58 total · sorted by risk| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2025-58473 | Med | 0.38 | 5.9 | 0.00 | Sep 23, 2025 | An improper resource shutdown or release vulnerability has been identified in the Click Plus C2-03CPU-2 device running firmware version 3.60. The vulnerability allows an unauthenticated attacker to perform a denial-of-service attack by exhausting all available device sessions of… | ||
| CVE-2025-57882 | Med | 0.38 | 5.9 | 0.00 | Sep 23, 2025 | An improper resource shutdown or release vulnerability has been identified in the Click Plus C2-03CPU-2 device running firmware version 3.60. The vulnerability allows an unauthenticated attacker to perform a denial-of-service attack by exhausting all available device sessions in… | ||
| CVE-2020-10919 | Med | 0.38 | 5.9 | 0.02 | Jul 23, 2020 | This vulnerability allows remote attackers to disclose sensitive information on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of… | ||
| CVE-2025-58069 | Med | 0.34 | 5.3 | 0.00 | Sep 23, 2025 | The use of a hard-coded cryptographic key was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software contains a hard-coded AES key used to protect the initial messages of a new KOPS session. | ||
| CVE-2024-25137 | Med | 0.28 | 4.3 | 0.00 | Mar 26, 2024 | In AutomationDirect C-MORE EA9 HMI there is a program that copies a buffer of a size controlled by the user into a limited sized buffer on the stack which may lead to a stack overflow. The result of this stack-based buffer overflow can lead to denial-of-service conditions. | ||
| CVE-2025-54855 | Med | 0.27 | 4.2 | 0.00 | Sep 23, 2025 | Cleartext storage of sensitive information was discovered in Click Programming Software version v3.60. The vulnerability can be exploited by a local user with access to the file system, while an administrator session is active, to steal credentials stored in clear text. | ||
| CVE-2025-60023 | Med | 0.26 | 4.0 | 0.00 | Oct 23, 2025 | A relative path traversal vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and delete arbitrary directories on the target machine. | ||
| CVE-2025-59776 | Med | 0.26 | 4.0 | 0.00 | Oct 23, 2025 | A relative path traversal vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and create arbitrary directories on the target machine. |
- risk 0.38cvss 5.9epss 0.00
An improper resource shutdown or release vulnerability has been identified in the Click Plus C2-03CPU-2 device running firmware version 3.60. The vulnerability allows an unauthenticated attacker to perform a denial-of-service attack by exhausting all available device sessions of…
- risk 0.38cvss 5.9epss 0.00
An improper resource shutdown or release vulnerability has been identified in the Click Plus C2-03CPU-2 device running firmware version 3.60. The vulnerability allows an unauthenticated attacker to perform a denial-of-service attack by exhausting all available device sessions in…
- risk 0.38cvss 5.9epss 0.02
This vulnerability allows remote attackers to disclose sensitive information on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of…
- risk 0.34cvss 5.3epss 0.00
The use of a hard-coded cryptographic key was discovered in firmware version 3.60 of the Click Plus PLC. The vulnerability relies on the fact that the software contains a hard-coded AES key used to protect the initial messages of a new KOPS session.
- risk 0.28cvss 4.3epss 0.00
In AutomationDirect C-MORE EA9 HMI there is a program that copies a buffer of a size controlled by the user into a limited sized buffer on the stack which may lead to a stack overflow. The result of this stack-based buffer overflow can lead to denial-of-service conditions.
- risk 0.27cvss 4.2epss 0.00
Cleartext storage of sensitive information was discovered in Click Programming Software version v3.60. The vulnerability can be exploited by a local user with access to the file system, while an administrator session is active, to steal credentials stored in clear text.
- risk 0.26cvss 4.0epss 0.00
A relative path traversal vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and delete arbitrary directories on the target machine.
- risk 0.26cvss 4.0epss 0.00
A relative path traversal vulnerability was discovered in Productivity Suite software version 4.4.1.19. The vulnerability allows an unauthenticated remote attacker to interact with the ProductivityService PLC simulator and create arbitrary directories on the target machine.