Medfusion 4000 Wireless Syringe Infusion Pump

by Smiths Medical

CVEs (8)

  • CVE-2017-12718HigFeb 15, 2018
    risk 0.57cvss 8.1epss 0.13

    A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote…

  • CVE-2017-12724HigFeb 15, 2018
    risk 0.53cvss 8.1epss 0.01

    A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the…

  • CVE-2017-12720HigFeb 15, 2018
    risk 0.53cvss 8.1epss 0.02

    An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections.

  • CVE-2017-12726HigFeb 15, 2018
    risk 0.48cvss 7.3epss 0.01

    A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths…

  • CVE-2017-12721MedFeb 15, 2018
    risk 0.38cvss 5.9epss 0.01

    An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle (MITM) attack.

  • CVE-2017-12725MedFeb 15, 2018
    risk 0.36cvss 5.6epss 0.01

    A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The…

  • CVE-2017-12722MedFeb 15, 2018
    risk 0.35cvss 5.3epss 0.02

    An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that…

  • CVE-2017-12723LowFeb 15, 2018
    risk 0.24cvss 3.7epss 0.01

    A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external…