CVE-2019-13940
Description
A vulnerability has been identified in SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.X.17), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.1), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX 2010 (All versions), SIMATIC WinAC RTX F 2010 (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.X.17), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.X.17), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.X.17). Affected devices contain a vulnerability that could cause a denial of service condition of the web server by sending specially crafted HTTP requests to ports 80/tcp and 443/tcp.
Beyond the web service, no other functions or interfaces are affected by the denial of service condition.
Affected products
27- Siemens/SIMATIC ET 200pro IM154-8F PN/DP CPUv5Range: All versions < V3.X.17
- Siemens/SIMATIC ET 200pro IM154-8FX PN/DP CPUv5Range: All versions < V3.X.17
- Siemens/SIMATIC ET 200pro IM154-8 PN/DP CPUv5Range: All versions < V3.X.17
- Siemens/SIMATIC ET 200S IM151-8F PN/DP CPUv5Range: All versions < V3.X.17
- Siemens/SIMATIC ET 200S IM151-8 PN/DP CPUv5Range: All versions < V3.X.17
- Range: All versions < V4.1
All versions < V3.X.17+ 4 more
- (no CPE)range: All versions < V3.X.17
- (no CPE)range: All versions < V3.X.17
- (no CPE)range: All versions < V3.X.17
- (no CPE)range: All versions < V3.X.17
- (no CPE)range: All versions < V3.X.17
All versions < V3.X.17+ 4 more
- (no CPE)range: All versions < V3.X.17
- (no CPE)range: All versions < V3.X.17
- (no CPE)range: All versions < V3.X.17
- (no CPE)range: All versions < V3.X.17
- (no CPE)range: All versions < V3.X.17
- Siemens/SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)v5Range: All versions
- Siemens/SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)v5Range: All versions
- Range: All versions
- Range: All versions
- Siemens/SIPLUS ET 200S IM151-8F PN/DP CPUv5Range: All versions < V3.X.17
- Siemens/SIPLUS ET 200S IM151-8 PN/DP CPUv5Range: All versions < V3.X.17
- Siemens/SIPLUS S7-300 CPU 314C-2 PN/DPv5Range: All versions < V3.X.17
- Siemens/SIPLUS S7-300 CPU 315-2 PN/DPv5Range: All versions < V3.X.17
- Siemens/SIPLUS S7-300 CPU 315F-2 PN/DPv5Range: All versions < V3.X.17
- Siemens/SIPLUS S7-300 CPU 317-2 PN/DPv5Range: All versions < V3.X.17
- Siemens/SIPLUS S7-300 CPU 317F-2 PN/DPv5Range: All versions < V3.X.17
Patches
0No patches discovered yet.
Vulnerability mechanics
AI mechanics synthesis has not run for this CVE yet.
References
1News mentions
0No linked articles in our index yet.