VYPR

Real-Time Automation Controller Web Interface

by Schweitzer Engineering Laboratories, Inc.

CVEs (12)

  • CVE-2023-31149CriMay 10, 2023
    risk 0.59cvss 9.1epss 0.01

    An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to execute arbitrary code. See SEL Service Bulletin dated 2022-11-15 for more details. …

  • CVE-2023-31148CriMay 10, 2023
    risk 0.59cvss 9.1epss 0.01

    An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to execute arbitrary code. See SEL Service Bulletin dated 2022-11-15 for more details.

  • CVE-2023-31151MedMay 10, 2023
    risk 0.31cvss 4.7epss 0.00

    An Improper Certificate Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote unauthenticated attacker to conduct a man-in-the-middle (MitM) attack. See SEL Service Bulletin dated…

  • CVE-2023-31165MedMay 10, 2023
    risk 0.28cvss 4.3epss 0.00

    An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…

  • CVE-2023-31163MedMay 10, 2023
    risk 0.28cvss 4.3epss 0.00

    An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…

  • CVE-2023-31158MedMay 10, 2023
    risk 0.28cvss 4.3epss 0.00

    An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…

  • CVE-2023-31157MedMay 10, 2023
    risk 0.28cvss 4.3epss 0.00

    An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…

  • CVE-2023-31155MedMay 10, 2023
    risk 0.28cvss 4.3epss 0.00

    An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…

  • CVE-2023-31154MedMay 10, 2023
    risk 0.28cvss 4.3epss 0.00

    An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…

  • CVE-2023-31153MedMay 10, 2023
    risk 0.28cvss 4.3epss 0.00

    An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary…

  • CVE-2023-31166MedMay 10, 2023
    risk 0.27cvss 4.1epss 0.01

    An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of…

  • CVE-2023-31152MedMay 10, 2023
    risk 0.26cvss 4.0epss 0.00

    An Authentication Bypass Using an Alternate Path or Channel vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface allows Authentication Bypass. See SEL Service Bulletin dated 2022-11-15 for more details.