VYPR

VigorSwitch

by Draytek

CVEs (29)

  • CVE-2026-71921CriAug 24, 2026
    risk 0.64cvss 9.8epss

    Multiple DrayTek VigorSwitch models contain a pre-authentication command injection vulnerability in the setget.cgi interface. The vulnerability is caused by insufficient filtering of the pass field before command execution. A remote attacker can trigger this vulnerability via…

  • CVE-2026-71933CriAug 24, 2026
    risk 0.59cvss 9.1epss

    Multiple DrayTek VigorSwitch models contain unauthorized operation vulnerabilities in multiple syslog functions. The vulnerability is caused by missing authorization checks. A remote attacker can trigger these vulnerabilities via crafted requests to modify configuration, restart…

  • CVE-2026-71922HigAug 24, 2026
    risk 0.49cvss 7.5epss

    Multiple DrayTek VigorSwitch models contain a pre-authentication null pointer dereference vulnerability in the setget.cgi interface. The vulnerability is caused by missing validation when the pass field is absent. A remote attacker can trigger this vulnerability via a crafted…

  • CVE-2026-71943HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevNet function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via…

  • CVE-2026-71942HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the mail_mailalert function. The vulnerability is caused by concatenating multiple smtpReceiver email addresses into a fixed-size buffer without checking the remaining buffer size. A remote attacker…

  • CVE-2026-71941HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the diag_logmail function. The vulnerability is caused by concatenating multiple smtpReceiver email addresses into a fixed-size buffer without checking the remaining buffer size. A remote attacker can…

  • CVE-2026-71940HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the acl_general_setup Edit ACE function. The vulnerability is caused by copying the name field into a fixed-size buffer without length validation. A remote attacker can trigger this vulnerability via…

  • CVE-2026-71939HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the acl_general_setup Add ACE function. The vulnerability is caused by copying the name field into a fixed-size buffer without length validation. A remote attacker can trigger this vulnerability via…

  • CVE-2026-71938HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the switch_lan_gvrp function. The vulnerability is caused by unsafe copying of the portList field into an undersized buffer. A remote attacker can trigger this vulnerability via crafted input, causing…

  • CVE-2026-71937HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the poe_schedule_profile function. The vulnerability is caused by repeated concatenation of the start_date, start_time, duration_time, how_often, weekdays, monthly_date, and cycle_duration fields into…

  • CVE-2026-71936HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the sysreboot function. The vulnerability is caused by unsafe concatenation of split valueN data into a fixed-size buffer. A remote attacker can trigger this vulnerability via crafted input, causing a…

  • CVE-2026-71935HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the webBackupAction function. The vulnerability is caused by repeated string concatenation of the pathN, valueN, key, and option fields into fixed-size stack buffers without total length checks. A…

  • CVE-2026-71934HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the pingtrace function. The vulnerability is caused by missing length checks when the host, count, and interval fields are concatenated into a fixed-size buffer. A remote attacker can trigger this…

  • CVE-2026-71931HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the tftp_upgrade function. The vulnerability is caused by insufficient filtering before the filename field is concatenated into a command. A remote attacker can trigger this vulnerability via…

  • CVE-2026-71930HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setTime function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via crafted…

  • CVE-2026-71929HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevProto function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via…

  • CVE-2026-71928HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the fdftDevice function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via…

  • CVE-2026-71927HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the rebDevice function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via…

  • CVE-2026-71926HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevice function. The vulnerability is caused by insufficient sanitization of the username, password, and location fields before command execution. A remote attacker can trigger this…

  • CVE-2026-71925HigAug 24, 2026
    risk 0.47cvss 7.2epss

    Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getDetail function. The vulnerability is caused by insufficient filtering of the username and password fields before command execution. A remote attacker can trigger this vulnerability via…