VYPR

Scalance S615 Firmware

by Siemens Foundation

CVEs (17)

  • CVE-2017-14491CriOct 4, 2017
    risk 0.73cvss 9.8epss 0.85

    Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execute arbitrary code via a crafted DNS response.

  • CVE-2022-36323CriAug 10, 2022
    risk 0.59cvss 9.1epss 0.01

    Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.

  • CVE-2021-25667HigMar 15, 2021
    risk 0.57cvss 8.8epss 0.01

    A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions…

  • CVE-2017-12736HigDec 26, 2017
    risk 0.57cvss 8.8epss 0.01

    After initial configuration, the Ruggedcom Discovery Protocol (RCDP) is still able to write to the device under certain conditions. This could allow an attacker located in the adjacent network of the targeted device to perform unauthorized administrative actions.

  • CVE-2022-36324HigAug 10, 2022
    risk 0.49cvss 7.5epss 0.01

    Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.

  • CVE-2022-36325MedAug 10, 2022
    risk 0.44cvss 6.8epss 0.01

    Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.

  • CVE-2017-2681MedMay 11, 2017
    risk 0.42cvss 6.5epss 0.01

    Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.

  • CVE-2017-2680MedMay 11, 2017
    risk 0.42cvss 6.5epss 0.01

    Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.

  • CVE-2016-7090MedSep 29, 2016
    risk 0.26cvss 4.0epss 0.02

    The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an…

  • CVE-2023-44321Nov 14, 2023
    risk 0.00cvss epss 0.01

    Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available…

  • CVE-2023-44318Nov 14, 2023
    risk 0.00cvss epss 0.01

    Affected devices use a hardcoded key to obfuscate the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that obtains a configuration backup to extract configuration…

  • CVE-2022-46143Dec 13, 2022
    risk 0.00cvss epss 0.01

    Affected devices do not check the TFTP blocksize correctly. This could allow an authenticated attacker to read from an uninitialized buffer that potentially contains previously allocated data.

  • CVE-2022-46142Dec 13, 2022
    risk 0.00cvss epss 0.00

    Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords.

  • CVE-2022-46140Dec 13, 2022
    risk 0.00cvss epss 0.00

    Affected devices use a weak encryption scheme to encrypt the debug zip file. This could allow an authenticated attacker to decrypt the contents of the file and retrieve debug information about the system.

  • CVE-2020-28400Jul 13, 2021
    risk 0.00cvss epss 0.02

    Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.

  • CVE-2021-25676Mar 15, 2021
    risk 0.00cvss epss 0.01

    A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions.…

  • CVE-2019-6569Mar 26, 2019
    risk 0.00cvss epss 0.01

    The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their…