the TCP listener service. | ||
| CVE-2021-34584 | Cri | 0.59 | 9.1 | 0.01 | Oct 26, 2021 | Crafted web server requests can be utilised to read partial stack or heap memory or may trigger a denial-of- service condition due to a crash in the CODESYS V2 web server prior to V1.1.9.22. |
- risk 0.65cvss 10.0epss 0.03
The CoDeSys Runtime Toolkit’s file transfer functionality does not perform input validation, which allows an attacker to access files and directories outside the intended scope. This may allow an attacker to upload and download any file on the device. This could allow the …
- risk 0.64cvss 9.8epss 0.01
In CODESYS V2 PLCWinNT and Runtime Toolkit 32 in versions prior to V2.4.7.57 password protection is not enabled by default and there is no information or prompt to enable password protection at login in case no password is set at the controller.
- risk 0.64cvss 9.8epss 0.01
In CODESYS Gateway Server V2 for versions prior to V2.3.9.38 only a part of the the specified password is been compared to the real CODESYS Gateway password. An attacker may perform authentication by specifying a small password that matches the corresponding part of the longer…
- risk 0.64cvss 9.8epss 0.01
CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow.
- risk 0.64cvss 9.8epss 0.01
CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Write.
- risk 0.64cvss 9.8epss 0.01
CODESYS V2 Web-Server before 1.1.9.20 has an Improperly Implemented Security Check.
- risk 0.64cvss 9.8epss 0.01
CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control.
- risk 0.64cvss 9.8epss 0.01
CODESYS V2 Web-Server before 1.1.9.20 has a Stack-based Buffer Overflow.
- risk 0.64cvss 9.8epss 0.01
CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow.
- risk 0.64cvss 9.8epss 0.03
CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow.
- risk 0.64cvss 9.8epss 0.02
CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow.
- risk 0.64cvss 9.8epss 0.02
CODESYS V2.3 ENI server up to V3.2.2.24 has a Buffer Overflow.
- risk 0.64cvss 9.8epss 0.06
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution.
- risk 0.64cvss 9.8epss 0.02
An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are…
- risk 0.64cvss 9.8epss 0.01
In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials.
- risk 0.64cvss 9.8epss 0.03
A Stack-based Buffer Overflow issue was discovered in 3S-Smart CODESYS Web Server. Specifically: all Microsoft Windows (also WinCE) based CODESYS web servers running stand-alone Version 2.3, or as part of the CODESYS runtime system running prior to Version V1.1.9.19. A crafted…
- risk 0.64cvss 9.8epss 0.03
An Arbitrary File Upload issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A…
- risk 0.64cvss 9.8epss 0.02
A Stack Buffer Overflow issue was discovered in 3S-Smart Software Solutions GmbH CODESYS Web Server. The following versions of CODESYS Web Server, part of the CODESYS WebVisu web browser visualization software, are affected: CODESYS Web Server Versions 2.3 and prior. A malicious…
- risk 0.64cvss 9.8epss 0.05
The Runtime Toolkit in CODESYS Runtime System 2.3.x and 2.4.x does not require authentication, which allows remote attackers to execute commands via the command-line interface in the TCP listener service or transfer files via requests to the TCP listener service.
- risk 0.59cvss 9.1epss 0.01
Crafted web server requests can be utilised to read partial stack or heap memory or may trigger a denial-of- service condition due to a crash in the CODESYS V2 web server prior to V1.1.9.22.