CVEs (5)
| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2023-46141 | Cri | 0.64 | 9.8 | 0.01 | Dec 14, 2023 | Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device. | ||
| CVE-2022-3737 | Hig | 0.51 | 7.8 | 0.00 | Nov 15, 2022 | In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to insufficient validation of input data. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks… | ||
| CVE-2022-3461 | Hig | 0.51 | 7.8 | 0.00 | Nov 15, 2022 | In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ files could lead to a heap buffer overflow and a read access violation. Availability, integrity, or confidentiality of an application programming workstation might be compromised… | ||
| CVE-2021-33542 | Hig | 0.51 | 7.8 | 0.02 | Jun 25, 2021 | Phoenix Contact Classic Automation Worx Software Suite in Version 1.87 and below is affected by a remote code execution vulnerability. Manipulated PC Worx or Config+ projects could lead to a remote code execution when unallocated memory is freed because of incompletely… | ||
| CVE-2023-46143 | Hig | 0.49 | 7.5 | 0.00 | Dec 14, 2023 | Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC. |
- risk 0.64cvss 9.8epss 0.01
Incorrect Permission Assignment for Critical Resource vulnerability in multiple products of the PHOENIX CONTACT classic line allow an remote unauthenticated attacker to gain full access of the affected device.
- risk 0.51cvss 7.8epss 0.00
In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 memory can be read beyond the intended scope due to insufficient validation of input data. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks…
- risk 0.51cvss 7.8epss 0.00
In PHOENIX CONTACT Automationworx Software Suite up to version 1.89 manipulated PC Worx or Config+ files could lead to a heap buffer overflow and a read access violation. Availability, integrity, or confidentiality of an application programming workstation might be compromised…
- risk 0.51cvss 7.8epss 0.02
Phoenix Contact Classic Automation Worx Software Suite in Version 1.87 and below is affected by a remote code execution vulnerability. Manipulated PC Worx or Config+ projects could lead to a remote code execution when unallocated memory is freed because of incompletely…
- risk 0.49cvss 7.5epss 0.00
Download of Code Without Integrity Check vulnerability in PHOENIX CONTACT classic line PLCs allows an unauthenticated remote attacker to modify some or all applications on a PLC.