CVEs (8)

  • CVE-2025-40759HigAug 12, 2025
    risk 0.51cvss 7.8epss 0.00

    A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17…

  • CVE-2017-12741HigDec 26, 2017
    risk 0.49cvss 7.5epss 0.03

    Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.

  • CVE-2017-2681MedMay 11, 2017
    risk 0.42cvss 6.5epss 0.01

    Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.

  • CVE-2017-2680MedMay 11, 2017
    risk 0.42cvss 6.5epss 0.01

    Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.

  • CVE-2025-40584MedAug 12, 2025
    risk 0.36cvss 5.5epss 0.00

    A vulnerability has been identified in SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions < V5.7 SP1 HF1), SIMOTION SCOUT V5.4 (All versions), SIMOTION SCOUT…

  • CVE-2019-13946Feb 11, 2020
    risk 0.00cvss epss 0.01

    Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that…

  • CVE-2019-10923Oct 10, 2019
    risk 0.00cvss epss 0.01

    An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.

  • CVE-2015-1594Mar 7, 2015
    risk 0.00cvss epss 0.00

    Untrusted search path vulnerability in Siemens SIMATIC ProSave before 13 SP1; SIMATIC CFC before 8.0 SP4 Upd9 and 8.1 before Upd1; SIMATIC STEP 7 before 5.5 SP1 HF2, 5.5 SP2 before HF7, 5.5 SP3, and 5.5 SP4 before HF4; SIMOTION Scout before 4.4; and STARTER before 4.4 HF3 allows…