VYPR

Ac7 Firmware

by Tenda

CVEs (74)

  • CVE-2023-37717CriJul 14, 2023
    risk 0.64cvss 9.8epss 0.01

    Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.

  • CVE-2023-37716CriJul 14, 2023
    risk 0.64cvss 9.8epss 0.01

    Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.

  • CVE-2023-37714CriJul 14, 2023
    risk 0.64cvss 9.8epss 0.01

    Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.

  • CVE-2018-18729CriOct 29, 2018
    risk 0.64cvss 9.8epss 0.01

    An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the…

  • CVE-2025-8017HigJul 22, 2025
    risk 0.58cvss 8.8epss 0.09

    A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It…

  • CVE-2025-5861HigJun 9, 2025
    risk 0.58cvss 8.8epss 0.05

    A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be initiated remotely.…

  • CVE-2025-3346HigApr 7, 2025
    risk 0.58cvss 8.8epss 0.07

    A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to buffer overflow.…

  • CVE-2026-4974HigMar 27, 2026
    risk 0.57cvss 8.8epss 0.01

    A flaw has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg of the component POST Request Handler. Executing a manipulation of the argument Time can lead to stack-based buffer overflow. It is possible to…

  • CVE-2025-11586HigOct 10, 2025
    risk 0.57cvss 8.8epss 0.01

    A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been…

  • CVE-2025-11528HigOct 9, 2025
    risk 0.57cvss 8.8epss 0.01

    A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly…

  • CVE-2025-11527HigOct 9, 2025
    risk 0.57cvss 8.8epss 0.01

    A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The…

  • CVE-2025-11526HigOct 9, 2025
    risk 0.57cvss 8.8epss 0.01

    A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit…

  • CVE-2025-11525HigOct 9, 2025
    risk 0.57cvss 8.8epss 0.01

    A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the…

  • CVE-2025-11524HigOct 9, 2025
    risk 0.57cvss 8.8epss 0.01

    A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be…

  • CVE-2025-9023HigAug 15, 2025
    risk 0.57cvss 8.8epss 0.01

    A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has…

  • CVE-2025-5862HigJun 9, 2025
    risk 0.57cvss 8.8epss 0.01

    A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The…

  • CVE-2025-4810HigMay 16, 2025
    risk 0.57cvss 8.8epss 0.01

    A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The…

  • CVE-2025-4809HigMay 16, 2025
    risk 0.57cvss 8.8epss 0.01

    A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch…

  • CVE-2025-1851HigMar 3, 2025
    risk 0.57cvss 8.8epss 0.01

    A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to…

  • CVE-2024-48826HigOct 28, 2024
    risk 0.57cvss 8.8epss 0.02

    Tenda AC7 v.15.03.06.44 ate_iwpriv_set has pre-authentication command injection allowing remote attackers to execute arbitrary code.