VYPR

IntelliVue Patient Monitors MX (MX400-550)

by Philips

CVEs (5)

  • CVE-2018-10601HigJun 5, 2018
    risk 0.53cvss 8.2epss 0.00

    IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have…

  • CVE-2017-9658MedApr 30, 2018
    risk 0.42cvss 6.5epss 0.01

    Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access…

  • CVE-2017-9657MedApr 30, 2018
    risk 0.42cvss 6.5epss 0.01

    Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring station is possible. In this state, the central monitoring station can indicate the MX40 is not connected or associated to the…

  • CVE-2020-16216Sep 11, 2020
    risk 0.00cvss epss 0.01

    In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process…

  • CVE-2020-16228Sep 11, 2020
    risk 0.00cvss epss 0.00

    In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation …