V Series Appliances
Sign in to watchby Websense
CVEs (9)
| CVE | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|
| CVE-2015-2746 | 0.05 | — | 0.24 | Mar 26, 2015 | The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command. | ||
| CVE-2015-2771 | 0.00 | — | 0.00 | Mar 27, 2015 | The Mail Server in Websense TRITON AP-EMAIL and V-Series appliances before 8.0.0 uses plaintext credentials, which allows remote attackers to obtain sensitive information via unspecified vectors. | ||
| CVE-2015-2770 | 0.00 | — | 0.00 | Mar 27, 2015 | Cross-site request forgery (CSRF) vulnerability in the command line page in Websense TRITON V-Series appliances before 8.0.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors. | ||
| CVE-2015-2768 | 0.00 | — | 0.00 | Mar 27, 2015 | Cross-site scripting (XSS) vulnerability in Websense TRITON AP-EMAIL before 8.0.0 and V-Series 7.7 appliances allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | ||
| CVE-2014-9712 | 0.00 | — | 0.00 | Mar 27, 2015 | Websense TRITON V-Series appliances before 7.8.3 Hotfix 03 and 7.8.4 before Hotfix 01 allow remote administrators to read arbitrary files and obtain passwords via a crafted path. | ||
| CVE-2015-2748 | 0.00 | — | 0.00 | Mar 26, 2015 | Websense TRITON AP-WEB before 8.0.0 does not properly restrict access to files in explorer_wse/, which allows remote attackers to obtain sensitive information via a direct request to a (1) Web Security incident report or the (2) Explorer configuration (websense.ini) file. | ||
| CVE-2015-2747 | 0.00 | — | 0.00 | Mar 26, 2015 | Multiple cross-site scripting (XSS) vulnerabilities in the data loss prevention (DLP) incident Forensics Preview in Websense Triton 7.8.3 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via a crafted (1) email or (2) HTTP request, which triggers a DLP Policy. | ||
| CVE-2015-2703 | 0.00 | — | 0.01 | Mar 25, 2015 | Multiple cross-site scripting (XSS) vulnerabilities in Websense TRITON AP-WEB before 8.0.0 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via the (1) ws-userip in the ws-encdata parameter to cve-bin/moreBlockInfo.cgi in the Data Security block page or (2) admin_msg parameter to configure/ssl_ui/eva-config/client-cert-import_wsoem.html in the Content Gateway, which is not properly handled in an error message. | ||
| CVE-2015-2702 | 0.00 | — | 0.00 | Mar 25, 2015 | Cross-site scripting (XSS) vulnerability in the Message Log in the Email Security Gateway in Websense TRITON AP-EMAIL before 8.0.0 and V-Series 7.7 appliances allows remote attackers to inject arbitrary web script or HTML via the sender address in an email. |