System 800xA
by Abb
CVEs (4)
| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2020-8484 | Hig | 0.51 | 7.8 | 0.00 | Apr 29, 2020 | Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash. | ||
| CVE-2024-10334 | Hig | 0.47 | 7.3 | 0.00 | Feb 10, 2025 | A vulnerability exists in the VideONet product included in the listed System 800xA versions, where VideONet is used. An attacker who successfully exploited the vulnerability could, in the worst case scenario, stop or manipulate the video feed. This issue affects System 800xA:… | ||
| CVE-2020-8472 | Med | 0.36 | 5.5 | 0.00 | Apr 29, 2020 | Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to… | ||
| CVE-2020-8478 | Med | 0.34 | 5.3 | 0.00 | Apr 29, 2020 | Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data,… |
- risk 0.51cvss 7.8epss 0.00
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
- risk 0.47cvss 7.3epss 0.00
A vulnerability exists in the VideONet product included in the listed System 800xA versions, where VideONet is used. An attacker who successfully exploited the vulnerability could, in the worst case scenario, stop or manipulate the video feed. This issue affects System 800xA:…
- risk 0.36cvss 5.5epss 0.00
Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to…
- risk 0.34cvss 5.3epss 0.00
Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data,…