Opc
by Softx
CVEs (17)
| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2022-2336 | Cri | 0.64 | 9.8 | 0.01 | Aug 17, 2022 | Softing Secure Integration Server, edgeConnector, and edgeAggregator software ships with the default administrator credentials as `admin` and password as `admin`. This allows Softing to log in to the server directly to perform administrative functions. Upon installation or upon… | ||
| CVE-2020-14524 | Cri | 0.64 | 9.8 | 0.03 | Aug 25, 2020 | Softing Industrial Automation all versions prior to the latest build of version 4.47.0, The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute arbitrary code. | ||
| CVE-2022-2334 | Hig | 0.51 | 7.2 | 0.10 | Aug 17, 2022 | The application searches for a library dll that is not found. If an attacker can place a dll with this name, then the attacker can leverage it to execute arbitrary code on the targeted Softing Secure Integration Server V1.22. | ||
| CVE-2022-1373 | Hig | 0.51 | 7.2 | 0.11 | Aug 17, 2022 | The “restore configuration” feature of Softing Secure Integration Server V1.22 is vulnerable to a directory traversal vulnerability when processing zip files. An attacker can craft a zip file to load an arbitrary dll and execute code. Using the "restore configuration"… | ||
| CVE-2023-41151 | Hig | 0.49 | 7.5 | 0.01 | Dec 14, 2023 | An uncaught exception issue discovered in Softing OPC UA C++ SDK before 6.30 for Windows operating system may cause the application to crash when the server wants to send an error packet, while socket is blocked on writing. | ||
| CVE-2023-37572 | Hig | 0.49 | 7.5 | 0.01 | Dec 5, 2023 | Softing OPC Suite version 5.25 and before has Incorrect Access Control, allows attackers to obtain sensitive information via weak permissions in OSF_discovery service. The service executable could be changed or the service could be deleted. | ||
| CVE-2022-39823 | Hig | 0.49 | 7.5 | 0.01 | Oct 20, 2022 | An issue was discovered in Softing OPC UA C++ SDK 5.66 through 6.x before 6.10. An OPC/UA browse request exceeding the server limit on continuation points may cause a use-after-free error | ||
| CVE-2022-37453 | Hig | 0.49 | 7.5 | 0.01 | Oct 20, 2022 | An issue was discovered in Softing OPC UA C++ SDK before 6.10. A buffer overflow or an excess allocation happens due to unchecked array and matrix bounds in structure data types. | ||
| CVE-2022-2547 | Hig | 0.49 | 7.5 | 0.01 | Aug 17, 2022 | A crafted HTTP packet without a content-type header can create a denial-of-service condition in Softing Secure Integration Server V1.22. | ||
| CVE-2022-2337 | Hig | 0.49 | 7.5 | 0.01 | Aug 17, 2022 | A crafted HTTP packet with a missing HTTP URI can create a denial-of-service condition in Softing Secure Integration Server V1.22. | ||
| CVE-2022-2335 | Hig | 0.49 | 7.5 | 0.01 | Aug 17, 2022 | A crafted HTTP packet with a -1 content-length header can create a denial-of-service condition in Softing Secure Integration Server V1.22. | ||
| CVE-2022-1748 | Hig | 0.49 | 7.5 | 0.01 | Aug 17, 2022 | Softing OPC UA C++ Server SDK, Secure Integration Server, edgeConnector, edgeAggregator, OPC Suite, and uaGate are affected by a NULL pointer dereference vulnerability. | ||
| CVE-2022-1069 | Hig | 0.49 | 7.5 | 0.01 | Aug 17, 2022 | A crafted HTTP packet with a large content-length header can create a denial-of-service condition in Softing Secure Integration Server V1.22. | ||
| CVE-2021-40873 | Hig | 0.49 | 7.5 | 0.01 | Nov 10, 2021 | An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66, and uaToolkit Embedded before 1.40. Remote attackers to cause a denial of service (DoS) by sending crafted messages to a client or server. The server process may crash unexpectedly because of a… | ||
| CVE-2021-40871 | Hig | 0.49 | 7.5 | 0.01 | Nov 10, 2021 | An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66. Remote attackers to cause a denial of service (DoS) by sending crafted messages to a OPC/UA client. The client process may crash unexpectedly because of a wrong type cast, and must be restarted. | ||
| CVE-2020-14522 | Hig | 0.49 | 7.5 | 0.01 | Aug 25, 2020 | Softing Industrial Automation all versions prior to the latest build of version 4.47.0, The affected product is vulnerable to uncontrolled resource consumption, which may allow an attacker to cause a denial-of-service condition. | ||
| CVE-2022-2338 | Med | 0.37 | 5.7 | 0.00 | Aug 17, 2022 | Softing Secure Integration Server V1.22 is vulnerable to authentication bypass via a machine-in-the-middle attack. The default the administration interface is accessible via plaintext HTTP protocol, facilitating the attack. The HTTP request may contain the session cookie in the… |
- risk 0.64cvss 9.8epss 0.01
Softing Secure Integration Server, edgeConnector, and edgeAggregator software ships with the default administrator credentials as `admin` and password as `admin`. This allows Softing to log in to the server directly to perform administrative functions. Upon installation or upon…
- risk 0.64cvss 9.8epss 0.03
Softing Industrial Automation all versions prior to the latest build of version 4.47.0, The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute arbitrary code.
