bridgetech
Products
6- 2 CVEs
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
Recent CVEs
4| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2025-63214 | 0.00 | — | 0.00 | Nov 19, 2025 | An issue was discovered in bridgetech VBC Server & Element Manager, firmware version 6.5.0-10 , 6.5.0-9, allowing unauthorized attackers to delete and create arbitrary accounts. | |||
| CVE-2025-63205 | 0.00 | — | 0.00 | Nov 19, 2025 | An issue was discovered in bridgetech probes VB220 IP Network Probe,VB120 Embedded IP + RF Probe, VB330 High-Capacity Probe, VB440 ST 2110 Production Analytics Probe, and NOMAD, firmware versions 6.5.0-9, allowing attackers to gain sensitive information such as administrator passwords via the /probe/core/setup/passwd endpoint. NOTE: the Supplier disagrees that 6.5.0-9 is affected, and instead reports that 5.6.0-3 and earlier are affected, and 5.6.0-4 (2020-09-21) and later are fixed. | |||
| CVE-2025-63208 | 0.00 | — | 0.00 | Nov 19, 2025 | An issue was discovered in bridgetech VB288 Objective QoE Content Extractor, firmware version 5.6.0-8, allowing attackers to gain sensitive information such as administrator passwords via the /probe/core/setup/passwd endpoint. | |||
| CVE-2025-63211 | 0.00 | — | 0.00 | Nov 19, 2025 | Stored cross-site scripting vulnerability in bridgetech VBC Server & Element Manager, firmware versions 6.5.0-9 thru 6.5.0-10, allows attackers to execute arbitrary code via the addName parameter to the /vbc/core/userSetupDoc/userSetupDoc endpoint. |
- CVE-2025-63214Nov 19, 2025risk 0.00cvss —epss 0.00
An issue was discovered in bridgetech VBC Server & Element Manager, firmware version 6.5.0-10 , 6.5.0-9, allowing unauthorized attackers to delete and create arbitrary accounts.
- CVE-2025-63205Nov 19, 2025risk 0.00cvss —epss 0.00
An issue was discovered in bridgetech probes VB220 IP Network Probe,VB120 Embedded IP + RF Probe, VB330 High-Capacity Probe, VB440 ST 2110 Production Analytics Probe, and NOMAD, firmware versions 6.5.0-9, allowing attackers to gain sensitive information such as administrator passwords via the /probe/core/setup/passwd endpoint. NOTE: the Supplier disagrees that 6.5.0-9 is affected, and instead reports that 5.6.0-3 and earlier are affected, and 5.6.0-4 (2020-09-21) and later are fixed.
- CVE-2025-63208Nov 19, 2025risk 0.00cvss —epss 0.00
An issue was discovered in bridgetech VB288 Objective QoE Content Extractor, firmware version 5.6.0-8, allowing attackers to gain sensitive information such as administrator passwords via the /probe/core/setup/passwd endpoint.
- CVE-2025-63211Nov 19, 2025risk 0.00cvss —epss 0.00
Stored cross-site scripting vulnerability in bridgetech VBC Server & Element Manager, firmware versions 6.5.0-9 thru 6.5.0-10, allows attackers to execute arbitrary code via the addName parameter to the /vbc/core/userSetupDoc/userSetupDoc endpoint.