Circl
Products
15- 14 CVEs
- 12 CVEs
- 12 CVEs
- 6 CVEs
- 4 CVEs
- 2 CVEs
- 2 CVEs
- 2 CVEs
- 2 CVEs
- 2 CVEs
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
- 1 CVE
Recent CVEs
29| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2024-8888 | Cri | 0.65 | 10.0 | 0.00 | Sep 18, 2024 | An attacker with access to the network where CIRCUTOR Q-SMT is located in its firmware version 1.0.4, could steal the tokens used on the web, since these have no expiration date to access the web application without restrictions. Token theft can originate from different methods… | ||
| CVE-2024-8887 | Cri | 0.65 | 10.0 | 0.01 | Sep 18, 2024 | CIRCUTOR Q-SMT in its firmware version 1.0.4, could be affected by a denial of service (DoS) attack if an attacker with access to the web service bypasses the authentication mechanisms on the login page, allowing the attacker to use all the functionalities implemented at web… | ||
| CVE-2021-33841 | Cri | 0.65 | 10.0 | 0.02 | Jun 9, 2021 | SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges. | ||
| CVE-2025-11788 | Cri | 0.64 | 9.8 | 0.00 | Dec 2, 2025 | Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowSupervisorParameters()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input,… | ||
| CVE-2025-11786 | Cri | 0.64 | 9.8 | 0.00 | Dec 2, 2025 | Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'SetUserPassword()' function, the 'newPassword' parameter is directly embedded in a shell command string using 'sprintf()' without any sanitisation or validation, and then executed using… | ||
| CVE-2025-11785 | Cri | 0.64 | 9.8 | 0.00 | Dec 2, 2025 | Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which… | ||
| CVE-2025-11784 | Cri | 0.64 | 9.8 | 0.00 | Dec 2, 2025 | Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which… | ||
| CVE-2025-11783 | Cri | 0.64 | 9.8 | 0.01 | Dec 2, 2025 | Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The vulnerability is found in the 'AddEvent()' function when copying the user-controlled username input to a fixed-size buffer (48 bytes) without boundary checking. This can lead to memory… | ||
| CVE-2025-11782 | Cri | 0.64 | 9.8 | 0.00 | Dec 2, 2025 | Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'ShowDownload()' function uses “sprintf()” to format a string that includes the user-controlled input of 'GetParameter(meter)' in the fixed-size buffer 'acStack_4c' (64 bytes) without… | ||
| CVE-2025-11780 | Cri | 0.64 | 9.8 | 0.00 | Dec 2, 2025 | Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is… | ||
| CVE-2025-11779 | Cri | 0.64 | 9.8 | 0.01 | Dec 2, 2025 | Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The 'SetLan' function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes… | ||
| CVE-2025-11778 | Cri | 0.64 | 9.8 | 0.00 | Dec 2, 2025 | Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely exploit memory corruption through the 'read_packet()' function of the TACACSPLUS implementation. | ||
| CVE-2021-26777 | Cri | 0.64 | 9.8 | 0.02 | Dec 2, 2021 | Buffer overflow vulnerability in function SetFirewall in index.cgi in CIRCUTOR COMPACT DC-S BASIC smart metering concentrator Firwmare version CIR_CDC_v1.2.17, allows attackers to execute arbitrary code. | ||
| CVE-2025-64385 | Cri | 0.60 | — | 0.00 | Oct 31, 2025 | The equipment initially can be configured using the manufacturer's application, by Wi-Fi, by the web server or with the manufacturer’s software. Using the manufacturer's software, the device can be configured via UDP. Analyzing this communication, it has been observed that any… | ||
| CVE-2024-8889 | Cri | 0.60 | 9.3 | 0.00 | Sep 18, 2024 | Vulnerability in CIRCUTOR TCP2RS+ firmware version 1.3b, which could allow an attacker to modify any configuration value, even if the device has the user/password authentication option enabled, without authentication by sending packets through the UDP protocol and port 2000,… | ||
| CVE-2025-11787 | Hig | 0.57 | 8.8 | 0.01 | Dec 2, 2025 | Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the 'GetDNS()', 'CheckPing()' and 'TraceRoute()' functions. | ||
| CVE-2021-33842 | Hig | 0.57 | 8.8 | 0.00 | Jun 9, 2021 | Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device… | ||
| CVE-2025-42615 | Hig | 0.53 | — | 0.00 | Dec 8, 2025 | In affected versions, vulnerability-lookup did not track or limit failed One-Time Password (OTP) attempts during Two-Factor Authentication (2FA) verification. An attacker who already knew or guessed a valid username and password could submit an arbitrary number of OTP codes… | ||
| CVE-2024-8890 | Hig | 0.52 | 8.0 | 0.00 | Sep 18, 2024 | An attacker with access to the network where the CIRCUTOR Q-SMT is located in its firmware version 1.0.4, could obtain legitimate credentials or steal sessions due to the fact that the device only implements the HTTP protocol. This fact prevents a secure communication channel… | ||