- risk 0.51cvss 7.2epss 0.10
The application searches for a library dll that is not found. If an attacker can place a dll with this name, then the attacker can leverage it to execute arbitrary code on the targeted Softing Secure Integration Server V1.22.
- risk 0.51cvss 7.2epss 0.11
The “restore configuration” feature of Softing Secure Integration Server V1.22 is vulnerable to a directory traversal vulnerability when processing zip files. An attacker can craft a zip file to load an arbitrary dll and execute code. Using the "restore configuration"…
- risk 0.49cvss 7.5epss 0.01
An uncaught exception issue discovered in Softing OPC UA C++ SDK before 6.30 for Windows operating system may cause the application to crash when the server wants to send an error packet, while socket is blocked on writing.
- risk 0.49cvss 7.5epss 0.01
Softing OPC Suite version 5.25 and before has Incorrect Access Control, allows attackers to obtain sensitive information via weak permissions in OSF_discovery service. The service executable could be changed or the service could be deleted.
- risk 0.49cvss 7.5epss 0.01
An issue was discovered in Softing OPC UA C++ SDK 5.66 through 6.x before 6.10. An OPC/UA browse request exceeding the server limit on continuation points may cause a use-after-free error
- risk 0.49cvss 7.5epss 0.01
An issue was discovered in Softing OPC UA C++ SDK before 6.10. A buffer overflow or an excess allocation happens due to unchecked array and matrix bounds in structure data types.
- risk 0.49cvss 7.5epss 0.01
A crafted HTTP packet without a content-type header can create a denial-of-service condition in Softing Secure Integration Server V1.22.
- risk 0.49cvss 7.5epss 0.01
A crafted HTTP packet with a missing HTTP URI can create a denial-of-service condition in Softing Secure Integration Server V1.22.
- risk 0.49cvss 7.5epss 0.01
A crafted HTTP packet with a -1 content-length header can create a denial-of-service condition in Softing Secure Integration Server V1.22.
- risk 0.49cvss 7.5epss 0.01
Softing OPC UA C++ Server SDK, Secure Integration Server, edgeConnector, edgeAggregator, OPC Suite, and uaGate are affected by a NULL pointer dereference vulnerability.
- risk 0.49cvss 7.5epss 0.01
A crafted HTTP packet with a large content-length header can create a denial-of-service condition in Softing Secure Integration Server V1.22.
- risk 0.49cvss 7.5epss 0.01
An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66, and uaToolkit Embedded before 1.40. Remote attackers to cause a denial of service (DoS) by sending crafted messages to a client or server. The server process may crash unexpectedly because of a…
- risk 0.49cvss 7.5epss 0.01
An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66. Remote attackers to cause a denial of service (DoS) by sending crafted messages to a OPC/UA client. The client process may crash unexpectedly because of a wrong type cast, and must be restarted.
- risk 0.49cvss 7.5epss 0.01
Softing Industrial Automation all versions prior to the latest build of version 4.47.0, The affected product is vulnerable to uncontrolled resource consumption, which may allow an attacker to cause a denial-of-service condition.
- risk 0.37cvss 5.7epss 0.00
Softing Secure Integration Server V1.22 is vulnerable to authentication bypass via a machine-in-the-middle attack. The default the administration interface is accessible via plaintext HTTP protocol, facilitating the attack. The HTTP request may contain the session cookie in the…