ACAP
by Axis
CVEs (7)
| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2026-0804 | Med | 0.44 | 6.7 | 0.00 | May 12, 2026 | An ACAP configuration file lacked sufficient input validation, which could allow a path traversal attack leading to potential privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application. | ||
| CVE-2026-0541 | Med | 0.44 | 6.7 | 0.00 | May 12, 2026 | ACAP applications can gain elevated privileges due to improper input validation during the installation process, potentially leading to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application. | ||
| CVE-2025-6779 | 0.00 | — | 0.00 | Nov 11, 2025 | An ACAP configuration file has improper permissions, which could allow command injection and potentially lead to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application. | |||
| CVE-2025-5452 | 0.00 | — | 0.00 | Nov 11, 2025 | A malicious ACAP application can gain access to admin-level service account credentials used by legitimate ACAP applications, leading to potential privilege escalation of the malicious ACAP application. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application. | |||
| CVE-2025-5454 | 0.00 | — | 0.00 | Nov 11, 2025 | An ACAP configuration file lacked sufficient input validation, which could allow a path traversal attack leading to potential privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application. | |||
| CVE-2025-4645 | 0.00 | — | 0.00 | Nov 11, 2025 | An ACAP configuration file lacked sufficient input validation, which could allow for arbitrary code execution. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application. | |||
| CVE-2025-3892 | 0.00 | — | 0.00 | Aug 12, 2025 | ACAP applications can be executed with elevated privileges, potentially leading to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application. |
- risk 0.44cvss 6.7epss 0.00
An ACAP configuration file lacked sufficient input validation, which could allow a path traversal attack leading to potential privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
- risk 0.44cvss 6.7epss 0.00
ACAP applications can gain elevated privileges due to improper input validation during the installation process, potentially leading to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
- CVE-2025-6779Nov 11, 2025risk 0.00cvss —epss 0.00
An ACAP configuration file has improper permissions, which could allow command injection and potentially lead to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
- CVE-2025-5452Nov 11, 2025risk 0.00cvss —epss 0.00
A malicious ACAP application can gain access to admin-level service account credentials used by legitimate ACAP applications, leading to potential privilege escalation of the malicious ACAP application. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
- CVE-2025-5454Nov 11, 2025risk 0.00cvss —epss 0.00
An ACAP configuration file lacked sufficient input validation, which could allow a path traversal attack leading to potential privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
- CVE-2025-4645Nov 11, 2025risk 0.00cvss —epss 0.00
An ACAP configuration file lacked sufficient input validation, which could allow for arbitrary code execution. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.
- CVE-2025-3892Aug 12, 2025risk 0.00cvss —epss 0.00
ACAP applications can be executed with elevated privileges, potentially leading to privilege escalation. This vulnerability can only be exploited if the Axis device is configured to allow the installation of unsigned ACAP applications, and if an attacker convinces the victim to install a malicious ACAP application.