4| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2026-34184 | Cri | 0.59 | 9.1 | 0.00 | Apr 9, 2026 | Hydrosystem Control System does not enforce authorization for some directories. This allows an unauthorized attacker to read all files in these directories and even execute some of them. Critically the attacker could run PHP scripts directly on the connected database.This issue… | ||
| CVE-2026-34185 | Hig | 0.57 | 8.8 | 0.00 | Apr 9, 2026 | Hydrosystem Control System is vulnerable to SQL Injection across most scripts and input parameters. Because no protections are in place, an authenticated attacker can inject arbitrary SQL commands, potentially gaining full control over the database.This issue was fixed in… | ||
| CVE-2026-4901 | Med | 0.42 | 6.5 | 0.00 | Apr 9, 2026 | Hydrosystem Control System saves sensitive information into a log file. Critically, user credentials are logged allowing the attacker to obtain further authorized access into the system. Combined with vulnerability CVE-2026-34184, these sensitive information could be accessed by… | ||
| CVE-2023-0580 | 0.00 | — | 0.00 | Apr 6, 2023 | Insecure Storage of Sensitive Information vulnerability in ABB My Control System (on-premise) allows an attacker who successfully exploited this vulnerability to gain access to the secure application data or take control of the application. Of the services that make up the My… |
- risk 0.59cvss 9.1epss 0.00
Hydrosystem Control System does not enforce authorization for some directories. This allows an unauthorized attacker to read all files in these directories and even execute some of them. Critically the attacker could run PHP scripts directly on the connected database.This issue…
- risk 0.57cvss 8.8epss 0.00
Hydrosystem Control System is vulnerable to SQL Injection across most scripts and input parameters. Because no protections are in place, an authenticated attacker can inject arbitrary SQL commands, potentially gaining full control over the database.This issue was fixed in…
- risk 0.42cvss 6.5epss 0.00
Hydrosystem Control System saves sensitive information into a log file. Critically, user credentials are logged allowing the attacker to obtain further authorized access into the system. Combined with vulnerability CVE-2026-34184, these sensitive information could be accessed by…
- CVE-2023-0580Apr 6, 2023risk 0.00cvss —epss 0.00
Insecure Storage of Sensitive Information vulnerability in ABB My Control System (on-premise) allows an attacker who successfully exploited this vulnerability to gain access to the secure application data or take control of the application. Of the services that make up the My…