VYPR

Runtime

by Mendix

CVEs (3)

  • CVE-2026-6264CriApr 14, 2026
    risk 0.64cvss 9.8epss 0.00

    A critical vulnerability in the Talend JobServer and Talend Runtime allows unauthenticated remote code execution via the JMX monitoring port. The attack vector is the JMX monitoring port of the Talend JobServer. The vulnerability can be mitigated for the Talend JobServer by requiring TLS client authentication for the monitoring port; however, the patch must be applied for full mitigation. For Talend ESB Runtime, the vulnerability can be mitigated by disabling the JobServer JMX monitoring port, which is disabled by default from the R2024-07-RT patch.

  • CVE-2025-30280MedApr 8, 2025
    risk 0.34cvss 5.3epss 0.00

    A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.21.0), Mendix Runtime V10.12 (All versions < V10.12.16), Mendix Runtime V10.18 (All versions < V10.18.5), Mendix Runtime V10.6 (All versions < V10.6.22), Mendix Runtime V8 (All versions < V8.18.35), Mendix Runtime V9 (All versions < V9.24.34). Affected applications allow for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application.

  • CVE-2021-47810Jan 15, 2026
    risk 0.00cvss epss 0.00

    WibuKey Runtime 6.51 contains an unquoted service path vulnerability in the WkSvW32.exe service that allows local attackers to potentially execute arbitrary code. Attackers can exploit the unquoted path in 'C:\PROGRAM FILES (X86)\WIBUKEY\SERVER\WkSvW32.exe' to inject malicious executables and escalate privileges.