| CVE-2025-11781 | Hig | 0.51 | 7.8 | 0.00 | Dec 2, 2025 | Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. An attacker with local access to the device can extract this key (e.g., by analysing the firmware image or memory dump) and create… |
- risk 0.65cvss 10.0epss 0.00
An attacker with access to the network where CIRCUTOR Q-SMT is located in its firmware version 1.0.4, could steal the tokens used on the web, since these have no expiration date to access the web application without restrictions. Token theft can originate from different methods…
- risk 0.65cvss 10.0epss 0.01
CIRCUTOR Q-SMT in its firmware version 1.0.4, could be affected by a denial of service (DoS) attack if an attacker with access to the web service bypasses the authentication mechanisms on the login page, allowing the attacker to use all the functionalities implemented at web…
- risk 0.65cvss 10.0epss 0.02
SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker to inject code into the operating system with maximum privileges.
- risk 0.64cvss 9.8epss 0.00
Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowSupervisorParameters()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input,…
- risk 0.64cvss 9.8epss 0.00
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'SetUserPassword()' function, the 'newPassword' parameter is directly embedded in a shell command string using 'sprintf()' without any sanitisation or validation, and then executed using…
- risk 0.64cvss 9.8epss 0.00
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which…
- risk 0.64cvss 9.8epss 0.00
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which…
- risk 0.64cvss 9.8epss 0.01
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The vulnerability is found in the 'AddEvent()' function when copying the user-controlled username input to a fixed-size buffer (48 bytes) without boundary checking. This can lead to memory…
- risk 0.64cvss 9.8epss 0.00
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'ShowDownload()' function uses “sprintf()” to format a string that includes the user-controlled input of 'GetParameter(meter)' in the fixed-size buffer 'acStack_4c' (64 bytes) without…
- risk 0.64cvss 9.8epss 0.00
Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is…
- risk 0.64cvss 9.8epss 0.01
Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The 'SetLan' function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes…
- risk 0.64cvss 9.8epss 0.00
Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely exploit memory corruption through the 'read_packet()' function of the TACACSPLUS implementation.
- risk 0.64cvss 9.8epss 0.02
Buffer overflow vulnerability in function SetFirewall in index.cgi in CIRCUTOR COMPACT DC-S BASIC smart metering concentrator Firwmare version CIR_CDC_v1.2.17, allows attackers to execute arbitrary code.
- risk 0.60cvss —epss 0.00
The equipment initially can be configured using the manufacturer's application, by Wi-Fi, by the web server or with the manufacturer’s software. Using the manufacturer's software, the device can be configured via UDP. Analyzing this communication, it has been observed that any…
- risk 0.60cvss 9.3epss 0.00
Vulnerability in CIRCUTOR TCP2RS+ firmware version 1.3b, which could allow an attacker to modify any configuration value, even if the device has the user/password authentication option enabled, without authentication by sending packets through the UDP protocol and port 2000,…
- risk 0.57cvss 8.8epss 0.01
Command injection vulnerability in the operating system in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2 through the 'GetDNS()', 'CheckPing()' and 'TraceRoute()' functions.
- risk 0.57cvss 8.8epss 0.00
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device…
- risk 0.53cvss —epss 0.00
In affected versions, vulnerability-lookup did not track or limit failed One-Time Password (OTP) attempts during Two-Factor Authentication (2FA) verification. An attacker who already knew or guessed a valid username and password could submit an arbitrary number of OTP codes…
- risk 0.52cvss 8.0epss 0.00
An attacker with access to the network where the CIRCUTOR Q-SMT is located in its firmware version 1.0.4, could obtain legitimate credentials or steal sessions due to the fact that the device only implements the HTTP protocol. This fact prevents a secure communication channel…
- risk 0.51cvss 7.8epss 0.00
Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. An attacker with local access to the device can extract this key (e.g., by analysing the firmware image or memory dump) and create…