6| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2017-5149 | Hig | 0.58 | 8.9 | 0.01 | Feb 13, 2017 | An issue was discovered in St. Jude Medical Merlin@home, versions prior to Version 8.2.2 (RF models: EX1150; Inductive models: EX1100; and Inductive models: EX1100 with MerlinOnDemand capability). The identities of the endpoints for the communication channel between the… | ||
| CVE-2017-12712 | Hig | 0.57 | 8.8 | 0.01 | Apr 25, 2018 | The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF… | ||
| CVE-2017-12716 | Med | 0.42 | 6.5 | 0.00 | Apr 25, 2018 | Abbott Laboratories Accent and Anthem pacemakers manufactured prior to Aug 28, 2017 transmit unencrypted patient information via RF communications to programmers and home monitoring units. Additionally, the Accent and Anthem pacemakers store the optional patient information… | ||
| CVE-2017-12714 | Med | 0.42 | 6.5 | 0.01 | Apr 25, 2018 | Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base… | ||
| CVE-2023-47262 | 0.00 | — | 0.00 | Nov 14, 2023 | The startup process and device configurations of the Abbott ID NOW device, before v7.1, can be interrupted and/or modified via physical access to an internal serial port. Direct physical access is required to exploit. | |||
| CVE-2020-8997 | 0.00 | — | 0.01 | Feb 16, 2020 | Older generation Abbott FreeStyle Libre sensors allow remote attackers within close proximity to enable write access to memory via a specific NFC unlock command. NOTE: The vulnerability is not present in the FreeStyle Libre 14-day in the U.S (announced in August 2018) and… |
- risk 0.58cvss 8.9epss 0.01
An issue was discovered in St. Jude Medical Merlin@home, versions prior to Version 8.2.2 (RF models: EX1150; Inductive models: EX1100; and Inductive models: EX1100 with MerlinOnDemand capability). The identities of the endpoints for the communication channel between the…
- risk 0.57cvss 8.8epss 0.01
The authentication algorithm in Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the pacemaker via RF…
- risk 0.42cvss 6.5epss 0.00
Abbott Laboratories Accent and Anthem pacemakers manufactured prior to Aug 28, 2017 transmit unencrypted patient information via RF communications to programmers and home monitoring units. Additionally, the Accent and Anthem pacemakers store the optional patient information…
- risk 0.42cvss 6.5epss 0.01
Abbott Laboratories pacemakers manufactured prior to Aug 28, 2017 do not restrict or limit the number of correctly formatted "RF wake-up" commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce pacemaker battery life. CVSS v3 base…
- CVE-2023-47262Nov 14, 2023risk 0.00cvss —epss 0.00
The startup process and device configurations of the Abbott ID NOW device, before v7.1, can be interrupted and/or modified via physical access to an internal serial port. Direct physical access is required to exploit.
- CVE-2020-8997Feb 16, 2020risk 0.00cvss —epss 0.01
Older generation Abbott FreeStyle Libre sensors allow remote attackers within close proximity to enable write access to memory via a specific NFC unlock command. NOTE: The vulnerability is not present in the FreeStyle Libre 14-day in the U.S (announced in August 2018) and…