Armorstart Lt Firmware
CVEs (9)
| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2025-9466 | Hig | 0.49 | 7.5 | 0.01 | Jan 20, 2026 | A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP and CIP grammar tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds. | ||
| CVE-2025-9465 | Hig | 0.49 | 7.5 | 0.00 | Jan 20, 2026 | A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive grammar tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds. | ||
| CVE-2025-9464 | Hig | 0.49 | 7.5 | 0.00 | Jan 20, 2026 | A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. This vulnerability is triggered during fuzzing of multiple CIP classes, which causes the CIP port to become unresponsive. | ||
| CVE-2025-9283 | Hig | 0.49 | 7.5 | 0.01 | Jan 20, 2026 | A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP Step Limits Storms tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds. | ||
| CVE-2025-9282 | Hig | 0.49 | 7.5 | 0.01 | Jan 20, 2026 | A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive limited storm tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds. | ||
| CVE-2025-9281 | Hig | 0.49 | 7.5 | 0.01 | Jan 20, 2026 | A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive step limit storm tests, the device reboots | ||
| CVE-2025-9280 | Hig | 0.49 | 7.5 | 0.00 | Jan 20, 2026 | A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. Fuzzing performed using Defensics causes the device to become unresponsive, requiring a reboot. | ||
| CVE-2025-9279 | Hig | 0.49 | 7.5 | 0.01 | Jan 20, 2026 | A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP Step Limit Storm tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds. | ||
| CVE-2025-9278 | Hig | 0.49 | 7.5 | 0.00 | Jan 20, 2026 | A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. After running a Burp Suite active scan, the device loses ICMP connectivity, causing the web application to become inaccessible. |
- risk 0.49cvss 7.5epss 0.01
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP and CIP grammar tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds.
- risk 0.49cvss 7.5epss 0.00
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive grammar tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds.
- risk 0.49cvss 7.5epss 0.00
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. This vulnerability is triggered during fuzzing of multiple CIP classes, which causes the CIP port to become unresponsive.
- risk 0.49cvss 7.5epss 0.01
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP Step Limits Storms tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds.
- risk 0.49cvss 7.5epss 0.01
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive limited storm tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds.
- risk 0.49cvss 7.5epss 0.01
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles Comprehensive step limit storm tests, the device reboots
- risk 0.49cvss 7.5epss 0.00
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. Fuzzing performed using Defensics causes the device to become unresponsive, requiring a reboot.
- risk 0.49cvss 7.5epss 0.01
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. During execution of the Achilles EtherNet/IP Step Limit Storm tests, the device reboots unexpectedly, causing the Link State Monitor to go down for several seconds.
- risk 0.49cvss 7.5epss 0.00
A security issue exists within ArmorStart® LT that can result in a denial-of-service condition. After running a Burp Suite active scan, the device loses ICMP connectivity, causing the web application to become inaccessible.