VYPR

Micrologix 1400 Firmware

by Rockwellautomation

CVEs (36)

  • CVE-2017-12090HigApr 5, 2018
    risk 0.50cvss 7.7epss 0.04

    An exploitable denial of service vulnerability exists in the processing of snmp-set commands of the Allen Bradley Micrologix 1400 Series B FRN 21.2 and below. A specially crafted snmp-set request, when sent without associated firmware flashing snmp-set commands, can cause a…

  • CVE-2016-5645HigAug 24, 2016
    risk 0.50cvss 7.3epss 0.30

    Rockwell Automation MicroLogix 1400 PLC 1766-L32BWA, 1766-L32AWA, 1766-L32BXB, 1766-L32BWAA, 1766-L32AWAA, and 1766-L32BXBA devices have a hardcoded SNMP community, which makes it easier for remote attackers to load arbitrary firmware updates by leveraging knowledge of this…

  • CVE-2022-3166HigDec 16, 2022
    risk 0.49cvss 7.5epss 0.01

    Rockwell Automation was made aware that the webservers of the Micrologix 1100 and 1400 controllers contain a vulnerability that may lead to a denial-of-service condition. The security vulnerability could be exploited by an attacker with network access to the affected systems by…

  • CVE-2021-32926HigJun 3, 2021
    risk 0.49cvss 7.5epss 0.02

    When an authenticated password change request takes place, this vulnerability could allow the attacker to intercept the message that includes the legitimate, new password hash and replace it with an illegitimate hash. The user would no longer be able to authenticate to the…

  • CVE-2020-6988HigMar 16, 2020
    risk 0.49cvss 7.5epss 0.04

    Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, A remote, unauthenticated attacker can send a request from the RSLogix 500 software to the…

  • CVE-2020-6984HigMar 16, 2020
    risk 0.49cvss 7.5epss 0.03

    Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic function utilized to protect the password in MicroLogix is discoverable.

  • CVE-2015-6492HigOct 28, 2015
    risk 0.49cvss 7.5epss 0.04

    Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote attackers to cause a denial of service (memory corruption and device crash) via a crafted HTTP request.

  • CVE-2022-46670HigDec 16, 2022
    risk 0.46cvss 7.1epss 0.01

    Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution.  The…

  • CVE-2022-2179MedJul 20, 2022
    risk 0.42cvss 6.5epss 0.01

    The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks.

  • CVE-2019-10955MedApr 25, 2019
    risk 0.40cvss 6.1epss 0.03

    In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370…

  • CVE-2017-12093MedApr 5, 2018
    risk 0.35cvss 5.3epss 0.06

    An exploitable insufficient resource pool vulnerability exists in the session communication functionality of Allen Bradley Micrologix 1400 Series B Firmware 21.2 and before. A specially crafted stream of packets can cause a flood of the session resource pool resulting in…

  • CVE-2017-12092LowJun 4, 2018
    risk 0.24cvss 3.7epss 0.03

    An exploitable file write vulnerability exists in the memory module functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a file write resulting in a new program being written to the memory module. An attacker can send…

  • CVE-2020-6980LowMar 16, 2020
    risk 0.21cvss 3.3epss 0.00

    Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker…

  • CVE-2015-6491Oct 28, 2015
    risk 0.00cvss epss 0.02

    Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote authenticated users to insert the content of an arbitrary file into a FRAME element via unspecified vectors.

  • CVE-2015-6488Oct 28, 2015
    risk 0.00cvss epss 0.03

    Cross-site scripting (XSS) vulnerability in the web server on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

  • CVE-2015-6486Oct 28, 2015
    risk 0.00cvss epss 0.04

    SQL injection vulnerability on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allows remote authenticated users to execute arbitrary SQL commands via unspecified vectors.

Page 2 of 2